D942X electric double eccentric soft seal butterfly valve $r $n Performance structure $r $n Its structure adopts a three-dimensional eccentric principle design, and a new processing technology that is compatible with elastic sealing and hard soft multi-layer sealing reduces the torque force of the butterfly valve during operation, achieving the functions of labor-saving and energy saving. Thus ensuring the overall reliability of corrosion resistance, high temperature resistance, and abrasion resistance. Applicable temperature: 0-80 ℃.
Product Details

D942X electricDouble eccentric soft sealbutterfly valve

Performance Structure

The structure adopts a three-dimensional eccentric principle design, and a new processing technology that is compatible with elastic sealing and hard soft multi-layer sealing, which reduces the torque force of the butterfly valve during operation, achieving the functions of labor-saving and energy saving. So as to ensure overall corrosion resistance and high temperature resistanceReliability against wear and tear. Applicable temperature:0-80℃. Electric Butterfly Valve Electric Flange Butterfly Valve D942X-16C Electric Butterfly Valve

Product Features

1. Adopting a three eccentric sealing structure, the valve seat and butterfly plate have almost no wear, and have a sealing function that becomes tighter and tighter as viewed

2. The sealing ring is made of stainless steel, which has the dual advantages of metal hard sealing and elastic sealing. It has excellent sealing performance in both low and high temperature conditions, with characteristics such as corrosion resistance and long service life

3. The sealing surface of the butterfly plate is made of welded cobalt based hard alloy, which is wear-resistant and has a long service life

4. The large-sized butterfly plate adopts a frame structure, with high strength, large overcurrent area, and low flow resistance

5. Metal hard sealed butterfly valve has bidirectional sealing function, which is not limited by the flow direction of the medium or the spatial position during installation, and can be installed in any direction

6. The drive device can be installed in multiple stations (rotated 90 ° or 180 °) for easy user use

Overall dimensions:

Nominal Diameter

structural length

H

Overall dimensions(Reference value)

DN

L

D343

D643

D943

millimetermm

inchinch

short series

Long series

H1

A1

B1

H2

A2

B2

H3

A3

B3

50

2

108

150

112

350

180

200

625

245

72

530

250

255

65

2 1/2

112

170

115

370

180

200

625

245

72

530

250

255

80

3

114

180

120

380

180

200

645

245

72

565

250

255

100

4

127

190

138

420

180

200

675

355

92

600

250

255

125

5

140

200

164

460

180

200

715

355

92

640

250

255

150

6

140

210

175

555

270

280

800

355

92

705

300

315

200

8

152

230

200

760

400

425

850

250

170

775

300

315

250

10

165

250

243

830

400

425

925

250

170

945

300

315

300

12

178

270

250

895

450

560

1035

450

220

1070

300

315

350

14

190

290

280

950

450

560

1075

450

220

1140

300

315

400

16

216

310

305

1190

535

580

1190

450

220

1210

300

315

450

18

222

330

350

1255

535

580

1250

650

280

1335

575

714

500

20

229

350

380

1305

535

580

1290

650

280

1415

575

714

600

24

267

390

445

1340

570

660

1455

850

380

1605

656

810

700

28

292

430

480

1520

750

550

1585

850

380

1844

656

810

800

32

318

470

530

1710

750

550

1700

1250

380

2040

656

810

900

36

330

510

580

1810

750

550

1965

1250

380

2255

785

863

1000

40

410

550

650

1960

900

750

2015

1250

380

2380

785

863

1200

48

470

630

760

2250

1000

925

2250

1250

380

2640

785

863

1400

56

530

710

850

2435

1000

925

-

-

-

2886

-

-

1600

64

600

790

1030

2780

1000

925

-

-

-

3156

-

-

1800

72

670

870

1230

3020

1100

980

-

-

-

3421

-

-

2000

80

760

950

1350

3270

1100

980

-

-

-

3685

-

-

Installation precautions:

1. Before installation, check whether the specifications, pressure, temperature, and corrosion resistance of the butterfly valve meet the requirements for use. Each component should be checked for damage or looseness.

2. This butterfly valve can be installed on pipelines at any angle and should be closed for installation; When welding pipeline flanges, the valve sealing port should be blocked with a plate to prevent particles and debris from damaging the sealing surface. After welding, remove the valve, clean the valve sealing surface and pipeline cavity, and then install and fix the valve.

3. Please pay attention to the direction of pressure when the valve is closed during installation.

4. Before installation, the sealing surfaces (end sealing surfaces, butterfly plate sealing surfaces, valve seat sealing surfaces) should be wiped clean to remove dust and dirt.

5. Before installation, the butterfly valve should be air tested, and its opening and closing should be flexible, with the opening and closing positions consistent with the pointer indication.

6. Manually operate clockwise to close, counterclockwise to open, and do not apply force to open or close the valve after the pointer indicates in place.

7. When conducting pressure tests on valves, it is not allowed to use a single flange for installation and pressure testing. Double flange installation and pressure testing must be used. The test pressure should comply with the GB/T13927-92 standard.

8. When tightening bolts, they should be tightened symmetrically and alternately, and it is not allowed to tighten them separately in sequence.

9. The limit screw has been adjusted before leaving the factory and should not be easily adjusted. If the driving device is configured as electric or pneumatic, please refer to the accompanying driving device manual.

10. The opening and closing stroke of the control mechanism of the electric butterfly valve has been adjusted before leaving the factory. To prevent directional errors when the power is turned on, users should manually turn it on to the half open position before the first power is turned on, and then press the jog switch to check that the direction of the indicator wheel is consistent with the direction of the valve opening.

11. If abnormal valve opening and closing is found, the cause should be identified for repair and elimination to prevent valve damage caused by using force to open and close the valve.