Explosion proof control box BZC8060-A2D2K1L explosion-proof operating column

NegotiableUpdate on 05/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The explosion-proof control box BZC8060-A2D2K1L explosion-proof operation column determines the installation position and method of the lamps according to the actual lighting needs of the work site, and then prepares three core cables of corresponding length according to the distance from the lamps to the 220V power supply contact (if steel pipe wiring is used, the three core cables are led into the steel pipe to the lamp installation location).

Product Details

Explosion proof control box BZC8060-A2D2K1LExplosion-proof operation column


1.Execution standard:GB 3836.1TheGB 3836.2TheGB 3836.3TheGB 12476.1TheIEC 60079

2.Explosion proof mark:ExdeBT6TheDIP A20 TAT6 3.Rated voltageAC 220V/380V

4.Rated current of main circuit:20A250A

5.Number of branches:24681012

6.Rated current of branch:1AThe3AThe5AThe10AThe15AThe20AThe25AThe32AThe40AThe50AThe60A

7.Protection level:IP54(ⅡB)TheIP55DIP)TheIP65(with rain cover)

8.Anti corrosion grade:WF1

9.Entrance specifications:G1/2G3'

10.Applicable cable outer diameter: Φ6~Φ55mm

11.Inlet direction: bottom in and bottom out, bottom in and top out, top in and top out, or top in and bottom out

Instructions for use

1According to the actual lighting needs of the work site,Determine the installation location and method of the lighting fixtures,Then press the light fixture to220VPrepare a corresponding length of three core cable for the distance of the power contact (if steel pipe wiring is used, introduce the three core cable into the steel pipe to the installation location of the lamp).

2First, remove the fixing screws on the wiring cavity,Pull out the wiring part of the junction box;Remove the sealing ring and connector (with set screws) from the packaging box,Insert the cables in sequence;Then connect one end of the three core cable to the label inside the box“L”The“N”And the grounding point,After tightening the cable with a crimping card,And fix it with fastening screws,Then tighten the joint,Tighten the sealing ring,And tighten the set screw from the side.

3, will be2The components of the step are screwed into the steel pipe,Install the fastening screw from the side to lock it in place,Then install the lamp body along the guide rail of the junction box,Then tighten the screws on the panel.

4Finally, connect the other end of the three core cable according to the requirements of the explosion-proof distribution box220VPower Supply.

5When replacing the light bulb,Cut off the power first,Then use an Allen wrench to remove the set screws from the housing,Use a large screwdriver or other tool to loosen the lamp cover6circle,Carefully remove the lamp cover with your hands,Unscrew the old light bulb and replace it with a new one.

Ordering Notice:Explosion proof control box BZC8060-A2D2K1LExplosion-proof operation column

When placing an order, the number of branches of the distribution box, the corresponding current of each branch, and the number of poles of the circuit breaker should be specified. If leakage protection function is required, please indicate it;

If a main switch is required, please indicate the number of poles used for the main switch's current, as well as the direction of the incoming and outgoing lines, the specifications of the incoming and outgoing lines, and the corresponding quantity;

Explosion proof lighting (power) distribution box, can be specially designed according to user requirements, and users need to provide electrical system diagrams;

The shipping cost can be agreed upon by both parties.