Research and Design
1. Adopting German technology, using ADC12 aluminum for one-time die casting and high-precision CNC machining;
2. The insulation level of the motor is TEFC IP55 standard, with an insulation level of H, and the body can withstand temperatures up to 180 degrees;
3. The motor meets the EFF2 standard, which is particularly electric and durable;
4. The new design of the front bearing ensures that our product is highly dynamic and stable during operation;
5. The impeller is directly connected to the motor shaft, requiring no other accessories during rotation, no friction during operation, and no internal lubrication. Therefore, the output air is oil-free, pure, and environmentally friendly;
6. High performance sealing rings effectively prevent foreign objects from entering the body, effectively improving the product's service life;
7. After testing, the fan can operate smoothly and quietly for a long time, and the company provides multiple power and size options for selection;
8. The products undergo strict testing and verification before leaving the factory to ensure the efficiency of customer use.
Boiler combustion supporting, high-temperature resistant, medium pressure blowerJob characteristics
1. All are aluminum shells, reliable in operation, sturdy and durable.
2. Running with little or no oil can improve energy efficiency by producing clean air output.
3. Maintenance free use, its consumable parts are only two bearings, which can be used without maintenance within the warranty period.
4. Compared to centrifugal fans, its pressure is much higher, often more than ten times that of centrifugal fans.
5. Mechanical wear is very minimal because there are no other mechanical contact parts besides bearings, so the service life is long.
6. Low noise and motor-driven ground noise reduction equipment, achieving low vibration.
7. Small in size, easy to install and use on various mechanical equipment.


Boiler combustion supporting, high-temperature resistant, medium pressure blowerThe maintenance is as follows:
1、 Inspection of lubrication system (it is strictly prohibited to operate the rotary fan in a state of oil shortage)
a、 Firstly, check if the oil level in the fuel tank is below the low level. If there is insufficient oil, please add more oil (the oil grade is ISO standard 46 # turbine oil, and the oil grade can be appropriately reduced in low-temperature and cold regions).
b、 Regularly check whether the engine oil has deteriorated due to the presence of water or other contaminants. If it has deteriorated, please replace the engine oil in a timely manner.
c、 Regularly check whether the oil dripping condition of the drip nozzle is normal. If the drip nozzle is dirty, remove the adjustment screw and clean it.
d、 Daily cleaning of oil filters.
2、 Inspection of air filter
Daily check if the air filter is dirty. If it is dirty, remove the air filter, unscrew the butterfly nut, remove the cover, and clean the filter sponge (be careful not to drop dirt into the fan body when removing the filter).
3、 Inspection of Triangle Belt
After running for a period of time, the triangular belt of the rotary fan will elongate. At this time, the fixing bolts of the motor should be loosened, the motor should be moved, and the triangular belt should be tightened to the appropriate position before tightening the fixing bolts of the motor. It should be noted that the end faces of the motor pulley and the fan pulley should be on the same plane. At the same time, check whether the top screws of the two pulleys are loose. If they are loose, please tighten them.
4、 Check the flexibility of the safety valve on a daily basis. If it is not flexible, please clean and debug it to ensure reliable opening and closing.
5、 Check for any oil or gas leaks on a daily basis and repair them. If they cannot be repaired, please notify the manufacturer immediately.
6、 Daily cleaning of the fan room, maintaining cleanliness and good ventilation.
7、 Regularly check the operation status of the fan and motor. If abnormal noise or temperature is found, stop the machine for maintenance in a timely manner, identify the cause of the malfunction, and provide solutions.