1. Motor category: electric vehicle motors, electric vehicle controllers, DC motor testing, aging and debugging, etc 2. Electrical appliances: LED/LCD testing and aging, energy-saving bulb testing and aging, lighting fixture testing, tungsten wire gasification, etc 3. Automotive category: starter motor, automotive air conditioning, automotive motor controller, automotive lighting, cigarette lighter, automotive audio and video testing and aging, etc 4. Electronic components: capacitors, resistors, relays, transistors, sensors, etc 5. Display type: Display screen, liquid dispenser screen, touch screen, car DVD, mobile phone display, etc 6. Electrochemistry: electrolysis, electroplating, anodizing, non-ferrous metals, wastewater treatment, etc 7. Military aviation: aircraft start-up maintenance, power supply for military equipment, etc 8. Exploration category: Power supply for petroleum equipment and electrical instruments, etc 9. Power supply category: aging of inverter products, maintenance and testing of frequency converters, etc 10. Electric tools: contact aging, wire package testing, circuit breaker trip test, etc 11. New energy category: photovoltaic inverter testing, electric vehicle motor testing, lithium battery charging, etc 12. High end scientific research categories: magnetic field power supply, superconducting experiments, ion accelerators, etc;
|
The output characteristics are controlled by a high-speed CPU; 19 inch standard U-shaped chassis; Adopting the wide range ZVZCS soft switching transformation technology with independent intellectual property rights, it has high efficiency and reliability; ■ Modular design of power supply, with N+m parallel redundancy structure, greatly reducing failure rate and good stability; ■ Equipped with high-precision voltage and current measurement, and four digit LED display; High precision, low ripple, low noise, fast response time; Pre set overvoltage protection value and overcurrent protection value; Simple numeric keypad and function button operation, easy to operate; ■ It has the functions of input phase loss, input overvoltage and undervoltage, output overvoltage, overpower, over temperature, and short circuit protection; ■ It has constant voltage and constant current mode output, and can automatically cross transform; Standard RS485/RS232/GPIB communication interfaces and Modhus RTU communication protocol; Standard upper computer software, providing rich expansion functions; Support remote voltage compensation to reduce line voltage drop losses;
|
|
model
|
NHWYSseries
|
|
Input power supply system
|
Single phase 220V/Three phase 380V; Frequency: 50/60/400HZ
|
|
Output external characteristics
|
Constant voltageCV &Constant currentCC&Constant power CP
|
|
working method
|
ZVZCS+PWMswitch type
|
|
input
|
phase number
|
Single phase 2Φ2W+ PE/threeXiang3Φ4W+ PE
|
|
Input voltage range
|
single-phase220V±15%Or three-phase380V/400V±15%
|
|
frequency
|
47-63HZ
|
|
power factor
|
> 0. 9
|
|
inrush current
|
None, soft start
|
|
output
|
output voltage
|
output current
|
|
0-5VDC
|
100A
|
200A
|
300A
|
500A
|
1000A
|
|
0-15VDC
|
50A
|
100A
|
300A
|
800A
|
1000A
|
|
0-30VDC
|
30A
|
50A
|
100A
|
300A
|
500A
|
|
0-60VDC
|
10A
|
30A
|
50A
|
100A
|
300A
|
|
0-80VDC
|
10A
|
30A
|
60A
|
100A
|
300A
|
|
0-100VDC
|
10A
|
30A
|
50A
|
200A
|
300A
|
|
0-150VDC
|
10A
|
30A
|
50A
|
100A
|
200A
|
|
0-200VDC
|
10A
|
30A
|
50A
|
100A
|
200A
|
|
0-300VDC
|
20A
|
40A
|
60A
|
80A
|
100A
|
|
0600VDC
|
10A
|
20A
|
30A
|
40A
|
50A
|
|
0-1000VDC
|
6 A
|
12A
|
18A
|
24A
|
30A
|
|
efficiency
|
>95%(Standard communication input, full load)
|
|
Power regulation rate
|
<±0.2% @ FS
|
|
loadAdjustment rate
|
<1% @ FS
|
|
Load transient recovery time
|
<5mS
|
|
voltage accuracy
|
≤±0.5%(Reading)+Range)
|
|
current accuracy
|
≤±0.5%(Reading)+Range)
|
|
ripple
|
<0.5% @FS (fully loaded)
|
|
overcurrent
|
Maximum current cutoff and maximum power control
|
|
digital display
|
voltmetermeasurement accuracy
|
4位半LEDDisplay specifications:0.5%@FS+ 5digit
|
|
voltmeterresolution
|
Vo<1000V :0.1V Vo≥1000V :1V
|
|
ammetermeasurement accuracy
|
4位半LEDDisplay specifications:0.5%@FS+ 5digit
|
|
Resolution of ammeter
|
output100A>Io≥10A: 0.01A
output1000A>Io≥100A: 0.1AoutputIo≥1000A: 1A
|
|
working conditions
|
temperature
|
Storage temperature:-15℃~+50℃ Operating Temperature: -10℃~+40℃
|
|
relative humidity
|
≤95%(No condensation)
|
|
Protection level
|
IP20
|
|
atmospheric pressure
|
80~106KPc(altitude)2000mBelow)
|
|
noise
|
< 65 dB@ 1 rice
|
|
protect
|
Input phase loss protection, input overvoltage protection, input undervoltage protection, output overvoltage protection, output overcurrent protection, short circuit protection, overheating protection;
|
IGBT is a power conversion device and the core of a power supply. It can be damaged by overvoltage, overcurrent, overheating, oscillation, and interference in the power supply. IGBT overvoltage protection includes: ① Di/dt, dv/dt buffer protection; ② High voltage sharp pulse protection; ③ Overcurrent protection, specific indicators are as follows: a. When di/dt>20A/μ s and di/dt>800V/μ s, the IGBT enters the 3 μ s pulse width limit protection, and the power supply instantly decreases without stopping working or alarming; b. When the high-voltage peak pulse voltage reaches 860Vp-p (IGBT withstand voltage 1200V), the peak voltage is suppressed; c. When IGBT overcurrent occurs for some reason and IGBT VCE ≥ 6.8V, IGBT enters 3 μ s pulse width limit protection, the power supply does not stop working, and there is no alarm. When IGBT VCE ≥ 7V, IGBT enters cutoff protection, the power supply stops working, and the alarm displays IGBT fault.
|
|
cooling system
|
Forced fan cooling
|
|
communication interface
|
RS232/RS485/Signal dry contacts provide corresponding Modbus communication protocol
|
|
volume
|
600 * 600 * 1400mm (width * depth * height)
|
|
weight
|
About 160Kg
|
Model
|