Aquaculture water quality monitoring equipment requires a high-precision multi parameter monitoring system to ensure water quality stability. In addition to conventional parameters, special indicators such as residual chlorine need to be monitored. Monitoring sensors are installed at key nodes such as the inlet of circulating water and the outlet of biological filters to track the water purification effect in real time. The monitoring system has increased the utilization rate of water bodies to over 90% while reducing water resource consumption by 30%. Net cage aquaculture is located in an open water environment and is greatly affected by natural factors. Monitoring equipment needs to have anti wind and anti biological attachment characteristics. It is usually installed and fixed around the net cage using anchoring, with a focus on monitoring water flow velocity, dissolved oxygen, and water temperature. For example,
Aquaculture water quality monitoring equipmentFor the requirement of water quality stability, a high-precision multi parameter monitoring system needs to be configured to monitor special indicators such as residual chlorine in addition to conventional parameters. Monitoring sensors are installed at key nodes such as the inlet of circulating water and the outlet of biological filters to track the water purification effect in real time. The monitoring system has increased the utilization rate of water bodies to over 90% while reducing water resource consumption by 30%. Net cage aquaculture is located in an open water environment and is greatly affected by natural factors. Monitoring equipment needs to have anti wind and anti biological attachment characteristics. It is usually installed and fixed around the net cage using anchoring, with a focus on monitoring water flow velocity, dissolved oxygen, and water temperature. For example, in the large yellow croaker cage aquaculture area along the coast of Fujian, the monitoring system combines meteorological data to achieve wind and wave warning, and transfers the cages to sheltered areas in advance, effectively reducing aquaculture losses during typhoon seasons.

1、 Product Introduction
Aquaculture water quality monitoring equipmentIt is a device that can monitor water temperature online ph、 Instruments for ammonia nitrogen, residual chlorine, dissolved oxygen, conductivity, and turbidity can quickly and accurately record key parameters in water bodies. At the same time, the instrument supports the expansion of water quality multi parameter sensors, which can be combined and configured according to different needs and applications, record and store historical monitoring data and alarm history records, and support the export of historical data. The RS485 interface supports the MODBUS-RTU communication protocol, making it convenient for users to communicate freely. It can connect and transmit data with devices such as PLC, DCS, configuration software, DTU, etc.
2、 Application Fields
1. Aquaculture monitoring: used to monitor aquaculture water quality such as ammonia nitrogen PH、 Water temperature and other parameters are used to optimize the breeding environment, improve the production speed and product quality of aquatic products.
2. Groundwater monitoring: used to monitor parameters such as pH value, conductivity, temperature, etc. of groundwater, in order to timely detect and solve water quality problems.
3. River and lake monitoring: used to monitor the water quality of rivers and lakes, such as dissolved oxygen, turbidity, ammonia nitrogen and other parameters, in order to take timely pollution control measures.
4. Ocean monitoring: used to monitor the water quality of the ocean, such as salinity, dissolved oxygen, temperature and other parameters, in order to timely detect and control marine pollution.
5. Wastewater treatment: used to monitor the water quality parameters of wastewater, such as pH value COD、 Ammonia nitrogen and other substances are used to control and regulate the sewage treatment process.
6. Industrial production: used to monitor the water quality status in the industrial production process, such as pH, conductivity, dissolved oxygen and other parameters, in order to adjust the process in a timely manner and ensure product quality.
7. Waterworks: used to monitor the pH value, dissolved oxygen, turbidity and other parameters of tap water, ensuring the safety and hygiene of tap water.
8. Scientific research: used for water quality monitoring in the field of scientific research, such as eutrophication of lakes, climate change, and other studies.
3、 Product Features
1. High reliability: suitable for long-term work in outdoor environments, with stable measurement and strong anti-interference ability.
2. Flexible and portable: Each probe can be freely combined and replaced independently, plug and play.
3. Scalability: Multiple sensors can be freely combined.
4. Multiple applications: rapid on-site measurement, emergency monitoring, or long-term online monitoring of groundwater, river water, lake water sources, and urban pipeline water.
