Submersible sewage pump model |
internet traffic |
lift |
power |
rotational speed |
voltage |
Equipped with inner diameter of rubber hose |
|
AS10-2W/CBsubmersible sewage pump |
15 |
4 |
1.1 |
2850 |
380 |
76 |
|
AS10-2CBsubmersible sewage pump |
15 |
4.5 |
1.1 |
2850 |
380 |
76 |
|
AS16-2CBsubmersible sewage pump |
29 |
7.6 |
1.5 |
2850 |
380 |
76 |
|
AS30-2CBsubmersible sewage pump |
42 |
11 |
3 |
2850 |
380 |
76 |
|
AS55-2CBsubmersible sewage pump |
45 |
13 |
5.5 |
2900 |
380 |
127 |
|
AS55-4CBsubmersible sewage pump |
100 |
7.5 |
5.5 |
1450 |
380 |
152 |
|
AS75-2CBsubmersible sewage pump |
60 |
18 |
7.5 |
2900 |
380 |
127 |
|
AS75-4CBsubmersible sewage pump |
145 |
10 |
7.5 |
1450 |
380 |
152 |
|
AV14-4submersible sewage pump |
22 |
5.8 |
1.5 |
1450 |
380 |
76 |
|
AV55-2submersible sewage pump |
30 |
20 |
5.5 |
2900 |
380 |
76 |
|
AV75-2submersible sewage pump |
30 |
25 |
7.5 |
2900 |
380 |
76 |
|
|
1 |
base |
10 |
cable |
|
2 |
pump body |
11 |
Upper cover |
|
|
3 |
Bearing body |
12 |
bearing |
|
|
4 |
axle |
13 |
mechanical seal |
|
|
5 |
lip seal |
14 |
flat key |
|
|
6 |
motor housing |
15 |
IMPELLER NUT |
|
|
7 |
Stator core |
16 |
impeller |
|
|
8 |
Rotor core |
17 |
bent pipe |
|
|
9 |
Incoming line sealing |
|
|

|
Reason for malfunction |
cause analysis |
processing method |
|
The flow rate or head of the pump decreases |
1.Pump reversal 2The conveying head is too high. 3The suction medium goes through a bypass. 4The water outlet pipe is leaking. 5The outlet pipe may be partially blocked by sediment 6The pump is partially blocked. 7Impeller/The base is worn. |
1Turn off the main power supply of the control box and replace any two-phase power lines. 2、 Check:aIs the selected pump model correct. bIs the size of the water outlet pipe correct. 3、 Check if the valve is closed tightly, and then fully load test the pump. 4、 Identify the leak and make corrections accordingly. 5、 Inspect pipelines, clean or replace with new ones. 6、 Lift the pump surge, and if the pump is placed inside the filter screen, it also needs to be inspected and cleaned 7、 Lift the pump to adjust the clearance or replace parts. |
|
No flow after pump operation |
1Air blockage. 2Check the water discharge valve. 3Pump reversal. |
1、aOpen and close the valve several times in succession. bStart and stop the pump several times, with a gap between each restart2—3minute cAccording to different installation methods, check whether an air release valve needs to be installed 2、aIf the valve is in the closed state, it should be opened. bIf the installation is reversed, it should be reversed again. |
|
The pump starts and stops too frequently |
1The distance set by the float switch is too short. 2The check valve is malfunctioning and cannot check back, causing the liquid to flow back into the sewage tank. |
1Reset the float switch to extend the running time. 2Inspect and repair. |
|
Stop the malfunction |
1Floating ball closes, pavilion stops'Malfunction”. 2The float on the float is stuck'work'where |
1Check and replace if necessary. 2If necessary, the position can be changed. |
|
After the pump is started, the circuit breaker/Overloader trips open |
1Low voltage. 2The voltage is too high. 3The wiring of the electric sarcasm is incorrect 4Mud has accumulated at the bottom of the snail shell or?It's sediment. |
1、aCheck the voltage of the control box. If the voltage is too low, it cannot be used temporarily.bIf the cable is too long and causes excessive voltage drop, the cable should be shortened as much as possible and thicker cables should be selected appropriately. 2Install a transformer and plug the voltage hole into the specified range. 3Check the cable color codes and connector numbers in the control box and inspect the wiring 4Clean the pump and sewage tank, refer to the relevant sections in the installation instructions. |
|
The pump cannot be started, the fuse is blown or the circuit breaker is tripped |
1Floating ball malfunction. 2The winding, joint or cable is broken. 3The pump is blocked |
1Check if the bypass float switch can start the pump. If so, the float switch should be checked. 2Check with an ohmmeter. If it is proven to be a circuit, check the winding, terminals, and cables. 3Cut off the power, remove the pump from the sewage tank, clear obstacles, and try it out before resetting. |
|
The pump cannot start, but the fuse is not broken or the overload protector does not trip |
1No electricity. 2Windings, cables, connectors, or control switches are disconnected. |
1Check if the control box has power. 2Check the joints and windings of cables and motors. |
Please provide as much as possible for ordering:1. Model 2. Diameter 3. Head (m) 4. Flow rate 5. Motor power (KW) 6. Speed (R/min) 7. Material with accessories 8. Voltage (V)