NegotiableUpdate on 03/13
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Brand: Quanda Pump Valve Address: Oubei, Yongjia, Wenzhou, Zhejiang Model: CDLF Stainless Steel Multi stage Centrifugal Pump Manufacturer Direct Sales Power: 0.37KW~110KW Flow: 1~200m3/h Head: 11.5~225m
Product Details

CDLF stainless steel multi-stage centrifugal pumpIt is manufactured using advanced international technology, and its biggest advantage is the use of advanced hydraulic model design, high efficiency, and high energy saving. This itemcentrifugal pumpThe impeller, pump casing and its main accessories inside the pump are made of stainless steel stamping, with a particularly smooth flow channel. The bearing and shaft are made of hard alloy, which has a super long service life and avoids secondary pollution. The shaft seal adopts wear-resistant mechanical seal, with no leakage. The motor adopts an aluminum shell, imported bearings, and insulation grade F. The pump runs smoothly, with low noise, reliable overall quality, beautiful appearance, small size, light weight, and easy transportation and installation. It is an ideal green, environmentally friendly, and energy-saving water pump.

CDLF stainless steel multi-stage centrifugal pumpTransport medium

1. A non flammable and explosive medium that is thin, clean, and free of solid particles or fibers.
2. Such as mineral water, softened water, pure water, clear oil, and other light chemical media.
3. The main material of the pump is stainless steel, which can be used to pump mildly corrosive media.
CDLF stainless steel stamping multi-stage centrifugal pumpMain application industries
Water supply: filtration and transportation of water plants, water supply to different zones of water plants, main pipeline pressurization, and pressurization of high-rise buildings.
Industrial pressurization: process water system, cleaning system, high-pressure flushing system, fire protection system.
Industrial liquid transportation: cooling and air conditioning systems, boiler feedwater and condensing systems, machine tool matching, and transportation of acidic and alkaline media.
Water treatment: ultrafiltration system, reverse osmosis system, distillation system, separator, and water treatment system for swimming pools.
Irrigation: farmland irrigation, sprinkler irrigation, drip irrigation.
CDLF stainless steel stamping multi-stage centrifugal pumpWhat are the advantages?
The CDLF vertical stainless steel multi-stage pump adopts excellent hydraulic models and advanced manufacturing processes, greatly improving the performance and service life of the pump.
2. Due to the use of mechanical seals made of hard alloy and fluororubber, the reliability of pump operation and the temperature of the conveying medium can be improved.
The overcurrent part of the pump is made of stainless steel plate stamped and welded, making the pump suitable for mildly corrosive media.
4. The overall structure is compact, small in size, light in weight, low in noise, significant in energy-saving effect, and easy to maintain.
5. The inlet and outlet of the pump are located on the same horizontal line as the pump seat and can be directly used in the pipeline.
6. Using standard motors, users can easily equip motors according to their needs.
7. Intelligent protectors can be equipped according to user needs to effectively protect pumps from dry running, phase loss, overload, etc.
CDLF stainless steel stamping multi-stage centrifugal pumpModel Description
http://www.quandabf.cn/duojibeng/pr_53.html
CDLF stainless steel stamping multi-stage centrifugal pumpinternal structure

