Automatic chlorine dioxide dosing device for water plantPerformance Characteristics
Efficient sterilization ability: Chlorine dioxide, as a strong oxidant, can quickly kill bacteria, viruses, algae and other microorganisms in water, with good disinfection effect, especially suitable for scenarios with strict water quality requirements.
Easy operation: The device has a simple structure and supports automated operation. Users only need to set the dosage to achieve continuous disinfection, reducing the need for manual intervention.
Safety and reliability: equipped with low liquid level automatic shutdown function to prevent damage to the metering pump due to idling; The medicine storage box is made of corrosion-resistant and strong acid resistant materials to extend the service life of the equipment.
Broad spectrum applicability: Compatible with various disinfectants such as chlorine tablets, chlorine cakes, bleach, etc., and can flexibly adjust the type of medication according to changes in water quality.
Environmentally friendly and pollution-free: The disinfection process does not produce carcinogenic halides (such as trihalomethanes), is environmentally friendly, and does not lower the pH value of water.
Automatic chlorine dioxide dosing device for water plantPrecautions for use
Raw Material Management
Agent A (chlorine dioxide precursor) and Agent B (activator) should be stored separately to avoid mixing; The raw material should be refined industrial salt (≥ 99.1%) to prevent impurities from blocking the equipment.
Operating Specifications
When preparing the medicine, it is strictly prohibited to pour water into the powder. The powder should be slowly added to the water and stirred to dissolve; The activation time should be controlled within 60-90 minutes.
Check the liquid level before equipment operation to prevent the metering pump from running without load; Inlet pressure ≥ 0.2MPa, outlet pressure ≤ 0.3MPa.
safety protection
Operators are required to wear protective gloves, goggles, and gas masks to prevent chemical splashing or gas inhalation.
The equipment room needs good ventilation to avoid the accumulation of chlorine dioxide gas; Immediately activate the exhaust system in case of leakage and neutralize the residue with alkaline solution.
maintenance
Clean the reaction kettle monthly, inspect the electrolytic membrane and electrodes quarterly, and replace them promptly if any damage is found.
Equipment insulation should be done well in winter to prevent liquids from freezing and cracking the equipment.