Welcome Customer !

Membership

Help

Zhejiang Yamin Explosion proof Technology Co., Ltd
Custom manufacturer

Main Products:

cep-online>Products

Explosion proof distribution box, instrument box, control box, distribution cabinet, switch junction box

NegotiableUpdate on 05/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Working principle of explosion-proof dual power automatic conversion control box: If the external power supply is actually cut off during operation and use, the backup controller in the explosion-proof dual power automatic conversion control box will instantly start the power switching device. The explosion-proof dual power conversion control box has two functions: manual and automatic switching. The panel of the box is fixed with screws around it, which is not only beautiful but also easy to disassemble. During maintenance, simply remove the screws. Explosion proof distribution box, instrument box, control box, distribution cabinet, switch and junction box

Product Details

Explosion proof distribution box, instrument box, control box, distribution cabinet, switch junction box


One control, one explosion-proof sewage pump control boxSuitable for various technical specifications of submersible sewage systems, design and produce low-voltage electrical appliances and sensor controllers with high durability according to relevant standards and industry standards. The one control one sewage pump control cabinet is particularly suitable for automatic control and protection in industrial and mining enterprises such as hotels, construction, metallurgy, chemical industry, mining, petroleum, textile, as well as underground engineering, municipal engineering, sewage treatment and other departments.

Characteristics of Control Cabinet for Control One Sewage Pump:

The selection of branded low-voltage electrical circuits is reasonable and concise, with durable control programs, resulting in excellent system performance, flexible control, and resistance to damageInterference energyStrong strength and durable work.

Explosion proof distribution box, instrument box, control box, distribution cabinet, switch junction box



It has protection functions such as motor overload, short circuit, phase loss, pump leakage, and high temperature of motor stator, making it easy to use and maintain.

Set up manual and automatic control functions to ensure continuous operation of equipment protection.

Programmable control, capable of achieving single level control, multi level control, automatic alternating operation of main and backup pumps, automatic timed rotation, pressure control, etc. according to user needs

Configurable touch operation human-machine interface product, high-power water pump can use frequency converter or intelligent soft start to achieve smooth start.

Working principle of one control and one sewage pump control cabinet:

1.Control the discharge float of ordinary sewage pits

The system can use one or more water pumps. When using a water pump, the float switch fluctuates up and down with the liquid level in the sewage pit. When the float is at the pump water level, it starts the submersible pump through the control cabinet to start draining water; When the float is at the stop pump water level, the float stops the operation of the submersible pump through the control cabinet. When multiple pumps are used, the backup pump automatically starts running and the control cabinet displays a fault signal for the submersible pump.

Liquid level standby pump put into operation: When the main pump flows into the collection pit with low sewage flow, high flow or main pump failure causes the liquid level to rise to another float switch, the standby pump is also put into operation.

2.Discharge control of drainage pump station

manual replacement/Fault switching: Choose either the main pump or the backup pump. When the main pump is working at high water level, if the main pump fails or the control circuit fails, each pump will be delayed and sound and light alarms will be issued. When the sewage flow into the collection pit exceeds the discharge capacity of the main pump, the standby pump is delayed and emits an audible and visual alarm

3.Discharge control of drainage pump station

Automatic alternating rotation: When the water level reaches a high level1start#(or2#After the drainage is completed, when the water level reaches the high water level for the second time, the wheel is2#(or1#When the water level of the pump reaches the high water level, both pumps are put into operation to complete the drainage and rotation of the main and backup pumps.

Explosion proof electric heat tracing control box-Electric heat tracing explosion-proof box

Scope of application of explosion-proof control box

1Suitable for explosive gas environments1District2Dangerous areas in the district;

2. Applicable toIIATheIIBTheIICExplosive gas environment;

3Suitable for environments with combustible dust20District21District22District;

4Suitable for temperature groups ofT1—T6The environment;

5Suitable for explosive hazardous environments such as petroleum and petrochemical, chemical, brewing, pharmaceutical, paint, textile, printing and dyeing, facilities, etc;

Explosion proof control box Explosion proof control box

1 The shell of this product is made of high-quality steel plates welded together, and the surface is subjected to high-speed shot blasting followed by powder electrostatic spraying, resulting in a beautiful appearance;

2This product isBenjamin Explosion proofImproved explosion-proof product, which can be equipped with explosion-proof buttons, explosion-proof indicator lights, explosion-proof ammeters, explosion-proof switches, explosion-proof voltmeters and other instruments and control components inside;

3Adopting diverse designs, one can choose from cabinet style (top and bottom, left and right), wall mounted, piano table style, flat style, etc;

4Protective doors can be installed according to customer requirements, which can display the display or action of internal control parts;

5All fasteners are made of corrosion-resistant materials304Stainless steel material;

6 Wiring methods include steel pipes, cables, and explosion-proof hoses;

7 Customized according to user requirements;

Technical parameters of explosion-proof control box

1Explosion proof mark:ExdeIIBT4/T5/T6TheExdeIICT4/T5/T6TheDIP A20 TA,T4/T5/T6

2Rated voltage:AC220/380V,Non standard voltage:12V/24V/36V/127V/660V

3Main switch current:10A—800ASwitching current:1A—630A

4Protection level:IP54/IP55/IP65

5Thread specifications:DN15-DN100/G1/2-G4inch

6Introduction line specification: diameter6mm-80mmLead out specifications: diameter6mm-80mm

7Introduction and exit directions: upward and upward, downward and downward (unrestricted according to customer requirements)

Kind Reminder
Our company's products have been inspected and qualified by formal inspection agencies. Please do not question the quality of the products.
Please strictly follow the product manual for installation and have professional electricians perform installation and debugging.

After sales service: Within one year from the date of purchase, our company is responsible for repairing any product quality problems that occur naturally.