http://www.quandabf.cn/duojibeng/pr_53.html

Serial Number

Component Name

Serial Number

Component Name

1

electrical machinery

5

Intermediate cavity

2

rack

6

base

3

axle

7

pump body

4

impeller

8

mechanical seal

CDLF stainless steel stamping multi-stage centrifugal pumpPerformance Curve
CDLF不锈钢冲压多级离心泵
What are the requirements for CDLF stainless steel stamping multi-stage centrifugal pump?
1. The CDLF vertical stainless steel multi-stage pump should be installed vertically on the ground, and sufficient cold air should be ensured to enter the motor cooling fan during installation. The bottom arrow of the pump indicates the direction of flow through the pump.
To minimize the possible noise generated by the pump, it is best to install anti vibration fasteners on both sides of the pump and between the foundation and the pump body. The docking flange, gasket, bolt, and PJE joint are provided as accessories and must be ordered separately. If necessary, when cleaning, repairing, or replacing the pump, isolation valves should be installed on both sides of the pump to prevent system drainage. The installation pipeline of multi-stage centrifugal pumps should avoid air blockage, especially on the suction side of the pump. The pipe should be installed in such a way that any stretching caused by temperature changes will not affect the pump. If the pump is installed on a long pipe, it should be properly supported both in front and behind as shown.
If there is a risk of blockage by stones, leaves, small supports, etc. in multi-stage centrifugal pumps, measures should be taken to prevent such incidents from happening. Install a filter screen on the straw area.
4. In some installation situations, if the drainage pipe is already installed horizontally or tilted downwards by the pump, the water inside the pump will or will inevitably flow out at intervals, and the pump should be protected from causing the impeller to idle. Installing a faulty pipe with a vacuum valve near the pump can avoid this situation. The highest point of the ring pipe should be at least level with the connecting plate of the pump's motor. This way, the drainage pipe can independently drain water from the pump, and vice versa.
When the drain valve is closed, the pump is prohibited from running because it can cause an increase in temperature/vapor formation inside the pump, leading to pump damage. If there is any danger to the operation of the pump when the drainage room is closed, connect a bypass or drain pipe to the outlet to ensure that the minimum amount of liquid flows through the pump. A drain pipe, for example, can be connected to a water tank.
6. The minimum quantity of QDL and QDLF light-duty multi-stage pumps.
CDLF stainless steel stamping multi-stage centrifugal pumpcontrol requirements
1. Before opening the junction box cover and removing the components of the CDLF vertical stainless steel multi-stage pump, the power must be turned off. Electrical connections must be made by qualified electricians in accordance with local regulations. The motor junction box must be correctly connected to the power switch with wires. The operating voltage and frequency are marked on the nameplate. Please note that the power source used should be suitable for the electric motor. The three-phase motor must be connected to a starter with a protective function.
2. The junction box of the lightweight multi-stage pump can be rotated 90 ° and stopped at four positions in sequence. When needed, use a screwdriver to remove the coupling guard plate, but do not remove the coupling. Unscrew the bolts that secure the motor to the pump. Rotate the motor to the desired position. Tighten the bolts again. Reinstall the coupling guard plate so that it is vertically aligned in the recess of the pump head. Electrical connections should be made according to the wiring diagram inside the junction box cover.
Note: Do not start the light multi-stage pump until it is filled with liquid.
CDLF stainless steel stamping multi-stage centrifugal pumpTypical applications
An example of a typical high-pressure flushing system diagram. Recommend this installation method as shown in the figure for situations where the "minimum flow" through the pump cannot be guaranteed.
1. The liquid flow switch of the CDLF vertical stainless steel multi-stage pump will provide protection for the pump, preventing it from being damaged due to high heat generated during operation when the liquid flow is too small.
2. The filter screen of a lightweight multi-stage pump is installed to protect the liquid flow switch in devices used for transporting slightly polluted water.
Note: The above measures are not necessary in devices with stable liquid flow conditions and the ability to ensure minimum flow rate. In devices with water hammer hazards, a check valve must be installed at the outlet of the pump. Do not use quick closing valves, such as quick closing spray guns, as they can cause water hammer. Affects the connection between the motor and the pump shaft, and in severe cases can cause the pump shaft to break.
