1、 Product Introduction: The EXPEC 3200 Portable Non Methane Total Hydrocarbon Analyzer (expandable for measuring non methane total hydrocarbons+benzene derivatives) is a truly portable product designed to meet the needs of field applications. One chassis integrates all modules for non methane total hydrocarbon detection, including valves, chromatography columns FID、 Carrier gas cylinders, air cylinders, standard gas cylinders, batteries, and sampling probes can directly measure non methane total hydrocarbons and benzene derivatives without the need to connect to the mains or gas pipelines on site, and output reports. The product is equipped with a sampling pump and a quantitative loop to achieve accurate quantification. It uses chromatographic separation and hydrogen flame ionization detector (FID) for analysis, and can simultaneously measure the total hydrocarbon and methane content in fixed pollution source exhaust gas and unorganized air at the factory boundary. The non methane total hydrocarbon content is automatically calculated, fully meeting the requirements of HJ38-2017 and HJ1012-2018 standards. The product uses a quantitative loop to introduce a fixed volume of samples into the total hydrocarbon column and methane separation module, respectively, to obtain the concentrations of total hydrocarbons and methane. The concentration of non methane total hydrocarbons is obtained by subtracting the concentration of methane from the total hydrocarbons. The product is widely used for on-site determination of methane and non methane total hydrocarbons from fixed pollution sources, monitoring of methane and non methane total hydrocarbons in atmospheric environments, emission detection of automobile exhaust, emission detection of combustion devices, gas detection in paint spraying workshops, etc. 2、 Product parameters
Product Details
  • 1、 Product Introduction

    EXPEC 3200Portable non methane total hydrocarbon analyzer (expandable for measuring non methane total hydrocarbons)+Benzene series compounds are a truly portable product designed with the needs of on-site applications in mind. One chassis integrates all modules for non methane total hydrocarbon detection, including valves, chromatography columnsFIDThe carrier gas cylinder, air cylinder, standard gas cylinder, battery, and sampling probe can directly measure non methane total hydrocarbons and benzene derivatives without the need to connect the mains power and gas pipelines on site, and output reports.

    The product is equipped with a built-in sampling pump and a quantitative ring to achieve accurate quantification, using chromatographic separation and hydrogen flame ionization detector(FID)By conducting analysis, it is possible to simultaneously measure the total hydrocarbon and methane content in fixed pollution source exhaust gas and unorganized air at the factory boundary, and automatically calculate the non methane total hydrocarbon content, fully meeting the requirementsHJ38-2017andHJ1012-2018Standard requirements. The product uses a quantitative loop to introduce a fixed volume of samples into the total hydrocarbon column and methane separation module, respectively, to obtain the concentrations of total hydrocarbons and methane. The concentration of non methane total hydrocarbons is obtained by subtracting the concentration of methane from the total hydrocarbons.

    The product is widely used for on-site determination of methane and non methane total hydrocarbons from fixed pollution sources, monitoring of methane and non methane total hydrocarbons in atmospheric environments, emission detection of automobile exhaust, emission detection of combustion devices, gas detection in paint spraying workshops, etc.

    2、 Product parameters

    project

    index

    Monitoring capability

    total hydrocarbonmethaneNon methane total hydrocarbonsScalableMulti factor detection of benzene derivatives and other compounds

    detector

    FIDdetector

    Injection method

    Quantitative Loop Quantification

    detection limit

    0.1ppm

    repeatability

    RSD2%

    measuring range

    0.1~30000ppm(Customizable)

    Analysis cycle

    2min

    data analysis

    Internal flash memory, continuous measurement, capable of storing data information for at least six months

    work environment

    Temperature:-5~45℃; Humidity:0~95%RH

    Gas supply method

    Hydrogen gas:75mlHigh pressure gas cylinder, can be repeatedly filled and released;Optional hydrogen storage alloy

    Carrier gas:75mlHigh pressure gas cylinder, can be repeatedly filled and released

    Standard gas:75mlHigh pressure gas cylinder, can be repeatedly filled and released

    Power supply mode

    Battery powered: capable of running the instrument4More than hours

    Municipal power supply: can provide long-term continuous operation of instruments

    data output

    WIFIEthernet, etc


    3、 Product Features

    1.High integration: Integrate the conventional methane non methane total hydrocarbon online monitoring system into the same portable chassis, including display module, total hydrocarbon testing module, methane testing moduleFIDDetectors, batteries, hydrogen cylinders, zero gas cylinders, and standard gas cylinders free customers from the need to search for various standard gases, pipelines, and electrical connections, and focus on testing itself.

    2.Supporting the expansion of testing institutions and providing original spectra: the instrument has passed the national standardsCPACertification, supports exporting original test data and original test spectra for third-party testing agencies to issue reports containing original spectraCMAreport

    3.No need for mains power, longer battery life and safer: Equipped with a super large capacity battery, it can simultaneously supply power to both the host and the heat tracing pipeline for at least operation4hYou don't need to answer on site220VElectricity is safer and more efficient to use.

    4. High on-site detection efficiency: instant testing, supporting multi-point transfer of thermal engines on-site, with ultra-high on-site detection efficiency; High integration, on-site multi-point transfer without the need for repeated disassembly and installation.

    5.Full process high-temperature heat tracing: from sampling toFIDThe detector achieves high accuracy throughout the entire process180High temperature heat tracing at ℃ effectively solves the problem of condensation loss of samples in high-temperature and high humidity gas environments, providing accurate test results.

    6.Fully automatic determination of methane and non methane total hydrocarbons: full flow pathEPC(Electronic pressure control) design, dual quantitative loop quantification, dual channel analysis, automatic measurement of total hydrocarbons, methane, and non methane total hydrocarbons with one-time injection, without the need for manual intervention.

    7.Specially designed probes for on-site portable testing:120High temperature tracing and inert material pipelines above ℃ ensure that sample contact will not cause any pollution or adsorption. They are compact in size, easy to carry, and have multiple specifications to choose from.

    8. Can store multiple calibration curves: The instrument is equipped with multiple calibration curves at the factory, allowing for quick selection of calibration curves suitable for different sample concentration conditions and accurate data measurement.

    9. Friendly human-computer interaction interface: The host adopts a color touch screen with a fully Chinese interface, large font text display, adjustable screen backlight, etc., which is convenient for customers to use on site. It can be equipped with a thermal printer and supports on-site detection data printing.

    10.Industry's first mobile handheld terminal: equipped with the industry's first mobile handheld terminal, customers can use it under harsh working conditionsAPPSoftware orsurfaceTablet software enables instrument operation, parameter setting, test result viewing, and data export, with simple and convenient operation, suitable for industrial useWIFIConnection is achievable10Remote control from a distance of meters.

    11.Low consumption of consumables and low maintenance costs: equipped with high-pressure gas cylinders that can be refilled and released with standard gas, carrier gas, and hydrogen gas; Activated carbon purification pipe andFIDThe ignition wire and other components have a long service life and can be replaced separately. Hydrogen can be optionally equipped with hydrogen storage alloys.