- Phone
-
Address
3rd Floor, Innovation Building, Jinshi Industrial Park, Xinshi North Road, Shijiazhuang City
Shijiazhuang Derun Environmental Protection Technology Co., Ltd
3rd Floor, Innovation Building, Jinshi Industrial Park, Xinshi North Road, Shijiazhuang City
Application Overview:
This sampler is mainly used in automatic monitoring systems for surface water quality in river sections and drinking water sources. Acceptable on-site industrial computer control, integrated with various online monitoring devices to coordinate work. When there is a need for abnormal detection or special sample retention, automatic sample retention, automatic emptying of water samples, and automatic sealing of bottle mouths can be achieved. It is a component of the automatic water quality monitoring system.
Features:
Conventional sampling: timed, time proportional, excessive retention, synchronous retention, external control sampling;
Bottle division method: single bottle, double bottle, and equal bottle division method;
Synchronize sample retention:Synchronize sampling and retention with online monitoring devices for data comparison;
Automatic emptying: can automatically empty the sample bottle water sample;
Remote control: can realize remote status query and parameterNumerical settings, remote sampling, etc;
Automatic sealing: The cap of the sample bottle can be automatically sealed;
Records: with alarm records, sample retention records, door opening and closing records, and power outage records;
Sample retention failure alarm: When water sample collection fails, the sample retention failure alarm record is automatically saved;
Access control system: electronic lock password unlocking, automatic recording of opening and closing of sample box doors;
Power outage protection: automatic protection upon power outage, automatic restoration upon power on;
Low temperature refrigeration: Compressor refrigeration, set at any temperature between 0-20 ° C.
Technical Indicators:
|
Sampling bottle |
Specification: Glass bottle 1000ml x 12 bottles |
|
Single sampling quantity |
10ml~1000ml |
|
sampling interval |
1min~9999min |
|
Sampling quantity error |
±7% |
|
Proportional sampling error |
±8% |
|
System clock time control error |
Δ1≤0.1% Δ12≤30s |
|
temperature control accuracy |
±2℃ |
|
Sampling vertical height |
≥8m |
|
Horizontal sampling distance |
≥80m |
|
Airtightness of pipeline system |
≤-0.085MPa |
|
Mean Time Between Failures (MTBF) |
≥ 1440 h/time |
|
insulation resistance |
>20 MΩ |
|
communication interface |
RS-232/RS-485 |
|
mock interface |
(4~20)mA |
|
Digital input interface |
discrete signal |