CDLF stainless steel stamping multi-stage centrifugal pumpCorrect startup method
When the liquid level of the CDLF vertical stainless steel multi-stage pump is higher than that of the closed or open system at the pump inlet:
1. Close the drainage isolation valve and loosen the exhaust screw on the pump head.
2. Please pay attention to the direction of the exhaust port and ensure that the water flowing out does not cause harm to people or damage to the motor or other components. In hot water systems, special attention should be paid to the risk of burns caused by hot water.
3. Slowly open the isolation valve on the suction pipe until a steady stream of liquid flows out of the exhaust valve.
4. When starting the light-duty multi-stage pump, tighten the exhaust screw and fully open the isolation valve.
CDLF stainless steel stamping multi-stage centrifugal pumpLiquid level below pump inlet open system:
1. The suction pipe and pump must be filled with liquid and vented before starting the pump.
2 QDL2、4(QDLF2、4、8、16)
3. Close the drainage isolation valve. Rotate the bypass valve slightly towards the stop as shown in Figure 7.
4. Remove the infusion plug and inject liquid from the infusion port until the suction pipe and pump are completely filled with liquid, then tighten the bypass valve again.
5. When starting the light-duty multi-stage pump, replace the filling plug and tighten it firmly.
CDLF stainless steel stamping multi-stage centrifugal pumpCheck the direction of rotation during startup:
1. Do not start the light multi-stage pump to check the direction of rotation until it is filled with liquid.
2. When checking the direction of motor operation, the coupling should not be disassembled for inspection. Because when the coupling is removed, the position of the shaft needs to be adjusted. The correct direction of rotation is indicated by the arrow on the pump head or on the motor fan cover. From the perspective of the fan, the lightweight multi-stage pump should rotate counterclockwise.
CDLF stainless steel stamping multi-stage centrifugal pumpStart up:
1. Before starting the light-duty multi-stage pump, the pump suction side isolation valve should be fully opened, while the discharge side isolation valve should be almost closed.
2. When starting a lightweight multi-stage pump, loosen the exhaust screw on the pump head to allow the pump to exhaust until a steady flow of liquid flows out from the exhaust hole, and then tighten the exhaust screw.
Attention: The direction of the exhaust hole should be ensured that the liquid flowing out will not cause harm to people or damage to the motor or other components. In hot water systems, special attention should be paid to the risk of burns caused by hot water. When the pipeline system is filled with liquid, slowly open the isolation valve until it is fully opened. When pumping liquids containing air, it is best to regularly exhaust the pump. To exhaust the pump, loosen the exhaust screw on the pump head during operation.
CDLF stainless steel stamping multi-stage centrifugal pumpHow to maintain it
Before starting the vertical multi-stage pump, it is necessary to verify that there is no power supply to the pump and that the pump cannot suddenly start.
The bearings and shaft seals of lightweight multi-stage pumps do not require maintenance. If the pump is not in use for a long time and needs to be drained, one of the coupling guard plates can be removed, and a few drops of silicone oil can be injected into the shaft between the pump head and the coupling. This can prevent the shaft sealing surface from sticking.
3. When installing the coupling guard, be sure that they are vertically aligned in the recess of the pump head.
CDLF stainless steel stamping multi-stage centrifugal pumpElectric motor bearings:
4. Motors without lubrication nozzles do not require maintenance. Electric motors equipped with lubrication nozzles should be lubricated with high-temperature lithium based grease.
5. If the light-duty multi-stage pump is temporarily suspended, it is recommended to clean and lubricate the pump and motor once it is no longer in use.
During the frost period, if the pump is not in use, the water should be drained to prevent damage and cracking. Loosen the exhaust screw on the pump head and remove the drain plug on the base to drain the pump. After the water is drained, the removed components should be reinstalled or properly stored.
7. The starting and stopping frequency of CDLF vertical stainless steel multi-stage pump shall not exceed 100 times per hour for electric motors with a power of less than 4KW. The starting frequency of other motors shall not exceed 20 times per hour.
CDLF stainless steel stamping multi-stage centrifugal pumpSelection parameters


