Model significance

Product Introduction
The CWB magnetic chemical vortex pump (referred to as the magnetic vortex pump) is a new product that applies the working principle of permanent magnet couplings to centrifugal pumps. It has a reasonable design, advanced technology, full sealing, no leakage, low flow rate, high head, and corrosion resistance. Its performance has reached the advanced level of similar foreign products. Magnetic pumps replace dynamic seals with static seals, ensuring that the overcurrent components of the pump are in a completely sealed state, completely solving the problems of running, emitting, and dripping that cannot be avoided by other pump mechanical seals. The CWB magnetic chemical vortex pump uses corrosion-resistant and high-strength engineering plastics, corundum ceramics, stainless steel and other materials as manufacturing materials, so it has good corrosion resistance and can protect the transported medium from pollution.
Product Features
The CWB magnetic chemical vortex pump adopts a magnetic transmission structure to ensure that the pump can be sealed and achieve leak free transportation of corrosive, flammable, explosive, toxic and other chemical media.
1. High head, low flow rate, with a specific speed generally less than 40;
2. Simple structure, small size, and light weight;
3. The CWB magnetic chemical vortex pump has a self-lubricating circuit to improve the service life of sliding bearings;
4. Add a cooling circuit to promptly remove magnetic eddy current heat;
5. The CWB magnetic chemical vortex pump adopts cantilever blades to reduce the radial force of the impeller;
6. As the viscosity of the conveying medium increases, the efficiency of the CWB magnetic chemical vortex pump decreases sharply. Therefore, the viscosity of the medium should not exceed 5 × 10-6 M3/S.
Product Usage
Magnetic pump has a compact structure, beautiful appearance, small volume, low noise, reliable operation, and easy use and maintenance. Can be widely used in chemical, pharmaceutical, petroleum, reliable, and easy to use and maintain. It can be widely used in chemical, pharmaceutical, petroleum, acid and alkali pumping, oil, rare and valuable liquids, venom, volatile liquids, as well as supporting circulating water equipment and filter machines. Especially for the pumping of liquids that are prone to leakage, flammable, and explosive, this pump is more ideal.
structural diagram
![]() |
1 |
pump body |
9 |
pump shaft |
2 |
impeller |
10 |
Internal magnetic rotor |
|
3 |
pump cover |
11 |
Inner rotor nut |
|
4 |
impeller nut |
12 |
isolating sleeve |
|
5 |
thrust ring |
13 |
External magnetic assembly |
|
6 |
sealing ring |
14 |
connection frame |
|
7 |
Sliding bearing sleeve |
15 |
motor |
|
8 |
bushing |
performance parameters
model |
Traffic Q (m3/h) |
head (m) |
Speed n (r/min) |
Efficiency η (%) |
Motor power (KW) |
CWB20-20 |
0.72 |
20 |
2900 |
22 |
1.1 |
CWB20-40 |
0.72 |
40 |
2900 |
18 |
1.1 |
CWB20-65 |
0.72 |
65 |
2900 |
15 |
2.2 |
CWB25-25 |
1.44 |
25 |
2900 |
26 |
1.1 |
CWB25-40 |
1.44 |
40 |
2900 |
24 |
1.5 |
CWB25-75 |
1.44 |
75 |
2900 |
20 |
4 |
CWB32-30 |
2.88 |
30 |
2900 |
28 |
2.2 |
CWB32-50 |
2.88 |
50 |
2900 |
26 |
3 |
CWB32-75 |
2.88 |
75 |
2900 |
22 |
5.5 |
CWB32-120 |
2.88 |
120 |
2900 |
18 |
7.5 |
CWB40-40 |
5.4 |
40 |
2900 |
30 |
5.5 |
CWB40-90 |
5.4 |
90 |
2900 |
26 |
11 |
CWB50-45 |
9 |
45 |
2900 |
30 |
7.5 |
CWB65-50 |
14.4 |
50 |
2900 |
35 |
15 |
Note: The materials of the overcurrent components are 304, 304L, 316, and 316L, and non-standard magnetic vortex pumps can be customized according to customer requirements. |
|||||
Fault causes and troubleshooting methods
failure mode |
root cause |
exclusion method |
The pump is not producing water |
1. Reverse rotation of water pump 2. Air leakage in the inlet pipeline 3. Insufficient water storage in the pump chamber 4. The voltage is too high, causing the coupling to slip during startup 5. The suction distance is too high |
1. Change the motor wiring 2. Eliminate air leakage 3. Increase water storage capacity 4. Adjust the voltage 5. Lower the installation position of the pump |
insufficient traffic |
1. The suction pipe diameter is too small 2. Channel blockage 3. High head 4. The speed is too low |
1. Replace the inlet pipe 2. Clean the flow channel 3. Turn up the outlet valve 4. Restore the rated speed |
Low head |
1. Excessive traffic 2. The speed is too low |
1. Turn down the outlet valve 2. Restore the rated speed |
The noise is too loud. |
1. Severe wear of the shaft 2. Severe wear of the shaft sleeve 3. Drive the magnetic steel cup to contact the isolation sleeve |
1. Replace the pump shaft 2. Replace the shaft sleeve 3. Dismantle the pump head and reassemble it |
leakage |
Seal ring damaged | Replace the sealing ring |