Qingdao Juchuang Environmental Protection Group Co., Ltd
15588680396
No. 23, Siliu North Road, Licang District, Qingdao City
1、 Product Introduction
The CIC-D160 ion chromatograph is a high stability ion chromatograph with circuit upgrade, equipped with a bipolar conductivity detector, which greatly improves the detection performance and stability of the instrument, bringing the ultimate user experience. The CIC-D160 ion chromatograph is equipped with a built-in eluent generator, which can generate the required concentration of eluent online by introducing pure water. It can achieve gradient elution and complex sample detection that cannot be completed by isocratic elution. It is widely used in various fields such as environment, chemical industry, food, power, electronics, mining and metallurgy.
2、 Product parameters
|
parts |
technical parameter |
|
host |
CIC-D160 |
|
Infusion pump |
Pump type: chemically inert non-metallic undamped pump head, PEEK tubing, suitable for pH 0-14 rinsing solution and reverse phase organic solvents, capable of automatic plunger cleaning Maximum pressure resistance: 35MPa (PEEK material) Flow range: 0.001-9.999mL/min Pressure display accuracy: ≤ 0.1MPa pressure pulsation: ≤ 0.5% Allowable error of flow setting value: (0.2-0.5) mL/min, ± 5%; (0.5-1.0)mL/min,±3%; Greater than 1.0mL/min, ± 2% Traffic stability: (0.2-0.5)mL/min≤3%; (0.5-1.0)mL/min≤2%; Greater than 1.0mL/min ≤ 2 |
|
Six way valve |
Solenoid valve: VF-02-1107 Maximum withstand voltage: 35MPa Control mode: Stepper motor control Rotor contact material: PEEK Power supply: 24V DC power supply |
|
Conductivity cell |
Temperature control compensation technology ensures more accurate temperature control and more stable detection results. Structure: Bipolar shielded conductivity cell (passivated 316 stainless steel) Pool volume: ≤ 0.8μL; Detection range: 0-50000 μ S/cm; Detection resolution: 0.0020nS/cm Output voltage:- 6000~+6000mV adjustable Baseline noise: ≤ 0.05% FS baseline drift: ≤ 3%FS/30min Constant temperature accuracy: 5-60 ± 0.01 ℃ Maximum withstand voltage: 10MPa Minimum detection limit: Cl-≤0.0005μg/mL Li+≤0.001μg/mL BrO3-≤0.001μg/mL Linear range: ≥ 103 Instrument linearity: ≥ zero point nine nine nine Qualitative repeatability: ≤ 1.0% Quantitative repeatability: ≤ 1% |
|
Suppressor |
Anion inhibition function: compatible with carbonate, hydroxide systems and other eluents |
|
|
Cation inhibition function: compatible with leaching solutions such as nitric acid and methane sulfonic acid systems |
|
Column temperature box |
Heating method: Built in circulating three-dimensional constant temperature column temperature box |
|
Rinse solution generator |
Equal elution results in higher consistency among different batches of samples; Gradient elution is used to complete complex sample detection that cannot be achieved by isotropy. Rinsing solution type: KOH/NaOH Rinsing solution concentration range: 0.1-120.0mM Concentration increment: 0.1mM Concentration control accuracy: ± 0.1mM Maximum operating pressure: 20MPa Minimum operating pressure: 5MPa Flow rate range: 0.1-5.0mL/min |
|
Low pressure degassing |
Built in low-pressure degassing device Vacuum degree:- 70 kPa maximum flow rate: 10 mL/min Internal volume: 300 μ L Degassing efficiency: 90% degassing at 1 mL/min |
|
workstation |
Integrating data collection, instrument control and monitoring, data analysis, and report output; |
1. Three sided heating with uniform temperature
2. Microcomputer controller, uniform heating, stable temperature control
3. Mirror stainless steel inner liner, durable and long-lasting
4. Thickened insulation layer for higher heating efficiency