Model of multi-stage centrifugal pump

Head (m)

Flow rate (m3/h)

Motor power (KW)

Speed (r/min)

CDL1-2 multi-stage centrifugal pump

11.5

1

0.37

2900

CDL1-3 multi-stage centrifugal pump

17

1

0.37

2900

CDL1-4 multi-stage centrifugal pump

22.5

1

0.37

2900

CDL1-5 multi-stage centrifugal pump

28

1

0.37

2900

CDL1-6 multi-stage centrifugal pump

33.5

1

0.37

2900

CDL1-7 multi-stage centrifugal pump

39

1

0.37

2900

CDL1-8 multi-stage centrifugal pump

45

1

0.55

2900

CDL1-9 multi-stage centrifugal pump

51

1

0.55

2900

CDL1-10 multi-stage centrifugal pump

57

1

0.55

2900

CDL1-17 multi-stage centrifugal pump

95

1

1.1

2900

CDL1-19 multi-stage centrifugal pump

106

1

1.1

2900

CDL1-21 multi-stage centrifugal pump

117

1

1.1

2900

CDL1-23 multi-stage centrifugal pump

128

1

1.1

2900

CDL1-25 multi-stage centrifugal pump

139

1

1.5

2900

CDL1-27 multi-stage centrifugal pump

150

1

1.5

2900

CDL1-30 multi-stage centrifugal pump

166

1

1.5

2900

CDL1-33 multi-stage centrifugal pump

183

1

2.2

2900

CDL1-36 multi-stage centrifugal pump

200

1

2.2

2900

CDL2-2 multi-stage centrifugal pump

15

2

0.37

2900

CDL2-3 multi-stage centrifugal pump

22

2

0.37

2900

CDL2-4 multi-stage centrifugal pump

30

2

0.55

2900

CDL2-5 multi-stage centrifugal pump

37

2

0.55

2900

CDL2-6 multi-stage centrifugal pump

45

2

0.75

2900

CDL2-7 multi-stage centrifugal pump

52

2

0.75

2900

CDL2-9 multi-stage centrifugal pump

67

2

1.1

2900

CDL2-11 multi-stage centrifugal pump

82

2

1.1

2900

CDL2-13 multi-stage centrifugal pump

98

2

1.5

2900

CDL2-15 multi-stage centrifugal pump

112

2

1.5

2900

CDL2-18 multi-stage centrifugal pump

136

2

2.2

2900

CDL2-22 multi-stage centrifugal pump

165

2

2.2

2900

CDL2-26 multi-stage centrifugal pump

198

2

3.0

2900

CDL3-2 multi-stage centrifugal pump

9

3

0.37

2900

CDL3-3 multi-stage centrifugal pump

14

3

0.37

2900

CDL3-4 multi-stage centrifugal pump

19

3

0.37

2900

CDL3-5 multi-stage centrifugal pump

23

3

0.37

2900

CDL3-6 multi-stage centrifugal pump

28

3

0.55

2900

CDL3-7 multi-stage centrifugal pump

32

3

0.55

2900

CDL3-8 multi-stage centrifugal pump

37

3

0.75

2900

CDL3-9 multi-stage centrifugal pump

42

3

0.75

2900

CDL3-10 multi-stage centrifugal pump

47

3

0.75

2900

CDL3-11 multi-stage centrifugal pump

51

3

1.1

2900

CDL3-12 multi-stage centrifugal pump

55

3

1.1

2900

CDL3-13 multi-stage centrifugal pump

60

3

1.1

2900

CDL3-15 multi-stage centrifugal pump

69

3

1.1

2900

CDL3-17 multi-stage centrifugal pump

79

3

1.5

2900

CDL3-19 multi-stage centrifugal pump

88

3

1.5

2900

CDL3-21 multi-stage centrifugal pump

98

3

2.2

2900

CDL3-23 multi-stage centrifugal pump

107

3

2.2

2900

CDL3-25 multi-stage centrifugal pump

116

3

2.2

2900

CDL3-27 multi-stage centrifugal pump

124

3

2.2

2900

CDL3-29 multi-stage centrifugal pump

133

3

2.2

2900

CDL3-31 multi-stage centrifugal pump

142

3

3

2900

CDL3-33 multi-stage centrifugal pump

151

3

3

2900

CDL3-36 multi-stage centrifugal pump

