E-mail
sale@hardnesstestersh.com
- Phone
-
Address
No. E1, Lane 288, Yuyang Road, Songjiang District, Shanghai
Shanghai Aolong Xingdi Testing Equipment Co., Ltd
sale@hardnesstestersh.com
No. E1, Lane 288, Yuyang Road, Songjiang District, Shanghai
Product Introduction
AT3100Featuring a unique temperature compensation algorithm that supports10Multiple calibration modes, including point based calibration, temperature calibration, zero point calibration, and two-point calibration, are used to measure the thickness of non-magnetic coatings on magnetic metal substrates using both magnetic and eddy current side thickness methods
The thickness of the non-conductive coating on the substrate;
Split (sensor and instrument connected by leads), dual-use(FType andNType in one);
There are two measurement methods: continuous measurement method(CONTINUE)And single measurement method(SINGLE);
There are five statistical values: mean, maximum, minimum, number of measurements, and standard deviation;
There are two working modes, direct mode and composition mode;
There are two methods to calibrate the instrument, and basic calibration can be used to correct the system error of the measuring head;
Has storage function, can store500A measurement value;
It has a deletion function to delete individual suspicious data that appears during measurement, as well as to delete all stored data for the purpose of conducting new measurements;
Limits can be set, and automatic alarms can be triggered for measurement values outside the limits;
It can display the battery level in real time, with a beep sound during operation, and can choose to turn off the buzzer;
The standby time is adjustable, and it will automatically shut down after exceeding the standby time;
Adjustable screen contrast;
It has an error prompt function, which provides error prompts through screen display or buzzer sound;
There are two shutdown modes, manual shutdown and automatic shutdown;
Technical Specifications
|
Product Model |
AT3100 |
|
measurement range |
0-1250um(steel). |
|
resolution |
0.1um(0-50um),1um(>50um) |
|
measurement error |
3%H+1um(HFor the measurement range) |
|
Minimum Curvature radius |
1.5mm(FType)3mm(NType) |
|
Minimum critical thickness |
0.5mm(FType)0.3mm(NType) |
|
Minimum matrix diameter |
7mm(FType)5mm(NType) |
|
probe type |
FTypeNType split probe |
|
Function alarm |
Limits can be set, and automatic beeping alarms can be triggered for measurement values outside the limits |
|
Working Voltage |
3*1.5V |
|
Overall dimensions |
155×68×27mm |
|
Total weight |
230g |