Phone
18968989982
-
Address
Modao Industrial Zone, Oubei Town, Yongjia, Wenzhou, Zhejiang Province
Yongjia Quanda Pump and Valve Manufacturing Co., Ltd
18968989982
Modao Industrial Zone, Oubei Town, Yongjia, Wenzhou, Zhejiang Province
YG explosion-proof pipeline oil pumpThe import and export flanges are on the same centerlineISG pipeline pumpThe extended product can be directly installed on the pipeline, with a vertical structure and integrated pump, occupying a small area and making installation very convenient. YG type explosion-proof pipelineoil pumpAdopting high-quality mechanical seals, there is no leakage, effectively reducing the oil and gas content in the pump room, improving the working environment, and enhancing the safety and reliability of the pump room operation.
YG explosion-proof pipeline oil pumpWhere are the advantages?
1. YG explosion-proof pipeline oil pump can operate outdoors without building a pump room.|
|
1 |
Pressure plug |
|
2 |
exhaust valve |
|
|
3 |
impeller |
|
|
4 |
mechanical seal |
|
|
5 |
bearing |
|
|
6 |
electrical machinery |
|
|
7 |
Joint venture |
|
|
8 |
water deflector |
|
|
9 |
IMPELLER NUT |
|
|
10 |
pump body |
|
|
11 |
Drain valve |

YG explosion-proof pipeline oil pumpSelection parameters
|
caliber |
flowmeasure |
lift |
efficiency |
rotational speed |
Motor Power |
Required cavitation allowance |
||
|
mm |
m3/h |
L/S |
m |
% |
r/min |
KW |
(NPSH)r |
|
|
15-80 |
15 |
1.1 |
0.3 |
8.5 |
26 |
2800 |
0.18 |
2.3 |
|
20-110 |
20 |
1.8 |
0.5 |
16 |
25 |
2800 |
0.37 |
2.3 |
|
20-160 |
20 |
1.8 |
0.5 |
33 |
19 |
2900 |
0.75 |
2.3 |
|
25-110 |
25 |
2.8 |
0.78 |
16 |
34 |
2900 |
0.55 |
2.3 |
|
25-125 |
25 |
2.8 |
0.78 |
20.6 |
28 |
2900 |
0.75 |
2.3 |
|
25-125A |
25 |
2.5 |
0.69 |
17 |
35 |
2900 |
0.55 |
2.3 |
|
25-160 |
25 |
2.8 |
0.78 |
33 |
24 |
2900 |
1.5 |
2.3 |
|
25-160A |
25 |
2.6 |
0.12 |
29 |
31 |
2900 |
1.1 |
2.3 |
|
model |
caliber |
internet traffic |
lift |
efficiency |
rotational speed |
Motor Power |
Required cavitation allowance |
|
|
mm |
m3/h |
L/S |
m |
% |
r/min |
KW |
(NPSH)r |
|
|
32-100(I) |
32 |
4.4 |
1.22 |
13.2 |
48 |
2900 |
0.75 |
2.0 |
|
32-125 |
32 |
3.5 |
0.97 |
22 |
40 |
2900 |
0.75 |
2.3 |
|
32-125A |
32 |
3.1 |
0.86 |
17.6 |
43 |
2900 |
0.55 |
2.3 |
|
32-160(I) |
32 |
4.4 |
1.22 |
33.2 |
34 |
2900 |
2.2 |
2.0 |
|
32-200(I) |
32 |
4.4 |
1.22 |
50.5 |
26 |
2900 |
4 |
2.0 |
|
32-200A |
32 |
2.8 |
0.78 |
44.6 |
34 |
2900 |
2.2 |
2.0 |
|
model |
caliber |
internet traffic |
lift |
efficiency |
rotational speed |
Motor Power |
Required cavitation allowance |
|
|
mm |
m3/h |
L/S |
m |
% |
r/min |
KW |
(NPSH)r |
|
|
40-100 |
40 |
4.4 |
1.22 |
13.2 |
48 |
2900 |
0.55 |
2.3 |
|
40-100A |
40 |
3.9 |
1.08 |
10.6 |
52 |
2900 |
0.37 |
2.3 |
|
40-125 |
40 |
4.4 |
1.22 |
21 |
41 |
2900 |
1.1 |
2.3 |
|
40-125A |
40 |
3.9 |
1.08 |
17.6 |
40 |
2900 |
0.75 |
2.3 |
|
40-160 |
40 |
4.4 |
1.22 |
33 |
35 |
2900 |
2.2 |
2.3 |
|
40-160A |
40 |
4.1 |
1.14 |
29 |
34 |
2900 |
1.5 |
2.3 |
|
40-160B |
40 |
3.8 |
1.06 |
25.5 |
34 |
2900 |
1.1 |
2.3 |
|
40-200 |
40 |
4.4 |
1.22 |
51 |
26 |
2900 |
4 |
2.3 |
|
40-200A |
40 |
4.1 |