168

3

3

2900

CDL4-2 multi-stage centrifugal pump

15

4

0.37

2900

CDL4-3 multi-stage centrifugal pump

24

4

0.55

2900

CDL4-4 multi-stage centrifugal pump

32

4

0.75

2900

CDL4-5 multi-stage centrifugal pump

40

4

1.1

2900

CDL4-6 multi-stage centrifugal pump

48

4

1.1

2900

CDL4-7 multi-stage centrifugal pump

56

4

1.5

2900

CDL4-8 multi-stage centrifugal pump

64

4

1.5

2900

CDL4-10 multi-stage centrifugal pump

81

4

2.2

2900

CDL4-12 multi-stage centrifugal pump

95

4

2.2

2900

CDL4-14 multi-stage centrifugal pump

112

4

3

2900

CDL4-16 multi-stage centrifugal pump

129

4

3

2900

CDL4-19 multi-stage centrifugal pump

153

4

4

2900

CDL4-22 multi-stage centrifugal pump

178

4

4

2900

CDL8-1 multi-stage centrifugal pump

9

8

0.75

2900

CDL8-2 multi-stage centrifugal pump

18

8

0.75

2900

CDL8-3 multi-stage centrifugal pump

27

8

1.1

2900

CDL8-4 multi-stage centrifugal pump

36

8

1.5

2900

CDL8-5 multi-stage centrifugal pump

45

8

2.2

2900

CDL8-6 multi-stage centrifugal pump

54

8

2.2

2900

CDL8-8 multi-stage centrifugal pump

73

8

3.0

2900

CDL8-10 multi-stage centrifugal pump

92

8

4.0

2900

CDL8-12 multi-stage centrifugal pump

111

8

4.0

2900

CDL8-14 multi-stage centrifugal pump

130

8

5.5

2900

CDL8-16 multi-stage centrifugal pump

148

8

5.5

2900

CDL8-18 multi-stage centrifugal pump

167

8

7.5

2900

CDL8-20 multi-stage centrifugal pump

186

8

7.5

2900

CDL12-2 multi-stage centrifugal pump

20

12

1.5

2900

CDL12-3 multi-stage centrifugal pump

30

12

2.2

2900

CDL12-4 multi-stage centrifugal pump

40

12

3

2900

CDL12-5 multi-stage centrifugal pump

50

12

3

2900

CDL12-6 multi-stage centrifugal pump

60

12

4

2900

CDL12-7 multi-stage centrifugal pump

70

12

5.5

2900

CDL12-8 multi-stage centrifugal pump

80

12

5.5

2900

CDL12-9 multi-stage centrifugal pump

91

12

5.5

2900

CDL12-10 multi-stage centrifugal pump

101

12

7.5

2900

CDL12-12 multi-stage centrifugal pump

121

12

7.5

2900

CDL12-14 multi-stage centrifugal pump

141

12

11

2900

CDL12-16 multi-stage centrifugal pump

162

12

11

2900

CDL12-18 multi-stage centrifugal pump

183

12

11

2900

CDL16-2 multi-stage centrifugal pump

22

16

2.2

2900

CDL16-3 multi-stage centrifugal pump

34

16

3.0

2900

CDL16-4 multi-stage centrifugal pump

46

16

4.0

2900

CDL16-5 multi-stage centrifugal pump

58

16

5.5

2900

CDL16-6 multi-stage centrifugal pump

70

16

5.5

2900

CDL16-7 multi-stage centrifugal pump

82

16

7.5

2900

CDL16-8 multi-stage centrifugal pump

94

16

7.5

2900

CDL16-10 multi-stage centrifugal pump

118

16

11

2900

CDL16-12 multi-stage centrifugal pump

141

16

11

2900

CDL16-14 multi-stage centrifugal pump

166

16

15

2900

CDL16-16 multi-stage centrifugal pump

189

16

15

2900

CDL20-1 multi-stage centrifugal pump

10

20

1.1

2900

CDL20-2 multi-stage centrifugal pump

23

20

2.2

2900

CDL20-3 multi-stage centrifugal pump

35

20

4.0

2900

CDL20-4 multi-stage centrifugal pump

47

20

5.5

2900

CDL20-5 multi-stage centrifugal pump

58

20

5.5

2900

