CLX residual chlorine/total chlorine analyzer

NegotiableUpdate on 05/26
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
CLX online residual chlorine analyzer, using DPD analysis method, is mainly used in the fields of drinking water, river water, reclaimed water reuse, sewage, etc.
Product Details
CLX online residual chlorine analyzer, using DPD analysis method, is mainly used in the fields of drinking water, river water, reclaimed water reuse, sewage, etc.
Instrument characteristics
• Measurement of residual chlorine or total chlorine
• Easy to operate -30 days maintenance free
DPD standard colorimetric method
• User selects measurement cycle
• 2 programmable alarms
4-20mA and RS-485 MODBUS outputs
• Recognized by USEPA
TECHNICAL INDEX

The residual chlorine measuring instrument CLX measures free chlorine or total chlorine according to the DPD method, with a measurement range of 0-10 mg/l. The residual chlorine measuring instrument includes a power supply, optical sensor, and display screen, and is installed in an IP66 corrosion-resistant housing. The measurement reading is the same as the laboratory/portable photoelectric colorimetric residual chlorine meter. The output has standard 4-20mA and RS485 Modubs. The residual chlorine measuring instrument has a movable measuring slot and a transparent window in the optical part, which can clearly observe the reaction of the sample and reagent. The measurement accuracy is ± 5% (measurement range 0-6 mg/l) and ± 10% (measurement range 6-10 mg/l), respectively. The residual chlorine measuring instrument has a selectable measurement cycle time - from 110 seconds to 10 minutes. The unmanned operation time is at least 30 days. The reagents are ordered separately and supplied in powder form. They should be filled with water before use.

Technical Parameter

measuring principle

DPD standard method for measuring residual chlorine or total chlorine

measuring range

0~10 mg/L Cl2(ppm)

measurement accuracy

0~6.00 mg/L Cl2(ppm)

± 5% reading or ± 0.03 mg/L Cl2 (ppm) whichever is greater

6.01~10.00 mg/L Cl2(ppm)

± 10% reading

resolution

0.01 mg/L Cl2(ppm)

Measurement period

Adjustable: 110 seconds to 10 minutes (default value: 2.5 minutes)

display

LCD backlit display

call the police

2-channel programmable 240VAC 2A

standard output

Isolated 4-20 mA and bidirectional RS 485 Modbus

operate temperature

5~40℃

Sample pressure

0.34~10.3 bar

Sample flow rate

200~400 mL/min

power supply

100~240 VAC,47~63 Hz,150VA

protection grade

IP 66

authentication

CE certification, ETL UL61010B-1,ETLc CSA 22.2 No. 101-1-92

weight

3.6 kg without reagents

External dimensions

406 mm × 406 mm × 229 mm