1.14 |
45 |
26 |
2900 |
3 |
2.3 |
|
40-200B |
40 |
3.7 |
1.03 |
38 |
29 |
2900 |
2.2 |
2.3 |
|
40-250 |
40 |
4.4 |
1.22 |
82 |
24 |
2900 |
7.5 |
2.3 |
|
40-250A |
40 |
4.1 |
1.14 |
72 |
24 |
2900 |
5.5 |
2.3 |
|
40-250B |
40 |
3.8 |
1.06 |
61.5 |
23 |
2900 |
4 |
2.3 |
|
model |
caliber |
internet traffic |
lift |
efficiency |
rotational speed |
Motor Power |
Required cavitation allowance |
|
|
mm |
m3/h |
L/S |
m |
% |
r/min |
KW |
(NPSH)r |
|
|
40-100(I) |
40 |
8.8 |
2.44 |
13.2 |
55 |
2900 |
1.1 |
2.3 |
|
40-100(I)A |
40 |
8 |
2.22 |
10.6 |
60 |
2900 |
0.75 |
2.3 |
|
40-125(I) |
40 |
8.8 |
2.44 |
21.2 |
49 |
2900 |
1.5 |
2.3 |
|
40-125(I)A |
40 |
8 |
2.22 |
17 |
57 |
2900 |
1.1 |
2.3 |
|
40-160(I) |
40 |
8.8 |
2.44 |
33 |
45 |
2900 |
3 |
2.3 |
|
40-160(I)A |
40 |
8.2 |
2.28 |
29 |
44 |
2900 |
2.2 |
2.3 |
|
40-160(I)B |
40 |
7.3 |
2.38 |
23 |
50 |
2900 |
1.5 |
2.3 |
|
40-200(I) |
40 |
8.8 |
2.44 |
51.2 |
38 |
2900 |
5.5 |
2.3 |
|
40-200(I)A |
40 |
8.3 |
2.31 |
45.0 |
37 |
2900 |
4 |
2.3 |
|
40-200(I)B |
40 |
7.5 |
2.08 |
37 |
44 |
2900 |
3 |
2.3 |
|
40-250(I) |
40 |
8.8 |
2.44 |
81.2 |
31 |
2900 |
11 |
2.3 |
|
40-250(I)A |
40 |
8.2 |
2.28 |
71.0 |
38 |
2900 |
7.5 |
2.3 |
|
40-250(I)B |
40 |
7.6 |
2.11 |
61.4 |
37 |
2900 |
7.5 |
2.3 |
|
40-250(I)C |
40 |
7.1 |
1.97 |
53.2 |
36 |
2900 |
5.5 |
2.3 |
|
model |
caliber |
internet traffic |
lift |
efficiency |
rotational speed |
Motor Power |
Required cavitation allowance |
|
|
mm |
m3/h |
L/S |
m |
% |
r/min |
KW |
(NPSH)r |
|
|
50-100 |
50 |
8.8 |
2.44 |
13.6 |
55 |
2900 |
1.1 |
2.3 |
|
50-100A |
50 |
8 |
2.22 |
11 |
60 |
2900 |
0.75 |
2.3 |
|
50-125 |
50 |
8.8 |
2.44 |
21.5 |
49 |
2900 |
1.5 |
2.3 |
|
50-125A |
50 |
8 |
2.22 |
17 |
57 |
2900 |
1.1 |
2.3 |
|
50-160 |
50 |
8.8 |
2.44 |
33 |
45 |
2900 |
3 |
2.3 |
|
50-160A |
50 |
8.2 |
2.28 |
29 |
44 |
2900 |
2.2 |
2.3 |
|
50-160B |
50 |
7.3 |
2.38 |
23 |
50 |
2900 |
1.5 |
2.3 |
|
50-200 |
50 |
8.8 |
2.44 |
52 |
38 |
2900 |
5.5 |
2.3 |
|
50-200A |
50 |
8.3 |
2.31 |
45.8 |
37 |
2900 |
4 |
2.3 |
|
50-200B |
50 |
7.5 |
2.08 |
37 |
44 |
2900 |
3 |
2.3 |
|
50-250 |
50 |
8.8 |
2.44 |
82 |
29 |
2900 |
11 |
2.3 |
|
50-250A |
50 |
8.2 |
2.28 |
71.5 |
38 |
2900 |
7.5 |
2.3 |
|
50-250B |
50 |
7.6 |
2.11 |
61.4 |
37 |
2900 |
7.5 |
2.3 |
|
50-250C |
50 |
7.1 |
1.97 |
53.2 |
36 |
2900 |
5.5 |
2.3 |
|
model |
caliber |
internet traffic |
lift |
efficiency |
rotational speed |
Motor Power |
Required cavitation allowance |
|
|
mm |
m3/h |
L/S |
m |
% |
r/min |
KW |
(NPSH)r |
|
|
50-100(I) |
50 |
17.5 |
4.86 |
13.7 |
67 |
2900 |
1.5 |
2.5 |
|
50-100(I)A |
50 |
15.6 |
4.3 |
11 |
65 |
2900 |
1.1 |
2.5 |
|
50-125(I) |
50 |
17.5 |
4.86 |
21.5 |
60 |
2900 |
3 |
2.5 |
|
50-125(I)A |
50 |
15.6 |
4.33 |
17 |
58 |
2900 |
2.2 |
2.5 |
|
50-160(I) |
50 |
17.5 |
4.68 |
34.4 |
54 |
2900 |
4 |
2.5 |
|
50-160(I)A |
50 |
16.4 |
4.56 |
30 |
54 |
2900 |
4 |
2.5 |
|
50-160(I)B |
50 |
15.0 |
4.17 |
26 |
58 |
2900 |
3 |
2.5 |
|
50-200(I) |
50 |
17.5 |
4.86 |
52.7 |
49 |
2900 |
7.5 |
2.5 |
|
50-200(I)A |
50 |
16.4 |
4.56 |
46.4 |
48 |
2900 |
7.5 |
2.5 |
|
50-200(I)B |
50 |
15.2 |
4.22 |
40 |
55 |
2900 |
5.5 |
