Controllable temperature petroleum water and electricity analyzer

NegotiableUpdate on 04/15
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The DTS-6 controllable temperature petroleum water electrolysis analyzer can set the required control temperature through the buttons on the temperature controller panel; The required time can also be set through the digital dial on the timer panel. When the set time is reached, the red light on the controller will turn on, and the indicator light on the dehydration switch will change from on to off. You need to turn off the dehydration switch and then turn it on again to start a new round of dehydration.
Product Details

Controllable temperature petroleum water and electricity analyzerMain performance indicators

1. Analysis scope:0100

2. Analysis error: ±1

3. Analysis time:510 min

4. Sample size for analysis:550740 mL(Measuring cylinder capacity800Milliliters)

5. Dehydration power consumption: ≤15W

6. Heating power consumption: ≤150W

7. Set temperature range: room temperature~95

8. Set time range:1min99min

9. Power supply:AC 220V±10%,50 Hz

Controllable temperature petroleum water and electricity analyzerPrecautions

1. This instrument is not an explosion-proof instrument, so it is strictly prohibited to use it in environments containing explosive gases.

2. The heating and dehydration electrode of this instrument should not be dry burned in the air to prevent damage to the heating and dehydration electrode.

3. Be careful and cautious during the operation of the instrument to prevent tipping over the measuring cylinder and causing a fire.

4. During the dehydration process, the heating of the oil sample should be set appropriately, and the oil sample should not be allowed to boil violently and overflow. If the oil sample boils, the heating switch can be turned off. If the oil sample cannot be prevented from overflowing, the dehydration switch can be quickly turned off and the heating dehydration electrode can be pulled out of the measuring cylinder.

5. During the dehydration process, do not touch the exposed metal parts of the inner and outer electrodes with your hands to avoid electric shock (the current is extremely low and there is no danger to life).

6. After dehydration, be sure to turn off the dehydration and heating switches first, and then remove the dehydration electrode.