Air conditioning unit electrode humidifier

NegotiableUpdate on 02/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Air conditioning unit electrode humidifier product series: ASDJ product application: air conditioning matching humidification, clean room humidification, fresh air system humidification product description: air conditioning unit electricity .....
Product Details

Air conditioning unit electrode humidifier

Working principle

Pure tap water enters the humidification tank through the inlet valve, and the water level gradually rises and comes into contact with the electric level. The current forms a circuit through the trace salt in the water, heating and boiling the water. The longer the water level rises, the greater the current flowing through the electric level. When the set current is reached, the inlet valve closes, and steam begins to be generated. As the steam is generated, the water level continues to decrease. When the humidification current is less than 80% of the humidification current, the inlet valve opens again to enter the water and clean the humidification tank. This cycle of work stops when the humidity value is reached.

control form

1. Intelligent control system

1) Control system: Easy to operate, can adjust humidification parameters arbitrarily. There are two types of control modes: switch quantity and proportional adjustment.

2) Proportional adjustment control board: The interface signal is 0~10V or 4-20mA, with a humidification efficiency of 99%, and can control the humidification amount within the range of 20~99% RH. Adjust the humidification ratio in a timely manner according to the different conductivity of water and changes in indoor humidity, control the humidification amount, and keep the humidity constant within the set humidity rangeAir conditioning unit electrode humidifierEquipped with automatic cleaning function, it can automatically adjust the drainage cycle inside the humidification tank according to changes in the soluble mineral content of the water, extending the service life of the humidification tank.

Composition structure

180=1632=0689.png

Steam spray bar

.png

Performance characteristics

Air conditioning unit electrode humidifierStable performance, reliable quality, low noise, and low failure rate.

1. Humidification range: 1kg~120kg;

2. Fast humidification speed: can meet various humidification requirements;

3. Clean humidification: sterile, non-toxic, and free of scale.

Technical Parameter

model

Steam quantitykg/h

powerKW

voltageV/ Hz

Specification and size(mm)LWH

ASDJ-3

3

2.25

380/50

465*215*485

ASDJ-6

6

4.5

380/50

465*215*485

ASDJ-9

9

6.75

380/50

550*270*625

ASDJ-12

12

9

380/50

550*270*625

ASDJ-15

15

11.25

380/50

550*270*625

ASDJ-21

21

15.75

380/50

550*270*625

ASDJ-24

24

18

380/50

550*270*625

ASDJ-30

30

22.5

380/50

550*270*625

ASDJ-36

36

27

380/50

840*270*625

ASDJ-42

42

31.5

380/50

840*270*625

ASDJ-48

48

36

380/50

840*270*625

ASDJ-60

60

45

380/50

840*270*625

ASDJ-75

75

56.25

380/50

1070*270*625

ASDJ-90

90

67.5

380/50

1070*270*625

ASDJ-120

120

90

380/50

1070*270*625

installation

Installation of air conditioning unit and indoor unit

1567001778381722.png

precautions

Choose installationAir conditioning unit electrode humidifierWhen positioning, be sure to pay attention to the following points:

1. Environmental temperature 5-40 ℃

2. Relative humidity below 80% RH

3. The installation location should not exceed an altitude of 2000M

4. Inlet pressure: 0.1~0.5Mpa,

5. Steam distribution pipe andAir conditioning unit electrode humidifierWhen connected, it should be used as much as possible Short length steam outlet hose

6. The hose should avoid sagging and knotting, and should have a slope of 5-10 °

7. Humidifiers must be installed vertically in order to function properly.

Cleaning and maintenance of steam drum

When the humidification capacity of the electrode humidifier does not reach the predetermined humidification capacity, if other components are working normally, it means that the steam drum needs to be cleaned.

Here are the cleaning steps and precautions:

1. Remove the shell, remove the connectors, and take off the upper part of the steam drum.

2. Remove all scale and impurities from the steam drum.

3. Tap the heating electrode to remove the scale on the electrode, allowing a small portion to remain.

4. Check the upper water level detector of the steam drum and rinse to remove any impurities attached to it.

5. Rinse the filter in the steam drum.

6. After cleaning, simply install it and check if it is functioning properly.