2.5 |
|
50-250(I) |
50 |
17.5 |
4.86 |
82 |
39 |
2900 |
15 |
2.5 |
|
50-250(I)A |
50 |
16.4 |
4.56 |
71.5 |
39 |
2900 |
11 |
2.5 |
|
50-250(I)B |
50 |
15 |
4.17 |
61 |
38 |
2900 |
11 |
2.5 |
|
50-315(I) |
50 |
17.5 |
4.86 |
128 |
30 |
2900 |
30 |
2.5 |
|
50-315(I)A |
50 |
16.6 |
4.61 |
115 |
30 |
2900 |
22 |
2.5 |
|
50-315(I)B |
50 |
15.7 |
4.36 |
103 |
39 |
2900 |
18.5 |
2.5 |
|
50-315(I)C |
50 |
14.4 |
4.0 |
86 |
38 |
2900 |
15 |
2.5 |
|
Fault phenomenon |
Possible causes |
Troubleshooting |
|
1. The water pump is not producing water |
a. The import and export valves are not open, the inlet and outlet pipelines are blocked, and the impeller flow channel is blocked. b. The motor is running in the wrong direction and has a slow speed due to phase loss. c. The suction pipe is leaking air. d. The pump is not filled with liquid and there is air inside the pump chamber. e. Insufficient imported water supply, high suction, and leaking bottom valve. f. Excessive pipeline resistance and improper pump selection. |
a. Check and remove blockages. b. Adjust the direction of the motor and tighten the motor wiring. c. Tighten all sealing surfaces and eliminate air. d. Open the pump cover or open the exhaust valve to exhaust the air. e. Shutdown inspection and adjustment. f. Reduce pipeline bends and reselect pumps. |
|
2. Insufficient water pump flow |
a. First, check the cause according to 1. b. The pipeline and pump impeller flow passage are partially blocked, with scale deposition and insufficient valve opening. c. The voltage is too low. d. Impeller wear. |
a. First, press 1 to exclude. b. Remove the obstruction and readjust the valve opening. c. Stabilize voltage. d. Replace the impeller. |
|
3. Excessive power |
a. Exceeding the rated flow usage. b. The suction distance is too high. c. The pump bearings are worn. |
a. Adjust the flow rate and turn down the outlet valve. b. Reduce suction distance. c. Replace the bearings. |
|
4. Noise vibration |
a. The pipeline support is unstable. b. Liquid mixed with gas. c. Generate cavitation. d. The bearing is damaged. e. The motor is overloaded and heats up during operation. |
a. Secure the pipeline. b. Increase suction pressure and exhaust. c. Reduce the vacuum level. d. Replace the bearings. e. Adjust according to 5. |
|
5. Motor overheating |
a. Excessive traffic and overloaded operation. b. Rubbing. c. The motor bearings are damaged. d. Insufficient voltage. |
a. Close the outlet valve. b. Check and eliminate. c. Replace the bearings. d. Stabilize voltage. |
|
6. Water pump leakage |
a. Mechanical seal wear. b. The pump body has sand holes or fractures. c. The sealing surface is uneven. d. Loosen the installation bolts. |
a. Replace. b. Welding repair or replacement. c. Repair. d. Tighten. |
Please provide as much as possible for ordering:
1. Model 2. Diameter 3. Head (m) 4. Flow rate 5. Motor power (KW) 6. Speed (R/min) 7. Material without accessories 8. Voltage (V)
Welcome to visit our Quanda Pump Valve【www.quandabf.cn】If you have any questions You can call us and we will do our best to provide you with high-quality service.