CHL stainless steel multi-stage centrifugal pump

NegotiableUpdate on 03/13
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Brand: Quanda Pump Valve Address: Oubei Town, Yongjia County, Wenzhou City, Zhejiang Province Model: CHL stainless steel multi-stage centrifugal pump for thin, clean, non condensable, non explosive, solid particle or fiber free liquids. Liquid temperature: Room temperature type -15 ℃ to+70 ℃ Hot water type CHL stainless steel multi-stage pump+70 ℃ to+110 ℃ Maximum ambient temperature:+40 ℃ Maximum operating pressure: 10 bar Maximum inlet pressure limited by maximum operating pressure Medium acidity and alkalinity: PH4~9
Product Details

CHL stainless steel multi-stage centrifugal pumpAdopting maintenance free mechanical seals. The overcurrent components of the pump are made of stainless steel materials (304 or 316), which have the characteristics of low noise, light corrosion resistance, beautiful appearance, small size, light weight, and long service life.

Application scope of CHL stainless steel multi-stage centrifugal pump
CHL stainless steelmultistage centrifugal pumpMainly used for household central air conditioning circulation and industrial liquid transmission. Such as the circulation and pressurization of demineralized water, softened water, purification systems, light oil, etc.
1) Small central air conditioning cycle
2) Cooling system
3) Industrial cleaning
4) Water treatment (purification of water)
5) Aquaculture
6) Fertilization/metering system
7) Environmental Applications
Working conditions of CHL stainless steel multi-stage centrifugal pump
A liquid that is thin, clean, non condensable, non explosive, and does not contain solid particles or fibers.
Liquid temperature: Room temperature type -15 ℃ to+70 ℃
Hot water type CHL stainless steel multi-stage pump+70 ℃ to+110 ℃
Maximum ambient temperature:+40 ℃
Maximum operating pressure: 10 bar
The maximum import pressure is limited by the maximum operating pressure
Medium acidity and alkalinity: PH4~9
Internal structure of CHL stainless steel multi-stage centrifugal pump

http://www.quandabf.cn/duojibeng/pr_71.html

Number (NO)

Multi stage pump name

Material

1

Inlet and outlet section

Stainless steel

2

Connection pipe

Stainless steel

3

Clamp plate

Stainless steel

4

Impeller

Stainless steel

5

Shaft

Stainless steel

6

Gag (plug)

Stainless steel

7

Water out guide vane

Stainless steel

8

Mechanical seal


9

Motor end cover

Aluminum alloy

10

Base frame

Cast iron

11

Quick joint

Stainless steel

12

Guide vane

Stainless steel

13

Support guide vane

Stainless steel

14

Induccr

Stainless steel

The significance of CHL stainless steel multi-stage centrifugal pump model
http://www.quandabf.cn/duojibeng/pr_71.html
CHL stainless steel multi-stage centrifugal pump selection parameters

model

Head (m)

Flow rate (m3/h)

Motor power (KW)

Speed (r/min)

CHL2-20

14

2

0.37

2900

CHL2-30

21

2

0.55

2900

CHL2-40

28

2

0.55

2900

CHL2-50

35

2

0.55

2900

CHL2-60

42

2

0.75

2900

CHL4-20

15

4

0.55

2900

CHL4-30

22

4

0.75

2900

CHL4-40

30

4

0.75

2900

CHL8-10

8.5

8

0.75

2900

CHL8-20

17

8

0.75

2900

CHL8-30

25.5

8

1.1

2900

CHL8-40

34

8

1.5

2900

CHL8-50

42.5

8

2.2

2900

CHL12-10

9.5

12

0.75

2900

CHL12-20

19.5

12

1.2

2900

CHL12-30

29.5

12

1.8

2900

CHL12-40

39.5

12

2.4

2900

CHL12-50

50

12

3

2900

CHL16-10

10

16

1.1

2900

CHL16-20

21

16

2.2

2900

CHL16-30

32

16

3

2900

CHL20-10

9.5

20

1.1

2900

CHL20-20

21

20

2.2

2900

CHL20-30

33

20

4

2900

CHLF(T)2-20

14

2

0.37

2900

CHLF(T)2-30

21

2

0.55

2900

CHLF(T)2-40

28

2

0.55

2900

CHLF(T)2-50

35

2

0.55

2900

CHLF(T)2-60

42

2

0.75

2900

CHLF(T)4-20

15

4

0.55

2900

CHLF(T)4-30

22

4

0.55

2900

CHLF(T)4-40

30

4

0.75

2900

CHLF(T)4-50

38

4

1.1

2900

CHLF(T)4-60

45

4

1.1

2900

CHLF(T)8-10

8.5

8

0.75

2900

CHLF(T)8-20

17

8

0.75

2900

CHLF(T)8-30

25.5

8

1.1

2900

CHLF(T)8-40

34

8

1.5

2900

CHLF(T)8-50

42.5

8

2.2

2900

CHLF(T)12-10

9.5

12

0.75

2900

CHLF(T)12-20

19.5

12

1.2

2900

CHLF(T)12-30

29.5

12

1.8

2900

CHLF(T)12-40

39.5

12

2.4

2900

CHLF(T)12-50

50

12

3

2900

CHLF(T)16-10

10

16

1.1

2900

CHLF(T)16-20

21

16

2.2

2900

CHLF(T)16-30

32

16

3

2900

CHLF(T)16-40

43

16

4

2900

CHLF(T)20-10

9.5

20

1.1

2900

CHLF(T)20-20

21

20

2.2

2900

CHLF(T)20-30

33

20

4

2900

CHLF(T)20-40

44.5

20

4.4

2900

Requirements for CHL stainless steel multi-stage centrifugal pump motor
The motor is a fully enclosed, air-cooled bipolar motor
Protection level: IP55
Insulation level: F
Standard voltage,
50Hz:
1×220-240V
3×220-240V
380-415V
Maintenance work of CHL stainless steel multi-stage centrifugal pump
1. The inlet pipeline of CHL type stainless steel multi-stage pump must be highly sealed to prevent water and air leakage.
2. CHL type stainless steel multi-stage pumps are prohibited from operating for a long time under cavitation conditions.
3. Prohibit CHL stainless steel multi-stage pumps from operating with motor overcurrent for extended periods of time during high flow operation.
4. Regularly check the motor current value during the operation of CHL stainless steel multi-stage pump, and try to keep the pump running within the design operating range as much as possible;
5. CHL stainless steel multi-stage pumps should be supervised by dedicated personnel during operation to prevent accidents.
6. The CHL stainless steel multi-stage pump should be lubricated with oil on the bearings every 500 hours of operation.
7. After long-term operation of CHL stainless steel multi-stage pump, if the noise and vibration of the unit increase due to mechanical wear, it should be stopped for inspection. If necessary, vulnerable parts and bearings can be replaced. The overhaul period of the unit is generally one year.
Maintenance of mechanical seal for CHL stainless steel multi-stage pump
1. The mechanical seal lubrication of CHL stainless steel multi-stage pump should be clean and free of solid particles.
2. It is strictly prohibited for mechanical seals to work under dry grinding and idling conditions.
3. Before starting, the pump (motor) should be turned a few times to avoid sudden starting causing damage to the sealing ring.

Please provide as much as possible for ordering:

1. Model 2. Diameter 3. Head (m) 4. Flow rate 5. Motor power (KW) 6. Speed (R/min) 7. Material 8. Voltage (V)

Welcome to visit our Quanda Pump Valve【www.quandabf.cn】If you have any questions You can call us and we will do our best to provide you with high-quality service.