Welcome Customer !

Membership

Help

Jiangsu Weichuang Environmental Protection Technology Co., Ltd
Custom manufacturer

Main Products:

hbzhan>Products
Product Categories

Jiangsu Weichuang Environmental Protection Technology Co., Ltd

  • E-mail

    vetra0510@163.com

  • Phone

    13812227136

  • Address

    Gaocheng Village, Gaocheng Town, Yixing City, Jiangsu Province

Contact Now

BIOLAK-Friox

NegotiableUpdate on 02/01
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The micro porous aerator has a small diameter of aeration bubbles, a large gas-liquid area, uniform bubble diffusion, no pore blockage, and strong corrosion resistance. The aerator is particularly suitable for urban sewage and large factory construction, aerator expansion, and old aeration tank renovation, and the aeration tank can operate intermittently. Aerators can be divided into flat and spherical shapes according to their appearance. The gas supply pipeline of the aerator is also equipped with adjustable pipe supports, which can ensure the installation level of each aerator through adjustment to achieve the best aeration effect. Connection method and installation of aeration pipeline: The aeration device of the aerator consists of aerator, air distribution pipeline, tee, four-way, elbow, regulator, connector, cleaning device, etc. The gas distribution pipeline is arranged in a usual circular pattern, and the aerator is arranged with a density according to the gas supply volume and pool shape. The connection between the aerator and the gas distribution pipeline is made of G3/4 thread connection, and the base is internal thread (fixed on the gas distribution pipeline). The aerator is external thread. When installing, first fix the regulator to the bottom of the pool with expansion bolts according to the required size, and then fix the gas distribution pipeline to the regulator with clamps. To prevent other operations such as welding sparks and damage to the aeration device by heavy objects such as concrete during civil engineering, the aerator must be installed before water discharge after the completion of the civil engineering project. To prevent air leakage in the pipeline and connecting parts, water should be discharged to a depth of about 10cm beyond the bottom of the aerator for leakage testing. If any air leakage is found in the pipeline connecting part, it should be promptly eliminated And then officially put into operation. Specification of aerator product
Product Details

The micro porous aerator has a small diameter of aeration bubbles, a large gas-liquid area, uniform bubble diffusion, no pore blockage, and strong corrosion resistance. The aerator is particularly suitable for urban sewage and large factory construction, aerator expansion, and old aeration tank renovation, and the aeration tank can operate intermittently. Aerators can be divided into flat and spherical shapes according to their appearance. The gas supply pipeline of the aerator is also equipped with adjustable pipe supports, which can ensure the installation level of each aerator through adjustment to achieve the best aeration effect.

Connection method and installation of aeration pipeline:
The aeration device of the aerator consists of an aerator, gas distribution pipeline, tee, four-way, elbow, regulator, connector, cleaning device, etc. The gas distribution pipeline is arranged in a usual circular pattern, and the aerator is arranged with a density according to the gas supply volume and pool shape. The connection between the aerator and the gas distribution pipeline is made of G3/4 thread connection, and the base is internal thread (fixed on the gas distribution pipeline). The aerator is external thread. When installing, first fix the regulator to the bottom of the pool with expansion bolts according to the required size, and then fix the gas distribution pipeline to the regulator with clamps. To prevent other operations such as welding sparks and damage to the aeration device by heavy objects such as concrete during civil engineering, the aerator must be installed before water discharge after the completion of the civil engineering project. To prevent air leakage in the pipeline and connecting parts, water should be discharged to a depth of about 10cm beyond the bottom of the aerator for leakage testing. If any air leakage is found in the pipeline connecting part, it should be promptly eliminated And then officially put into operation.

Specification of aerator product

Product parameters

Related technical parameters

model

BQLY-200Q

Service area: 0.25-0.55m2/piece
Average operating gap of membrane: 80-100 microns
Air flow rate: 1.5-3m3/h per unit
Oxygen utilization rate: (water depth 3.2m) 18.4-27.7%
Oxygenation capacity: 0.112-0.185kgO2/m3h
Oxygenation power efficiency: 4.46-5.19kgO2/kwh

specifications

Φ200mm

Appearance

Crown shaped, inner thread

material

Rubber film+ABS

quality

245g

model

215mm

Service area: 0.25-0.55m2/piece
Average operating gap of membrane: 80-100 microns
Air flow rate: 1.5-3m3/h per unit
Oxygen utilization rate: (water depth 3.2m) 18.4-27.7%
Oxygenation capacity: 0.112-0.185kgO2/m3h
Oxygenation power efficiency: 4.46-5.19kgO2/kwh

model

260mm

Service area: 0.35-0.75m2/piece
Average operating gap of membrane: 80-100 microns
Air flow rate: 1.5-3m3/h per unit
Oxygen utilization rate: (water depth 3.2m) 18.4-27.7%
Oxygenation capacity: 0.112-0.185kgO2/m3h
Oxygenation power efficiency: 4.46-5.19kgO2/kwh