5. Resilient shell: ABS+PC material, corrosion-resistant, capable of long-term continuous normal operation.
6. Compact structure: can be installed in smaller sizes.
7. Communication connection: RS485 expansion interface, isolated master/slave interface for independent communication.
4、 Technical parameters of multi parameter water quality analyzer
| display output |
4.3-inch touch screen with strong LED backlight, operable under direct sunlight |
| power supply |
DC power supply: DC12V |
| power consumption |
The power consumption of the instrument is about 12V/1W |
| Sound output |
buzzer |
| communication protocol |
Standard RS485 Modbus RTU protocol and device master/slave transmission channel support |
| Main materials |
ABS+PC material |
| Storage temperature |
-20 to 70 ℃ |
| Operating temperature |
-10 to 50 ℃ |
| Protection level |
IP65 |
| size |
175mm * 140mm * 49mm (length x width x height) |
| weight |
About 0.5KG |
5、 Sensor parameters
| model |
name |
measurement range |
principle |
measurement accuracy |
resolution |
Is it standard |
remark |
| S1S |
cod |
0~1000mg/ L |
UV254 absorption method |
±5%, ±0.3℃ |
0.1mg/L |
|
COD turbidity integrated; Self cleaning with brush and temperature compensation |
| turbidity |
0~400NTU |
scattered light method |
± 1%, ±0.3℃ |
0.1NTU |
|
| S2 |
Water hardness |
0~1000.0mg/L |
Contact electrode method |
± 10% of the reading; ±0.3℃ |
0.1mg/L |
|
|
| S3 |
pH |
0~14(ph) |
Electrochemistry (salt bridge) |
± 0.1PH; ±0.1℃ |
0.01 |
|
Warm compensation |
| S4 |
residual chlorine |
0~5.00 mg/L |
Ion selective electrode method |
± 5% of the reading; ±0.3℃ |
0.01mg/L |
√ |
Integrated residual chlorine pH; The best accuracy is achieved when the flow rate is between 0.42m/s and 0.85m/s; Warm compensation |
| pH |
0~14(ph) |
Electrochemistry (salt bridge) |
± 0.1PH; ±0.1℃ |
0.01 |
√ |
| S5 |
ammonia nitrogen |
0~1000mg/l |
Ion selective electrode method |
10% of the reading, ± 0.5 ℃ |
0.01mg |
√ |
Ammonia nitrogen pH integrated; Warm compensation |
| pH |
0~14(ph) |
Electrochemistry (salt bridge) |
± 0.1PH; ±0.1℃ |
0.01 |
|
| S6 |
ORP |
-1500mv~1500mv |
Electrochemistry (salt bridge) |
± 6mv |
1mV |
|
|
| S7 |
conductivity |
0~10000uS/cm |
Contact electrode method |
± 1.5%; ±0.1 °C |
1uS/cm |
√ |
Warm compensation |
| S7H |
High range conductivity |
0~30000μS/cm |
Contact electrode method |
± 1.5%; ±0.1 °C |
1uS/cm |
|
High range conductivity TDS salinity integrated sensor; Warm compensation |
| TDS |
0-10000ppm |
Contact electrode method |
± 1.5%; ±0.1 °C |
1ppm |
|
| salinity |
0-10000ppm |
Contact electrode method |
± 1.5%; ±0.1 °C |
1ppm |
|
| S8 |
dissolved oxygen |
0~20mg/L |
Fluorescence lifetime method |
±2%, ±0.3℃ |
0.01mg/L |
√ |
Warm compensation |
| S9 |
turbidity |
0~1000NTU |
scattered light method |
±1% , ±0.3℃ |
0.1NTU |
√ |
Warm compensation |
| S9S |
Self cleaning turbidity |
0~1000NTU |
scattered light method |
±1% , ±0.3℃ |
0.1NTU |
|
Self cleaning with brush; Warm compensation |
| S10 |
suspended solids |
0~2000mg/L |
scattered light method |
± 5% (depending on sludge homogeneity) |
0.1mg/L |
|
|
| S11S |
sludge concentration |
0~20.000g/L |
scattered light method |
± 5% (depending on sludge homogeneity) |
0.001g/L |
|
Self cleaning with brush |
| S14 |
chloride ion |
0-3500.0mg/L |
Ion selective electrode method |
±5%; ±0.3℃ |
0.1mg/L |
|
|
| S15S |
chlorophyll |
0~400ug/L |
fluorescence method |
R²>0.999 |
0.01ug/L |
|
Self cleaning with brush; Warm compensation |
| S16S |
blue-green algae |
0~200.0Kcells/mL |
fluorescence method |
R²>0.999 |
0.1Kcells/mL |
|
Self cleaning with brush |
| S17S |
水中油 |
0~60ppm |
fluorescence method |
0.1ppm |
0.01ppm |
|
Self cleaning with brush |
| S20 |
transparency |
50~1000mm |
scattered light method |
± 5% (depending on sludge homogeneity) |
1mm |
|
Warm compensation |
| S21 |
water temperature |
−20℃~85℃ |
High precision digital sensor |
±0.1℃ |
0.1℃ |
|
|