Welcome Customer !

Membership

Help

Guangzhou Quanfeng Environmental Protection Equipment Co., Ltd
Custom manufacturer

Main Products:

hbzhan>Products

Guangzhou Quanfeng Environmental Protection Equipment Co., Ltd

  • E-mail

    1095969861@qq.com

  • Phone

    1392422246313318771005

  • Address

    3rd Floor, Building 1, Zhanqing Industrial Park, Haiyong Road, Panyu District, Guangzhou City

Contact Now

Ammonia nitrogen concentration meter ION-7110

NegotiableUpdate on 02/02
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Ion selective sensors directly installed in sewage treatment plants
Product Details

application area

Ion selective sensors directly installed in sewage treatment plants

Measurement is conducted in a sludge tank without the need for any sample pretreatment or sampling

Product transmission. The entire measurement system includes sensors and transmitters:

The sensor contains electrodes, and the transmitter comes with a display and operation unit.

Sensors are used to monitor ammonia nitrogen concentration: sludge tank, primary sedimentation tank outlet

Instrument features

◆ No need for sample pretreatment, directly measure ammonia nitrogen

Potassium ion measurement is optional and can also compensate for high concentration interference

◆ pH measurement and compensation, no need for reagents, low cost of use

◆ Range: 0.1-1000 mg/l NH 4-N

◆ Directly installed at the edge of the pool, without the need for a liquid collector or sample transfer pump

Compressed air cleaning is optional, with low maintenance costs

Replacing the laminated cap every 6 months effectively extends the service life of the electrode

Equipped with RS-485 standard MODBUS communication protocol, it can directly communicate with digital devices

System connection (MB-300-ION-2RS serial only)

Two sets of programmable outputs (MB-300-ION-2 serial only)

Technical Parameter

The input measurement variable depends on the sensor type and measurement range

Ammonia nitrogen: NH4-N, NH4+[mg/l] Ammonia nitrogen: 0.1~1000 mg/l

◆ Potassium ion: K+[mg/l] Potassium ion: 1-1000 mg/l (optional)

◆ pH value and temperature

performance parameter

Response time t90: Ammonia nitrogen:<2 minutes

Potassium ion:<2 minutes

Maximum measurement error (± 5% of the measured value) ± (0.2 mg/l)

± 3% of repeatability display value

Correction mode: two-point or three-point correction, offset value correction (thirteen sections available for selection)

Input impedance>1012 Ω

Relay output with two sets of ON/OFF contact outputs, high and low points, and hysteresis can be set by any program, 240VAC/0.5A

◆ Analog output 1 or 2 channels of 4-20mA analog signal output, users can set the corresponding output value, load 500 Ω

environmental condition

◆ Environmental temperature range -20 .. 50 °C (-4 ... 120 °F)

◆ Storage temperature 2 .. 40 °C (36 ... 100 °F)

◆ Protection level IP 65

Both electromagnetic compatibility (EMC) interference emission and anti-interference emission comply with

EN 61326 and NAMUR NE21 standards

Process conditions

Process temperature range 2 .. 40 °C (36 ... 100 °F)

Maximum allowable overpressure value for process pressure: 400 mbar (160 inH2O)

The pH value of the medium

Ammonia nitrogen: pH 5~8.3 (without pH compensation) pH 5~10 (with pH compensation)

Potassium ion: pH 2~12