Dehumidifier detectionImportance of:
As an important device for regulating indoor humidity, it is widely used in households, industries, warehouses, and commercial places. Its performance is directly related to the improvement of air quality, moisture protection of items, and human comfort. With the rapid development of the dehumidifier market, there are a wide variety of products with uneven quality. Therefore, it is particularly important to conduct scientific and standardized testing on dehumidifiers. Through testing, it can be ensured that the product meets safety, energy efficiency, and performance requirements, avoiding safety hazards caused by design defects or manufacturing issues, while improving user experience and energy efficiency.
Testing items and scope
Dehumidifier detectionUsually covering multiple key projects, mainly including:
1. Safety performance testing: involving electrical safety, insulation resistance, grounding continuity, mechanical strength, etc., to ensure that the equipment will not cause harm to users or the environment under normal use and abnormal conditions.
2. Performance parameter testing: including core indicators such as dehumidification capacity, dehumidification capacity per unit input power, noise level, air flow rate, etc., to evaluate the dehumidification effect and energy efficiency performance of the product under actual working conditions.
3. Environmental adaptability testing: Test the operational stability of the equipment under different temperature and humidity conditions, such as high temperature and high humidity, low temperature and low humidity, etc.
4. Durability and reliability testing: Verify the product's service life and failure rate through long-term continuous operation or accelerated aging tests.
5. Material and structural testing: Check the corrosion resistance, fire rating, and structural rationality of the shell material, internal components, and connecting parts.
Dehumidifier detectionThe testing standards
| Dehumidifier testing items | |
| testing indicators |
Testing Standard |
| Dehumidification capacity, unit input power dehumidification capacity, noise, high load operation experiment, condensation experiment, low temperature operation experiment, power, operation |
GB/T 19411-2003 |
| Electrical safety |
GB 4706.32-2012 |