The LR-BBR-PLUS bending beam rheometer is used to test the low-temperature bending creep stiffness of asphalt binders according to current specifications and SHRP methods. Used to evaluate the low-temperature fracture characteristics of asphalt binder. The test results include indicators of low-temperature creep stiffness S (t) and creep stiffness change rate m (t). Cooling the temperature from room temperature to -40 ° C using Peltier technology/compressor; #176; C, Using magnetic stirring, the temperature control accuracy is 0.1 #176; Within C, RS-232/IP/USB communication is used between the computer and BBR to control BBR, and the software can generate test reports.

Product Details

Meet the specifications:

LR-BBR-PLUSBending beam flowmeterASTM D 6648;AASHTO T3143-09JTG E20T 0627-2011.


Product Introduction

LR-BBR-PLUSBending beam flowmeterAccording to current regulations andSHRPMethod: Test the low-temperature bending creep stiffness of asphalt binder. Used to evaluate the low-temperature fracture characteristics of asphalt binder. The test results include low-temperature creep stiffnessS(t)And creep stiffness change ratem(t)Indicators. usePeltiertechnology/The compressor cools the temperature from room temperature to-40°CUsing magnetic stirring, the temperature control accuracy is within0.1°CInside, computers andBBRBetween adoptionRS-232/IP/USBCommunication, realizing theBBRControl, software can generate test reports.


Product Features:

  • Precision calibration kit (calibration weights, calibration beams, calibration)LVDTdedicated,Digital thermometer);

  • In most laboratory environments, the cooling temperature reaches-40℃;

  • Adopting a durable and corrosion-resistant structure;

  • Touch screen or computer control, data acquisition and analysis;

  • Digital displayPIDTemperature control;

  • Two independent platinum resistorsNLDCapable of accurately controlling temperature;

  • Built in displacement sensorLVDTThe force sensor with temperature compensation can make the results more accurate;

  • Using air bearings to ensure stable and accurate loading;

  • ASTM/AASHTO standard test molds.


Technical Specifications:

  • Loading method: Air bearing loading;

  • Load range:0-5000mN

  • Load accuracy: 1mN

  • Bending creep stiffness modulus:20-1000Mpa

  • Displacement range:0-10mm

  • Displacement accuracy:0.001mm

  • Temperature range:-40℃~room temperature;

  • Temperature accuracy:0.1℃;

  • Preloading force:35mN(±10mN);

  • Actual loading force:980mN(±50mN);

  • Power supply220V50Hz.