KFD and KFND stainless steel gas-liquid mixing pump model meaning:

Overview of KFD and KFND stainless steel gas-liquid mixing pumps:
The suction port of the gas-liquid mixing pump can use negative pressure to suck in gas, so there is no need to use an air compressor and atmospheric injector. The high-speed rotating pump impeller mixes and stirs the liquid and gas, so there is no need for a stirrer or mixer. Due to the pressurized mixing inside the pump, the gas and liquid are fully dissolved, and the dissolution efficiency can reach 80-100%. So there is no need for large pressurized gas tanks or expensive reaction towers to produce highly soluble solutions. The gas-liquid ratio is approximately 1:9 (with a suction capacity of 8-10%), and using it in series can increase the suction capacity. A gas-liquid mixing pump can perform gas-liquid suction, mixing, dissolution, and directly deliver highly dissolved liquid to the point of use. Pump flow rate 1-50 M3/H; Processing water volume 1-150 M3/H. Therefore, using a gas-liquid mixing pump can improve the efficiency of dissolved gas-liquid production, simplify the production equipment, save space, significantly reduce initial investment, and save operating and maintenance costs.
Structure diagram of KFD and KFND stainless steel gas-liquid mixing pump:
|
|
| ||||
| serial number | Part Name | quantity | KFD | KFND | |
| 049 | Shaft seal fastening ring | 1 | 304 | ||
| 051 | mechanical seal | 1 | Silicon carbide X Silicon carbide | ||
| 081 | water retaining ring | 1 | Nitrile rubber | ||
| 102 | pump body | 1 | 304 | ||
| 103 | pump cover | 1 | 304 | ||
| 107 | impeller | 1 | 304 | ||
| 116 | key | 1 | 304 | ||
| 118 | Paired flange for spout outlet | 1 | 304 | ||
| 123 | o-ring | 1 | teflon | ||
| 124 | Discharge gasket | 1 | Resin rubber | ||
| 135 | embolism | 1 | 304 | ||
| 164 | Tighten the screws | 2 | 304 | ||
| 500 | motor | 1 | Axis material 304 | ||
Performance parameters of KFD and KFND stainless steel gas-liquid mixing pumps:
| model | Equipped with motor | H (m) | 10 | 20 | 30 | 40 | 50 | 60 | 70 | |
| power(KW) | phase number | |||||||||
| 20KFD-1 | 0.75 | Single phase, three-phase | Q (m3/h) | 2.8 | 2.2 | 1.6 | 1 | 0.4 |
|
|
| 20KFDB-1 | three-phase | |||||||||
| 25KFD-2 | 1.1 | Single phase, three-phase | 3.5 | 2.8 | 2.5 | 2 | 1.6 | 1 |
| |
| 25KFDB-2 | three-phase | |||||||||
| 40KFD-6 | 3 | three-phase | 8 | 7.5 | 6.5 | 6 | 5.5 | 4.5 | 3.5 | |
| 40KFDB-6 | 4 | |||||||||
| 50KFD-12 | 5.5 | three-phase | 18 | 16 | 15 | 14 | 12 | 10 | 7.5 | |
| 50KFDB-12 | 7.5 | |||||||||
| 20KFDL-1 | 0.55 | Single phase, three-phase | Q (m3/h) | 2.8 | 2.2 | 1.6 | 1 | 0.4 |
|
|
| 20KFDLB-1 | three-phase | |||||||||
| 25KFDL-2 | 1.1 | Single phase, three-phase | 3.5 | 2.8 | 2.5 | 2 | 1.6 | 1 |
| |
| 25KFDLB-2 | three-phase | |||||||||
| 40KFDL-6 | 4 | three-phase | 8 | 7.5 | 6.5 | 6 | 5.5 | 4.5 | 3.5 | |
| 40KFDLB-6 | ||||||||||
| 50KFDL-11 | 7.5 | three-phase | 18 | 16 | 15 | 14 | 12 | 10 | 7.5 | |
| 50KFDBL-11 | ||||||||||
Characteristics of KFD and KFND stainless steel gas-liquid mixing pumps:
1. Exquisite volume and high performance, achieving miniaturization of industrial equipment.
2. The combination of components made of ultra precision materials is suitable for a wide range of liquids and applications, with low corrosion resistance and low NPSH margin, and stable performance without liquid leakage.
3. There is no mechanical friction inside the pump except for the contact surface of the mechanical shaft seal, and the performance remains stable for a long time without failure.
4. Low noise, long lifespan, greatly improving the reliability of the device.
5. On site maintenance is easy to operate and maximizes the protection of user interests.
KFD and KFND stainless steel gas-liquid mixing pumps are equipped with YE2 rate three-phase asynchronous motors:
| Motor specifications | model | Fully enclosed exterior fan-shaped interior | |||||
| power | 0.55 | 0.75 | 1.5 | 2.2 | 3 | 4 | |
| rated value | series | 4P | |||||
| protection method | IP55 | ||||||
| insulation class | Grade E | ||||||
| Surrounding conditions | Setting up a venue | indoor | |||||
| ambient temperature | -20 ℃ to 40 ℃ | ||||||
| ambient humidity | below 85% | ||||||
| Environmental atmosphere | No corrosive, explosive gases or vapors | ||||||
Performance characteristics of KFD and KFND stainless steel gas-liquid mixing pumps:
| model | KFD | KFND |
| connection method | Flange JIS5K | Rc screw mouth |
| characteristic | Self suction -8m (20 ℃) | Ultra low NPSH |
| Suitable for liquids | Water, pure water, chemical liquids, oily liquids, pharmaceuticals, solvents, refrigerants | |
| temperature range | Water and chemical solution:~90 ℃; Refrigerant: -30 ℃ | |
| Standard motor (50HZ) | Z: 3-phase fully enclosed outdoor fan indoor form 4P/380V · 220V | |
Product pictures of KFD and KFND stainless steel gas-liquid mixing pumps:

316L self-priming gas-liquid mixing pump
Last Article: Can I introduce you to multi-stage centrifugal pumps?