E-mail
milwaukee@126.com
-
Phone
18514045185
-
Address
2305, 20th Floor, Unit 5, Building 3, No. 6 Liqing Road, Chaoyang District, Beijing
Miwoqi Technology (Beijing) Co., Ltd
milwaukee@126.com
18514045185
2305, 20th Floor, Unit 5, Building 3, No. 6 Liqing Road, Chaoyang District, Beijing
Thermo Scientific™ Orion Lab StarSeries desktop water quality analyzer
Simplify your laboratory water quality testing work, be agile and efficient, and choose with peace of mind

Explore the new generation Orion measuring instrument
利用 Thermo Scientic ™ Orion ™ The Lab Star series measuring instrument is used for routine pH, conductivity, and dissolved oxygen testing. The detection adopts a large-sized backlit display screen, allowing you to easily and conveniently read and record sample measurement values. This measuring instrument is compact in size, which helps reduce the space occupied by its experimental table
self1962 Since the beginning of the year
Thermo Scientific ™ Orion ™ The product has established quality standards for analysis, testing, and measurement.
Orion lab products can help scientists solve some of the challenging problems facing today's society. Whether used to provide safe drinking water to communities, test food or control the quality and safety of products, or discover new drug therapies, Orion products can provide precise and accurate readings on-site and in the laboratory.
The Thermo Scientific Orion Lab Star desktop measuring instrument is suitable for academic, water, wastewater, and other laboratories that pursue lightweight and easy to operate electrochemical detection instruments. If the Orion Lab Star measuring instrument is used in combination with Thermo Scientific Orion electrodes and solutions, it can also achieve cost-effective pH, conductivity, and dissolved oxygen parameter detection and measurement.

Orion Lab Star D0113 Desktop Dissolved Oxygenmeasuring instrument
Complete your dissolved oxygen measurement
Simultaneously read the saturation or concentration percentage of dissolved oxygen and temperature
Measure saturation from 0.0 to 300.0%, 0.00 to 30.0 mg/L or ppm, and -5.0 to+105.0 ℃ (+23.0 to+221.0 ℉)
• Use custom values (Winkler) for 100% and 0% saturation calibration or one point concentration calibration
• Use automatic pressure compensation for DO measurement, manually input values in mmHg or bar
• Use automatic salinity compensation for DO measurement, manually input values from 0.0 to 50.0 ppt
Review dissolved oxygen and temperature calibration logs with date and timestamp
Product Specifications |
Orion Lab Star DO113Dissolved oxygen measuring instrument |
|
dissolved oxygen |
Range, saturation percentage |
0.0 to300.0% saturation |
Resolution, saturation percentage |
0.1, 1% saturation |
|
Relative accuracy, saturation percentage |
saturation ±1 LSD |
|
Range, concentration |
0.00 to 30.0 mg/L or ppm |
|
Resolution, concentration |
0.01, 0.1 mg/L or ppm |
|
Relative accuracy, concentration |
± 0.2 mg/L or ppm ± 1 LSD |
|
Calibration Type |
100% and 0% saturation; Custom concentration value |
|
Pressure compensation |
400.0 to 850.0 mmHg; 0.533 to 1.133 bar |
|
Salinity compensation |
0.0 to 50.0 ppt |
|
|
temperature
|
range |
-5.0 to+105.0 ℃ (+23.0 to+221.0 ℉) |
resolution |
0.1℃; 0.1℉ |
|
Relative accuracy |
±0.3℃,±0.5℉ |
|
input |
Manual or automatic, with built-inATC |
|
calibration point |
1 point, ± 5 ℃ |
|
Measurement instrument function |
display |
5-inch backlit LCD display screen |
date and time |
yes |
|
Read type |
Continuous, automatic reading, timed |
|
data log |
500 sets, with time and date |
|
Calibration log |
Dissolved oxygen and temperature, with time and date |
|
data output |
Computer or printer |
|
Calibration expiration alert |
1-168 hours or off |
|
alarm |
Light alarm and activation/Turn off the sound alarm |
|
存储器 |
non-volatile |
|
warranty period |
3 years |
Orion Lab Star DO113 Desktop Dissolved Oxygen Meter Model
Connect the measuring instrument and bench with your ownPair the DO probe with the solution, or choose a pre configured kit to get everything you need.