CDL20-6 multi-stage centrifugal pump

70

20

7.5

2900

CDL20-7 multi-stage centrifugal pump

82

20

7.5

2900

CDL20-8 multi-stage centrifugal pump

94

20

11

2900

CDL20-10 multi-stage centrifugal pump

118

20

11

2900

CDL20-12 multi-stage centrifugal pump

142

20

15

2900

CDL20-14 multi-stage centrifugal pump

166

20

15

2900

CDL20-17 multi-stage centrifugal pump

202

20

18.5

2900

CDL32-10-1 multi-stage centrifugal pump

9

32

1.5

2900

CDL32-10 multi-stage centrifugal pump

13

32

2.2

2900

CDL32-20-2 multi-stage centrifugal pump

20

32

3.0

2900

CDL32-20 multi-stage centrifugal pump

27

32

4.0

2900

CDL32-30-2 multi-stage centrifugal pump

33

32

5.5

2900

CDL32-30 multi-stage centrifugal pump

40

32

5.5

2900

CDL32-40-2 multi-stage centrifugal pump

46

32

7.5

2900

CDL32-40 multi-stage centrifugal pump

53

32

7.5

2900

CDL32-50-2 multi-stage centrifugal pump

60

32

11

2900

CDL32-50 multi-stage centrifugal pump

67

32

11

2900

CDL32-60-2 multi-stage centrifugal pump

74

32

11

2900

CDL32-60 multi-stage centrifugal pump

81

32

11

2900

CDL32-70-2 multi-stage centrifugal pump

88

32

15

2900

CDL32-70 multi-stage centrifugal pump

95

32

15

2900

CDL32-80-2 multi-stage centrifugal pump

102

32

15

2900

CDL32-80 multi-stage centrifugal pump

109

32

15

2900

CDL32-90-2 multi-stage centrifugal pump

117,

32

18.5

2900

CDL32-90 multi-stage centrifugal pump

124

32

18.5

2900

CDL32-100-2 multi-stage centrifugal pump

131

32

18.5

2900

CDL32-100 multi-stage centrifugal pump

138

32

18.5

2900

CDL32-110-2 multi-stage centrifugal pump

146

32

22

2900

CDL32-110 multi-stage centrifugal pump

153

32

22

2900

CDL32-120-2 multi-stage centrifugal pump

160

32

22

2900

CDL32-120 multi-stage centrifugal pump

167

32

22

2900

CDL32-130-2 multi-stage centrifugal pump

174

32

30

2900

CDL32-130 multi-stage centrifugal pump

181

32

30

2900

CDL32-140-2 multi-stage centrifugal pump

189

32

30

2900

CDL32-140 multi-stage centrifugal pump

196

32

30

2900

CDL32-150-2 multi-stage centrifugal pump

203

32

30

2900

CDL32-150 multi-stage centrifugal pump

210

32

30

2900

CDL32-160-2 multi-stage centrifugal pump

218

32

30

2900

CDL32-160 multi-stage centrifugal pump

225

32

30

2900

CDL42-10-1 multi-stage centrifugal pump

16

42

3.0

2900

CDL42-10 multi-stage centrifugal pump

20

42

4.0

2900

CDL42-20-2 multi-stage centrifugal pump

32

42

5.5

2900

CDL42-20 multi-stage centrifugal pump

41

42

7.5

2900

CDL42-30-2 multi-stage centrifugal pump

52

42

11

2900

CDL42-30 multi-stage centrifugal pump

61

42

11

2900

CDL42-40-2 multi-stage centrifugal pump

73

42

15

2900

CDL42-40 multi-stage centrifugal pump

81

42

15

2900

CDL42-50-2 multi-stage centrifugal pump

93

42

18.5

2900

CDL42-50 multi-stage centrifugal pump

101

42

18.5

2900

CDL42-60-2 multi-stage centrifugal pump

113

42

22

2900

CDL42-60 multi-stage centrifugal pump

122

42

22

2900

CDL42-70-2 multi-stage centrifugal pump

134

42

30

2900

CDL42-70 multi-stage centrifugal pump

142

42

30

2900

