Welcome Customer !

Membership

Help

Zhejiang Zhechuang Explosion proof Electrical Co., Ltd
Custom manufacturer

Main Products:

cep-online>Products

Explosion proof instrument box

NegotiableUpdate on 03/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Product features of explosion-proof key instrument box in steel plant: 1. Aluminum alloy die-casting molding, surface polishing treatment, beautiful and bright appearance; 2. It has good dust and water discharge performance, and the protection level can reach IP65 or above; 3. The external structure can be customized according to user requirements; 4. Equipped with explosion-proof Ex components such as switches, buttons, indicator lights, and instruments.
Product Details
Scope of application:Explosion proof key instrument box in steel plant96 * 96 electric heat tracing explosion-proof instrument control box
1. Suitable for hazardous areas in Zone 1, Zone 2, Zone 21, and Zone 22;
2. Suitable for IIA, IIB, IIC level explosive gas environments or combustible dust environments;
3. Indoor and outdoor (IP65 stainless steel explosion-proof instrument box)
Product Features:
1. Aluminum alloy die-casting molding, surface polishing treatment, beautiful and bright appearance;
2. It has good dust and water discharge performance, and the protection level can reach IP65 or above;
3. The external structure can be customized according to user requirements;
4. Equipped with explosion-proof Ex components such as switches, buttons, indicator lights, and instruments.
5. Both hanging and standing styles are acceptable
6. Steel pipe or cable wiring
Technical Specifications:Explosion proof key instrument box in steel plant96 * 96 electric heat tracing explosion-proof instrument control box
1. Rated voltage: 220/380V
2. Rated current: 6A, 10A, 16A
3. Usage category: AC-3 AC-4
4. Explosion proof signs: Exd IICT6, Exd IIBT6
5. Anti corrosion grade: WF1
6. Protection level: IP65/IP54
Installation and maintenance:
Before installation and maintenance, it is necessary to cut off the front-end power supply;
4.2 The incoming and outgoing cables should pass through rubber sealing rings and be tightly sealed with gaskets and clamping devices to prevent the cables from loosening;
4.3 During maintenance and disassembly, be careful not to bump or scratch the explosion-proof surface, and apply 204-1 anti rust oil;
4.4 The instrument box should be regularly inspected during use to ensure its sealing performance and good operation;
4.5 Grounding must be good and reliable;
4.6 Non professionals are strictly prohibited from opening the cover for installation and maintenance.
4.7 Wiring method