1、 Product Introduction: CIC-D120 ion chromatograph is a high stability ion chromatograph with circuit upgrade. It is equipped with a bipolar conductivity detector, which greatly improves the detection performance and stability of the instrument, providing customers with the ultimate user experience. The instrument is equipped with an independently developed observatory intelligent workstation, which not only enables intelligent control of instrument functional components, but also has powerful data processing capabilities; In addition, it can also be compatible with external devices such as amperometric detectors, ultraviolet detectors, and UV post column derivatization. Combined with Shenghan's leading chromatographic column technology, it can achieve analysis of anions and cations, cyanide ions, iodide ions, sugars, small molecule organic acids, etc. It is widely applicable in the fields of environment, disease control, food, chemical industry, electronics, mining and metallurgy. 2、 Product parameters
Product Details
  • 1、 Product Introduction
    The CIC-D120 ion chromatograph is a high stability ion chromatograph with circuit upgrade, equipped with a bipolar conductivity detector, which greatly improves the detection performance and stability of the instrument, providing customers with the ultimate user experience. The instrument is equipped with an independently developed observatory intelligent workstation, which not only enables intelligent control of instrument functional components, but also has powerful data processing capabilities; In addition, it can also be compatible with external devices such as amperometric detectors, ultraviolet detectors, and UV post column derivatization. Combined with Shenghan's leading chromatographic column technology, it can achieve analysis of anions and cations, cyanide ions, iodide ions, sugars, small molecule organic acids, etc. It is widely applicable in the fields of environment, disease control, food, chemical industry, electronics, mining and metallurgy.
    2、 Product parameters

    parts

    technical parameter

    host

    CIC-D120

    Infusion pump

    model: SH-120A
    Maximum pressure resistance: 35MPa (PEEK material); Flow range: 0.001-9.999mL/min
    Pressure display accuracy: ≤ 0.1MPa; Pressure pulsation: ≤ 0.5%
    Allowable error of flow setting value: (0.2-0.5) mL/min, ± 5%;
    0.5-1.0)mL/min,±3%;
    Greater than 1.0mL/min, ± 2%
    Traffic stability: (0.2-0.5)mL/min≤3%;
    0.5-1.0)mL/min≤2%;
    Greater than 1.0mL/min ≤ 2%

    Six way valve

    FLOM solenoid valve: VF-02-1107
    Maximum pressure resistance: 35MPa; Control mode: stepper motor control
    Rotor contact material: PEEK; Power supply: 24V DC power supply

    Conductivity cell

    Bipolar constant temperature conductivity cell: SHD-6
    Conductivity cell electrode: passivated 316 stainless steel
    Pool volume: ≤ 0.8μL; Detection range: 0-45000 μ S/cm;

    Detection resolution: 0.0020nS/cm; Output voltage:- 6000~+6000mV adjustable
    Baseline noise: ≤ 0.05%FS; Baseline drift: ≤ 3%FS/30min
    Constant temperature accuracy: 5-60 ± 0.01 ℃; Maximum withstand voltage: 10MPa
    Minimum detection limit: Cl-≤0.0005μg/mL
    Li+≤0.001μg/mL
    BrO3-≤0.001μg/mL
    Linear range: ≥ 103; Instrument linearity: ≥ zero point nine nine nine

    Qualitative repeatability: ≤ 1.0%; Quantitative repeatability: ≤ 1%

    Suppressor

    Anion inhibition function: compatible with carbonate, hydroxide systems and other eluents
    Advanced continuous self regenerating micro film electrochemical suppression technology, without the need for additional regeneration fluid;
    High inhibitory capacity, low background conductivity;
    Low noise, good stability;
    High pressure resistance, no leakage at up to 6MPa, normal operation at 2MPa;
    Smaller dead volume, more sensitive response signal;

    Cation inhibition function: compatible with leaching solutions such as nitric acid and methane sulfonic acid systems
    Advanced continuous self regenerating micro film electrochemical suppression technology, without the need for additional regeneration fluid;
    High inhibitory capacity, low background conductivity;
    Low noise, good stability;
    High pressure resistance, no leakage at up to 6MPa, normal operation at 2MPa;
    Smaller dead volume, more sensitive response signal;

    Column temperature box

    Heating method: Built in circulating three-dimensional constant temperature column temperature box
    Temperature control range: 20-60 ℃
    Allowable error of temperature setting value for column temperature box: ± 2 ℃; Temperature control accuracy: ± 0.01 ℃
    Temperature stability: 1 ℃/h

    [Optional] Rinse solution generator|

    [Optional] Rinse solution generator (external) SHRF-10
    Type of rinsing solution: KOH/NaOH; Concentration range of rinsing solution: 0.1-120.0mM
    Concentration increment: 0.1mM; Flow rate range: 0.1-5.0mL/min
    Concentration control accuracy: ± 0.1mM; Maximum operating pressure: 20MPa; Minimum operating pressure: 5MPa

    workstation

    Observatory Intelligent Workstation
    Integrating data collection, instrument control and monitoring, data analysis, and report output;
    Multiple data acquisition interfaces (A/D analog acquisition card, network USB、RD232);
    Compatible with various detectors, automatic samplers, rinse solution generators, etc;
    Customized graphics, simplified operation process, and improved user experience.

