Circular Solid Phase Extraction Device

NegotiableUpdate on 02/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The circular solid-phase extraction device JC-GX-36S allows the liquid sample solution to pass through the adsorbent, retaining the analyte. Then, an appropriate strength solvent is selected to remove impurities, and a small amount of solvent is quickly used to elute the analyte, thereby achieving rapid separation, purification, and concentration.
Product Details

1、 Product Introduction

Circular Solid Phase Extraction DeviceJC-GX-36S, Pass the liquid sample solution through an adsorbent to retain the analyte, then use a solvent of appropriate strength to remove impurities, and quickly elute the analyte with a small amount of solvent to achieve rapid separation, purification, and concentration. At present, it is mainly used in the analysis of organic substances such as polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs) in water, pesticide and herbicide residue analysis in fruits, vegetables and food, antibiotic analysis, clinical drug analysis, etc. in China.

2、 Product parameters

1. Sample quantity: 36
2. Control mode: Independent control
3. Pressure display: with pressure gauge
4. Vacuum degree: 0.098Mpa
5. Flow control valves: 36 pieces
6. Work area size: Φ 280X138 (mm)

3、 Product Features

1Circular Solid Phase Extraction DeviceThe whole machine is made of transparent organic glass with strong corrosion resistance.
2. The vacuum chamber has a uniform wall thickness, so it can withstand high negative pressure above -0.096Mpa, and will not deform after long-term high-pressure use.
3. Uniform compression throughout, good air tightness, and strong stability.
4. Good consistency in extraction speed and easy control and adjustment.
5. Multi channel can be independently controlled, and the joints are corrosion-resistant.
6. The internal test tube rack of the solid-phase extraction instrument is made of polytetrafluoroethylene, which has high corrosion resistance.