AMD-I (Z) type electromagnetic pulse valve is a right angle valve

NegotiableUpdate on 01/29
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The AMD-I (Z) electromagnetic pulse valve produced by Chuangxin Dust Removal Company is a right angle valve with an inlet and outlet angle of 90 °, suitable for installation and connection between the air bag and the dust collector spray pipe. Smooth airflow, clear ash pulse. Electromagnetic pulse valve is the compressed air "switch" of the pulse bag filter dust cleaning and spraying system.
Product Details

Produced by Chuangxin Dust Removal CompanyAMD-I (Z) type electromagnetic pulse valve is a right angle valveThe angle between its inlet and outlet is 90 °, which is suitable for the installation and connection of the air bag and the dust collector spray pipe. Smooth airflow, clear ash pulse.
Electromagnetic pulse valve is the compressed air "switch" of the pulse bag filter dust cleaning and spraying system. Under the control of the output signal from the pulse jet control instrument, the filter bags are blown clean one by one to maintain the resistance of the dust collector within the set range, in order to improve the processing capacity and dust collection efficiency of the dust collector.
Connect clean air with a nominal pressure to the inlet of the electromagnetic pulse valve, input an electrical signal with a width of 0.03s and a nominal voltage of 85% to the electromagnetic valve, and check if the electromagnetic pulse valve opens normally.
(2) Close the air pressure test
Connect clean air with a pressure of 0.1MPa to the inlet of the electromagnetic pulse valve, input an electrical signal to close the valve, and check whether the electromagnetic pulse valve is reliably closed.
(3) Voltage resistance performance test
Connect clean air with a pressure of 0.8MPa to the inlet of the electromagnetic pulse valve for 60 minutes, and check the leakage of air from various sealing parts on the electromagnetic pulse valve.