    [Optional] Low pressure degassing

    Vacuum degree:- 70KPa; Internal volume: 300 μ L; Organic tolerance: 100%
    Maximum flow rate: 10mL/min; Degassing efficiency: 90% degassing at 1.0mL/min;

    Degassing volume: 7.5mL


    3、 Product Features
    1. Temperature controlled bipolar conductivity detector, with a larger detection range and better analysis accuracy;
    2. Built in cyclic stereoscopic constant temperature technology, fast constant temperature time, ensuring accurate and reliable experimental data;
    3. National major specialized engineering manufacturing technology to maintain excellent system stability;
    4. Integrated host, modular design, plug and play, automatic recognition, easy operation;
    5. The double plunger parallel flow pump is equipped with a gas-liquid separator, which allows for self degassing and flushing of the flow path, eliminating the need for manual maintenance;
    6. Fully plasticized flow path system, equipped with unique online degassing and gas-liquid separation integrated technology, further ensuring data accuracy;
    7. Continuous automatic regeneration of micro film suppressor, high voltage resistance, small dead volume, and corresponding high signal;
    8. We have independently developed an internationally leading full range of chromatography columns with high column efficiency, large capacity, and the ability to detect various component ions.

    Juchuang Environmental Protection provides you with comprehensive technical support and perfect after-sales service! Details consultation:


  • 1. Temperature controlled bipolar conductivity detector, with a larger detection range and better analysis accuracy;
    2. Built in cyclic stereoscopic constant temperature technology, fast constant temperature time, ensuring accurate and reliable experimental data;
    3. National major specialized engineering manufacturing technology to maintain excellent system stability;
    4. Integrated host, modular design, plug and play, automatic recognition, easy operation;
    5. The double plunger parallel flow pump is equipped with a gas-liquid separator, which allows for self degassing and flushing of the flow path, eliminating the need for manual maintenance;
    6. Fully plasticized flow path system, equipped with unique online degassing and gas-liquid separation integrated technology, further ensuring data accuracy;
    7. Continuous automatic regeneration of micro film suppressor, high voltage resistance, small dead volume, and corresponding high signal;
    8. We have independently developed an internationally leading full range of chromatography columns with high column efficiency, large capacity, and the ability to detect various component ions.

  • parts

    technical parameter

    host

    CIC-D120

    Infusion pump

    model: SH-120A
    Maximum pressure resistance: 35MPa (PEEK material); Flow range: 0.001-9.999mL/min
    Pressure display accuracy: ≤ 0.1MPa; Pressure pulsation: ≤ 0.5%
    Allowable error of flow setting value: (0.2-0.5) mL/min, ± 5%;
    0.5-1.0)mL/min,±3%;
    Greater than 1.0mL/min, ± 2%
    Traffic stability: (0.2-0.5)mL/min≤3%;
    0.5-1.0)mL/min≤2%;
    Greater than 1.0mL/min ≤ 2%

    Six way valve

    FLOM solenoid valve: VF-02-1107
    Maximum pressure resistance: 35MPa; Control mode: stepper motor control
    Rotor contact material: PEEK; Power supply: 24V DC power supply

    Conductivity cell

    Bipolar constant temperature conductivity cell: SHD-6
    Conductivity cell electrode: passivated 316 stainless steel
    Pool volume: ≤ 0.8μL; Detection range: 0-45000 μ S/cm;

    Detection resolution: 0.0020nS/cm; Output voltage:- 6000~+6000mV adjustable
    Baseline noise: ≤ 0.05%FS; Baseline drift: ≤ 3%FS/30min
    Constant temperature accuracy: 5-60 ± 0.01 ℃; Maximum withstand voltage: 10MPa
    Minimum detection limit: Cl-≤0.0005μg/mL
    Li+≤0.001μg/mL
    BrO3-≤0.001μg/mL
    Linear range: ≥ 103; Instrument linearity: ≥ zero point nine nine nine

    Qualitative repeatability: ≤ 1.0%; Quantitative repeatability: ≤ 1%

    Suppressor

    Anion inhibition function: compatible with carbonate, hydroxide systems and other eluents
    Advanced continuous self regenerating micro film electrochemical suppression technology, without the need for additional regeneration fluid;
    High inhibitory capacity, low background conductivity;
    Low noise, good stability;
    High pressure resistance, no leakage at up to 6MPa, normal operation at 2MPa;
    Smaller dead volume, more sensitive response signal;

    Cation inhibition function: compatible with leaching solutions such as nitric acid and methane sulfonic acid systems
    Advanced continuous self regenerating micro film electrochemical suppression technology, without the need for additional regeneration fluid;
    High inhibitory capacity, low background conductivity;
    Low noise, good stability;
    High pressure resistance, no leakage at up to 6MPa, normal operation at 2MPa;
    Smaller dead volume, more sensitive response signal;

    Column temperature box

    Heating method: Built in circulating three-dimensional constant temperature column temperature box
    Temperature control range: 20-60 ℃
    Allowable error of temperature setting value for column temperature box: ± 2 ℃; Temperature control accuracy: ± 0.01 ℃
    Temperature stability: 1 ℃/h

    [Optional] Rinse solution generator|

    [Optional] Rinse solution generator (external) SHRF-10
    Type of rinsing solution: KOH/NaOH; Concentration range of rinsing solution: 0.1-120.0mM
    Concentration increment: 0.1mM; Flow rate range: 0.1-5.0mL/min
    Concentration control accuracy: ± 0.1mM; Maximum operating pressure: 20MPa; Minimum operating pressure: 5MPa

    workstation

    Observatory Intelligent Workstation
    Integrating data collection, instrument control and monitoring, data analysis, and report output;
    Multiple data acquisition interfaces (A/D analog acquisition card, network USB、RD232);
    Compatible with various detectors, automatic samplers, rinse solution generators, etc;
    Customized graphics, simplified operation process, and improved user experience.

    [Optional] Low pressure degassing

    Vacuum degree:- 70KPa; Internal volume: 300 μ L; Organic tolerance: 100%
    Maximum flow rate: 10mL/min; Degassing efficiency: 90% degassing at 1.0mL/min;

    Degassing volume: 7.5mL