The HC series rotary aerator produced by our factory is a professional aeration fan used in sewage pumping stations. The aeration fan contains Japanese technology and hasSmall size, high air volume, low noise, low energy consumption, smooth operation, easy installation, minimal malfunctions, long lifespanSuch characteristics. The installation of aeration fans for this pump station model can refer to the general mechanical equipment installation specifications. In addition, the following items should be noted: 1 :During installation, use a spirit level to calibrate the level, and use secondary grouting method for the foot screw mouth. |

|
1 The temperature of the imported gas shall not exceed 40 ℃. 2 The bearing temperature shall not exceed 95 ℃. 3 The temperature of the lubricating oil should not exceed 65 ℃. 4 The rotation direction of the electric motor is consistent with the standard rotation direction of the fan. 5 Inject engine oil into the fuel tank until the oil level line is reached. Lubricating oil varies with seasonal temperature changes. It is recommended to use N32 lubricating oil in summer and N10 lubricating oil in winter. 6 The blower is running at no load 1】 Newly installed or overhauled fans must operate at no load. 2】 The concept of no-load operation is to put it into operation with all inlet and outlet valves open. 3】 During the trial operation, pay attention to observing that the oil nozzles at both ends of the lubricating oil are normal. If there is too much or too little, adjust the ink (15-20 points per minute). 4】 There is no abnormal odor, smoking phenomenon, or collision friction sound. 5】 Run under no-load for about 20 minutes, the situation is normal, and it can be put into operation with load. If any abnormality is found, it should be checked and after troubleshooting, it still needs to go through no-load operation. 6】 During normal operation of the fan, it is strictly prohibited to completely close the exhaust valve or operate it at overload. The safe operation and service life of rotary fans depend on proper and regular maintenance, and attention should be paid to any potential faults. |

Technical parameters of rotary aerator fan
| model | exhaust |
motor power (kw) |
frequency |
fan |
Airflow (m3/min) | V-belt pulley |
V-shaped belt |
Fuel tank storage fuel level (Effective fuel quantity) |
Weight (kg) |
||||||
0.1kgf |
0.2kgf |
0.3kgf |
0.4kgf /cm2 |
0.5kgf |
blower | motor | net weight |
hair volume |
|||||||
HC-120S |
3/4'(20) | 0.25 |
50 | 450 | 0.12 | 0.115 | 0.110 | 0.105 | 0.100 | 6” |
11/2' | A-40 |
2.0L(1.5L) |
35 |
38 |
HC-150S |
3/4'(20) |
0.25 |
50 | 580 |
0.156 |
0.150 | 0.145 |
0.140 |
0.138 |
6” |
2' |
A-40 |
2.0L(1.5L) | 35 |
38 |
HC-200S |
3/4'(20) | 0.37 |
50 | 680 |
0.210 |
0.205 |
0.200 | 0.195 | 0.190 | 6' | 2' | A-40 |
2.0L(1.5L) | 38 |
41 |
HC-251S |
3/4'(20) | 0.55 | 50 | 450 |
0.31 | 0.30 | 0.29 |
0.28 | 0.28 |
8' |
21/2' |
A-40 |
1.5L(1.1L) |
44 |
51 |
HC-30S |
1'(25) |
0.55 | 50 | 430 | 0.35 |
0.34 |
0.33 |
0.32 |
0.31 |
10' |
3' |
A-44 |
1.5L(1.1L) |
50 |
57 |
HC-301S |
1'(25) | 0.75 | 50 | 520 | 0.42 |
0.41 | 0.4 |
0.39 |
0.38 |
10' |
31/2' |
A-44 |
1.5L(1.1L) |
50 |
57 |
HC-40S |
11/4'(32) | 0.75 |
50 | 500 | 0.66 | 0.65 |
0.63 |
0.61 |
0.59 | 12' |
4' |
A-52 |
2.5L(1.7L) |
80 |
88 |
| HC-401S | 11/4'(32) | 1.5 |
50 | 580 | 0.8 |
0.77 | 0.74 |
0.71 |
0.67 |
12' |
41/2' |
A-52 |
2.5L(1.7L) |
85 | 93 |
HC-50S |
11/2'(40) | 1.5 |
50 | 430 | 1.14 |
1.12 |
1.09 |
1.06 |
1.02 |
14' |
4' |
A-64 |
3.5L(2.3L) | 120 |
130 |
HC-501S |
11/2'(40) | 2.2 |
50 | 500 | 1.44 |
1.42 |
1.39 |
1.36 | 1.32 |
14' |
41/2' |
A-64 |
3.5L(2.3L) |
125 | 135 |
HC-60S |
2'(50) | 2.2 | 50 | 450 | 1.9 |
1.87 | 1.82 |
1.77 | 1.71 |
16' |
5' |
B-74 |
5.5L(3.8L) | 190 | 223 |
HC-601S |
2'(50) | 4 | 50 | 540 | 2.41 | 2.34 | 2.29 | 2.24 | 2.18 | 16' | 6' | B-74 | 5.5L(3.8L) | 200 | 233 |
HC-80S |
21/2'(65) | 4 | 50 | 430 | 2.82 | 2.74 | 2.66 | 2.59 | 2.5 | 18' | 51/2 | B-84 | 8L(6L) |
250 | 268 |
HC-801S |
21/2'(65) | 5.5 | 50 | 500 | 3.53 | 3.45 | 3.38 | 3.33 | 3.25 | 18' | 6' | B-84 | 8L(6L) | 275 | 293 |
HC-100S |
3'(80) | 5.5 | 50 | 390 | 4.32 | 4.28 | 4.25 | 4.18 | 4.11 | 20' | 51/2' | B-93 | 20L(16L) | 375 | 395 |
HC-1001S |
3'(80) | 7.5 | 50 | 420 | 5.41 | 5.32 | 5.25 | 5.18 | 5.11 | 20' | 6' | B-93 | 20L(16L) | 390 | 410 |
HC-125A |
4'(100) |
7.5 |
50 |
390 |
6.87 |
6.82 |
6.78 |
6.63 |
6.58 |
20' |
6' |
B-93 |
30L(25L) |
580 |
600 |
HC-125B |
4'(100) |
11 |
50 |
420 |
7.83 |
7.81 |
7.78 |
7.75 |
7.72 |
20' |
6' |
B-93 |
30L(25L) |
600 |
620 |
HC-125C |
4'(100) |
11 |
50 |
500 |
9.20 |
9.10 |
9.0 |
8.80 |
8.70 |
20' |
6' |
B-93 |
30L(25L) |
600 |
620 |
rotary blowerinstallation dimensions