description |
Item Number |
|
Orion Lab Star DO113 desktop dissolved oxygen analyzer, including: • Measuring instrument with stand Computer cables 100 to 240 V, 50/60 Hz universal power adapter with twist lock connector |
LSTAR1130 |
|
Orion Lab Star DO113 Desktop Dissolved Oxygen Meter Standard Kit, including • Measuring instrument with stand, computer cable, and universal power adapter Polarographic DO/ATC probe with calibration sleeve (item number: 083005MD) • DO probe maintenance kit (item number: 080513) BOD adapter (item number: 080360) |
LSTAR1135 |
Orion dissolved oxygen probe and solution
description |
DOscope |
temperature range |
Relative accuracy |
temperature sensor |
Minimum sample flow rate |
Size (length)X width) |
cable |
Item Number |
Universal polarography DO/ATC probe |
0 to 200% saturation; 0 to 20 mg/L |
0 to 50 ℃ |
± 2% DO reading; ±2℃ |
Duo He Yi, Dual Source |
10 cm/sec |
120×15 mm |
1.5 m,MiniDIN |
083005MD |
polarography DO/ATC probe, long cable |
0 to 200% saturation; 0 to 20 mg/L |
0 to 50 ℃ |
± 2% DO reading; ±2℃ |
Duo He Yi, Dual Source |
10 cm/sec |
120×15 mm |
3 m,MiniDIN |
083010MD |
polarography DO/ATC probe, basic use |
0 to 200% saturation; 0 to 20 mg/L |
0 to 50 ℃ |
± 2% DO reading; ±2℃ |
Multi in one, single source |
20 cm/sec |
120×13 mm |
3 m,MiniDIN |
081010MD |
description |
Item Number |
Maintenance kit, including electrolyte, polishing disc, and 2 Probe film cap (item number:083005MD and 083010MD) |
080513 |
Maintenance kit, including electrolyte, polishing disc, and2 probe caps (item number: 081010MD) |
080113 |
1 probe cap (item numbers: 083005MD and 083010MD) |
080515 |
3 probe caps (item number: 081010MD) |
081003 |
Probe polarographic electrolyte (item number:083005MD, 083010MD, and 081010MD) |
080514 |
probeBOD adapter (item numbers: 083005MD and 083010MD) |
080360 |
probeBOD adapter (item number: 081010MD) |
080160 |
Orion Lab Star series desktop measuring instrument accessories
Choosing the right accessories can help you achieve a more efficient workflow every time.
|
description
|
purpose
|
Compatible item number
|
Item Number
|
Orion Lab Star series measuring instrument comes with a stand |
Replace your stand as needed |
PH111,EC112,DO113 |
LSTAR-ARM |
Orion Lab Star series universal power supply, 100 to 240V, 50/60 Hz |
Replace your power adapter as needed |
PH111,EC112,DO113 |
LSTAR-PWR |
Orion Lab Star Series USB Computer Cable |
Replace your computer cable as needed |
PH111,EC112,DO113 |
LSTAR-USB |
Orion Lab Star series measuring instrument dust cover |
During storage, the dust cover can prevent dust and debris from entering the measuring instrument |
PH111,EC112,DO113 |
LSTAR-CVR |
Orion compact ink ribbon printer (with cable), 100 to 240V |
Print data from the measuring instrument to a file and keep records |
PH111,EC112,DO113 |
STARA-106 |
Orion Compact Printer Replacement Ink Ribbon, 6 Pack |
Replace your ink ribbon as needed |
STARA-106 printer |
STARA-108 |
Orion Compact Printer Replacement Paper, 5 packs |
Replace your printer paper as needed |
STARA-106 printer |
STARA-109 |
forConductivity Calibration Resistors Kit for Orion Lab Star EC112 Conductivity Meter |
Check the functionality of the conductivity meter independent of the conductivity probe |
EC112 |
1010001 |