CDL42-80-2 multi-stage centrifugal pump

154

42

30

2900

CDL42-80 multi-stage centrifugal pump

162

42

30

2900

CDL42-90-2 multi-stage centrifugal pump

174

42

30

2900

CDL42-90 multi-stage centrifugal pump

183

42

37

2900

CDL42-100-2 multi-stage centrifugal pump

194

42

37

2900

CDL42-100 multi-stage centrifugal pump

203

42

37

2900

CDL42-110-2 multi-stage centrifugal pump

217

42

45

2900

CDL42-110 multi-stage centrifugal pump

225

42

45

2900

CDL42-120-2 multi-stage centrifugal pump

238

42

45

2900

CDL42-120 multi-stage centrifugal pump

247

42

45

2900

CDL42-130-2 multi-stage centrifugal pump

259

42

45

2900

CDL65-10-1 multi-stage centrifugal pump

13

65

4.0

2900

CDL65-10 multi-stage centrifugal pump

20

65

5.5

2900

CDL65-20-2 multi-stage centrifugal pump

26

65

7.5

2900

CDL65-20-1 multi-stage centrifugal pump

33

65

11

2900

CDL65-20 multi-stage centrifugal pump

40

65

11

2900

CDL65-30-2 multi-stage centrifugal pump

46

65

15

2900

CDL65-30-1 multi-stage centrifugal pump

53

65

15

2900

CDL65-30 multi-stage centrifugal pump

60

65

18.5

2900

CDL65-40-2 multi-stage centrifugal pump

66

65

18.5

2900

CDL65-40-1 multi-stage centrifugal pump

73

65

22

2900

CDL65-40 multi-stage centrifugal pump

80

65

22

2900

CDL65-50-2 multi-stage centrifugal pump

88

65

30

2900

CDL65-50-1 multi-stage centrifugal pump

95

65

30

2900

CDL65-50 multi-stage centrifugal pump

102

65

30

2900

CDL65-60-2 multi-stage centrifugal pump

110

65

30

2900

CDL65-60-1 multi-stage centrifugal pump

117

65

37

2900

CDL65-60 multi-stage centrifugal pump

124

65

37

2900

CDL65-70-2 multi-stage centrifugal pump

132

65

37

2900

CDL65-70-1 multi-stage centrifugal pump

139

65

37

2900

CDL65-70 multi-stage centrifugal pump

146

65

45

2900

CDL65-80-2 multi-stage centrifugal pump

154

65

45

2900

CDL65-80-1 multi-stage centrifugal pump

161

65

45

2900

CDL85-10-1 multi-stage centrifugal pump

14

85

5.5

2900

CDL85-10 multi-stage centrifugal pump

20

85

7.5

2900

CDL85-20-2 multi-stage centrifugal pump

30

85

11

2900

CDL85-20 multi-stage centrifugal pump

41

85

15

2900

CDL85-30-2 multi-stage centrifugal pump

52

85

18.5

2900

CDL85-30 multi-stage centrifugal pump

64

85

22

2900

CDL85-40-2 multi-stage centrifugal pump

75

85

30

2900

CDL85-40 multi-stage centrifugal pump

86

85

30

2900

CDL85-50-2 multi-stage centrifugal pump

98

85

37

2900

CDL85-50 multi-stage centrifugal pump

110

85

37

2900

CDL85-60-2 multi-stage centrifugal pump

122

85

45

2900

CDL85-60 multi-stage centrifugal pump

134

85

45

2900

CDL120-10 multi-stage centrifugal pump

18.5

120

11

2950

CDL120-20-2 multi-stage centrifugal pump

28.5

120

15

2950

CDL120-20-1 multi-stage centrifugal pump

34.5

120

18.5

2950

CDL120-20 multi-stage centrifugal pump

40

120

22

2950

CDL120-30-2 multi-stage centrifugal pump

49

120

30

2950

CDL120-30-1 multi-stage centrifugal pump

55.5

120

30

2950

CDL120-30 multi-stage centrifugal pump

61

120

30

2950

CDL120-40-2 multi-stage centrifugal pump

