NK-301F electrolytic micro water analyzerChlorine water content online analyzer, is a trace water analysis instrument developed by our company specifically for detecting the moisture content of highly corrosive gases such as liquid chlorine and hydrogen chloride. Using the P2O5 electrolysis method, it complies with national standards such as GBT 5138-2021 Industrial Liquid Chlorine and HGT3941-2007 Determination of Moisture Content in Industrial Liquid Chlorine Electricity Method. It can measure trace moisture content in various corrosive gases such as chlorine, hydrogen fluoride, hydrogen chloride, and hydrogen bromide (excluding gases that react with phosphoric acid such as ammonia).
Typical application areas:
>Chlor alkali industry
>Measurement of trace water in various corrosive gasesChlorine water content online analyzer
Instrument features:
Ø Split type, display unit and detection unit are designed separately to prevent corrosion caused by sample gas
Ø The materials used for the air circuit and other components of the entire machine are corrosion-resistant
Ø Large screen dot matrix LCD display, display unit selectable in ppm
Ø Automatic real-time recording of measurement data
Special gas path and program design, sensor sealing protection, stable overall performance
Following standards:
GB/T 5832.1-2016 "Gas analysis - Determination of trace moisture - Part 1: Electrolytic method"
Ø GBT 5138-2021 "Industrial Liquid Chlorine"
HGT 3941-2007 "Determination of moisture content in industrial liquid chlorine - Electricity method"
Technical Specifications:
>Analysis principle: Principle of electrolytic method for phosphorus pentoxide
>Range: 0-2000ppm (intermediate range can be customized)
>Accuracy: ≤ 5% FS for soil
>Repeatability: ≤± 0.5% F.S
>Stability: ≤± 2% F.S/7d
>Resolution: 1ppm
>Response time: T90 ≤ 10min>
>Working environment: Temperature range of -25 ℃ to+55 ℃; Humidity ≤ 90% RH (no condensation)
>Sample gas pressure: 0.05 MPa ≤ inlet pressure ≤ 0.1 MPa (outlet must be at atmospheric pressure)
>Sample gas flow rate: 100ml/min
>Working power supply: 220VAC ± 10%, 50Hz ± 5% (charging power supply); The instrument comes with a rechargeable battery
>Data records: 3000 records
>Display unit: Volume ratio (ppm/v),%
>Alarm method: beep sound alarm, alarm limit can be set arbitrarily within the range
>Operation method: button operation
>External dimensions:
Display unit 260mm (width) × 160mm (height) × 300mm (depth)
Analysis unit 300mm (width) x 400mm (height) x 200mm (depth)
>Weight:
Display unit weighs approximately 1.5kg
The detection unit weighs approximately 3.5kg