Beijing electrolytic chlorine dioxide generator manufacturer
Beijing electrolytic chlorine dioxide generator manufacturer
Xiangyi Yuansheng is a key recommended brand in the national water conservancy system product bidding catalog, a selected enterprise in the national rural water conservancy engineering material and equipment product information annual report, a contract abiding and trustworthy enterprise in Changsha, and a member of the China ASEAN Business Council. Daily maintenance methods.
Daily maintenance methods.
1. It is necessary to provide sufficient clean water inside the equipment before the initial operation, and it is strictly prohibited to operate the machine empty.
2. The temperature controlled water tank of the equipment should be regularly replenished with water to prevent damage to the heater. The controller is equipped with a protective device. When the water level in the water tank is lower than the set value, the malfunction light on the control cabinet will light up and water should be replenished immediately.
3. If the power water source suddenly stops supplying water, the metering valve should be immediately closed.
4. The metering pump of the chlorine dioxide generator should stop feeding, and the water injector should continue to operate for more than one hour to allow the CLO2 gas in the reactor to be fully exhausted and prevent gas from overflowing from the inlet pipe.
5. When the material is rich in impurities and prone to blockage, attention should be paid to sorting and unblocking.
6. Chlorine dioxide has strong oxidizing properties, and the soft plastic pipes of equipment are prone to aging and poorly sealed, so they should be checked and replaced regularly.
7. Regularly organize the sediment in the reactor. If the liquid level in the reaction level tube exceeds the normal boundary, it indicates that there is too much sediment and it should be immediately flushed. And check the quality of the materials.
8. Hydrochloric acid is a strong acid, and operators should wear protective gloves. The material NaCLO2 should not be stored together with various acidic substances and should be kept away from sources of fire.
Beijing electrolytic chlorine dioxide generator manufacturer
technical specifications
1. The absorber adopts a water injector, which automatically inhales and produces chlorine dioxide. After entering the water injector, the chlorine dioxide is made into disinfectant and added to the water to be treated. The rated output of the metering pump should be 1.25 times the operating output. Intelligent industrial human-machine interface display, 5.7-inch touch screen, with automatic/manual switch, equipment on/off button, and operation fault signal indicator light on the panel.
2. The sodium chlorate original solution tank is a 6-cubic storage tank made of PE material with excellent oxidation resistance. It is equipped with a magnetic flap level gauge, which has the function of outputting high and low level switch signals. Using sodium chlorate and acid as raw materials, mixed in a 1:1 ratio, it has strong production capacity and high yield. The produced mixed gas contains 68% chlorine dioxide (calculated as 86% based on effective chlorine);
3. The reactor is made of a corrosion-resistant new type and equipped with a safety relief valve to effectively prevent equipment damage caused by system failure and misoperation of the metering pump. The reactor adopts a two-stage reaction, and the conversion rate of the main raw material sodium chlorate is not less than 85%. The negative pressure generated by the water jet will keep the pressure of the reactor and buffer at a lower vacuum pressure.
4. The acid solution tank is equipped with a magnetic flap level gauge, which has the function of outputting high and low level switch signals. The generator has good sealing performance under normal working conditions, and the concentration in indoor environment is less than 3.0mg/m3. The control system adopts PLC programmable controller.
5. A 6 cubic meter PE salt storage tank can effectively resist acid corrosion The acid metering pump and sodium chlorate metering pump are both of positive displacement type, with a flow adjustment range of 0 to adjustable. The design of the metering pump is calculated based on 1.25 times the operating output, and the Milton Roy metering pump is selected for high precision and accurate measurement, which can operate for a long time under highly corrosive conditions.