69

120

37

2950

CDL120-40-1 multi-stage centrifugal pump

76

120

37

2950

CDL120-40 multi-stage centrifugal pump

81

120

45

2950

CDL120-50-2 multi-stage centrifugal pump

90

120

45

2950

CDL120-50-1 multi-stage centrifugal pump

97

120

45

2950

CDL120-50 multi-stage centrifugal pump

101.5

120

55

2950

CDL120-60-2 multi-stage centrifugal pump

110

120

55

2950

CDL120-60-1 multi-stage centrifugal pump

118

120

55

2950

CDL120-60 multi-stage centrifugal pump

123

120

75

2950

CDL120-70-2 multi-stage centrifugal pump

130

120

75

2950

CDL120-70-1 multi-stage centrifugal pump

137.5

120

75

2950

CDL120-70 multi-stage centrifugal pump

145

120

75

2950

CDL150-10-1 multi-stage centrifugal pump

12.5

150

11

2950

CDL150-10 multi-stage centrifugal pump

18.5

150

15

2950

CDL150-20-2 multi-stage centrifugal pump

27.5

150

18.5

2950

CDL150-20-1 multi-stage centrifugal pump

35

150

22

2950

CDL150-20 multi-stage centrifugal pump

40

150

30

2950

CDL150-30-2 multi-stage centrifugal pump

49

150

30

2950

CDL150-30-1 multi-stage centrifugal pump

56

150

37

2950

CDL150-30 multi-stage centrifugal pump

63

150

37

2950

CDL150-40-2 multi-stage centrifugal pump

70.5

150

45

2950

CDL150-40-1 multi-stage centrifugal pump

77

150

45

2950

CDL150-40 multi-stage centrifugal pump

84

150

50

2950

CDL150-50-2 multi-stage centrifugal pump

92

150

55

2950

CDL150-50-1 multi-stage centrifugal pump

99

150

75

2950

CDL150-50 multi-stage centrifugal pump

106.5

150

75

2950

CDL150-60-2 multi-stage centrifugal pump

112

150

75

2950

CDL150-60-1 multi-stage centrifugal pump

120.5

150

75

2950

CDL150-60 multi-stage centrifugal pump

130

150

75

2950

CDL200-10-B multi-stage centrifugal pump

20

200

18.5

2950

CDL200-10-A multi-stage centrifugal pump

24

200

22

2950

CDL200-10 multi-stage centrifugal pump

34

200

30

2950

CDL200-20-2B multi-stage centrifugal pump

41

200

37

2950

CDL200-20-2A multi-stage centrifugal pump

49

200

45

2950

CDL200-20-A multi-stage centrifugal pump

59

200

55

2950

CDL200-20 multi-stage centrifugal pump

69

200

55

2950

CDL200-30-2B multi-stage centrifugal pump

75

200

75

2950

CDL200-30-A-B multi-stage centrifugal pump

79

200

75

2950

CDL200-30-2A multi-stage centrifugal pump

84

200

75

2950

CDL200-30-B multi-stage centrifugal pump

89

200

75

2950

CDL200-30-A multi-stage centrifugal pump

93

200

75

2950

CDL200-30 multi-stage centrifugal pump

103

200

90

2950

CDL200-40-2B multi-stage centrifugal pump

110

200

90

2950

CDL200-40-2A multi-stage centrifugal pump

118

200

110

2950

CDL200-40-A multi-stage centrifugal pump

128

200

110

2950

CDL200-40 multi-stage centrifugal pump

138

200

110

2950

Please provide as much as possible for ordering:

1. Model 2. Diameter 3. Head (m) 4. Flow rate 5. Motor power (KW) 6. Speed (R/min) 7. Material without accessories 8. Voltage (V)

Welcome to visit our Quanda Pump Valve【www.quandabf.cn】If you have any questions You can call us and we will do our best to provide you with high-quality service.