E-mail
njkhyq@126.com
-
Phone
13338629558
-
Address
Nanjing Jiangning University City Entrepreneurship Park
Nanjing Kehuan Analytical Instrument Co., Ltd
njkhyq@126.com
13338629558
Nanjing Jiangning University City Entrepreneurship Park
HCA--100Type standardCODThe digester is heated by a specially designed electric heating plate, with a microcrystalline glass tabletop and an overall structure,Reasonable isolation design, the microcrystalline heating plate is a single piece, and the installation and replacement of the electric furnace plate are very convenient and simple,When heating, the surface of the electric furnace plate heats up evenly, and the heating and cooling rates are fast. The sample solution accidentally drips onto it, making cleaning very convenient.
HCA--100Type standardCODThe digestion device can set the digestion time and display a countdown to the digestion time. After digestion is complete, the instrument automatically stops heating and the dual fans continue to work. It can assist in sample cooling and is unattended.
HCA--100Type standardCODDissolver, using glass burr reflux tube instead of spherical reflux tube, and air-cooled and water-cooledTechnology replaces circulating water cooling methods, making operation more convenient. The cooling part is mainly completed by burr condensation tube water cooling and fan air cooling, and the upper part of the condensation tube is spherical3Bubble to ensure cooling effect, catalyst is added from here to prevent the instantaneous volatilization of light components in the sample, and a volatilization cap can be added. The following section is'burr'Shape, protruding from the wall of a condenser tube on a plane3A person facing each other'Cold Bubble'Compared to a simple spherical condenser tube, it increases the cooling area and can block the passage of volatile substances and vapors. In addition, the cooling water in the upper part of the spherical reflux tube and the fan inside the machine have a dual effect,standardCODDigestion device,Ensure the reflux cooling of the sample,Insert type burr reflux tube, safe and stable to use.
Technical specifications:
Compliant with national standard: New standardHJ828-2017Replace the originalGB 11914-89
Measurement range:5~700mg/L;700mg/L~10000 mg/LDetermination after dilution of water sample
Dissolving time:1Minutes~2hour30Minutes (Users can choose their own heating time)
Measurement error: Potassium hydrogen phthalate standard solution(500mg/L)The relative standard deviation is not greater than5%;
Industrial organic wastewater(500mg/L)The relative standard deviation is not greater than8%
Environmental temperature: ≤ 40℃
Cooling method: upper insertion type3Bubble burr condensation tube water cooling and dual fan dual cooling are completed. Fan air cooling can be manually or automatically controlled.
Number of Dissolved Samples:8a250mlCone shaped bottle,Simultaneously heat and digest in two rows
Heating power: <1600W(AC 220V,50HZ)
Heating table:Microcrystalline glass heating table top, overall structure of heating plate, overhead heating, easy to replace and maintain by removing directly.
Instrument size:490*290*605mm(H)