Fixed Freon Gas Detector

NegotiableUpdate on 04/08
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
ADT800W Rx fixed Freon gas detector is a new gas detector created by Outit Technology on the basis of the original, using original sensors and a new 32-bit low-power processor; The dashboard display interface displays both numerical values and progress bars, presenting a beautiful and elegant appearance; The circuit adopts 4-layer wiring, which has stronger resistance to weak signals and interference; Independent high-precision imported 16 bit AD chip and signal processing algorithm, with higher and more stable measurement data accuracy.
Product Details

ADT800W-RxFixed Freon Gas DetectorIt is a gas detector newly created by Outit Technology on the basis of the original, using original sensors and a new 32-bit low-power processor; The dashboard display interface displays both numerical values and progress bars, presenting a beautiful and elegant appearance; The circuit adopts 4-layer wiring, which has stronger resistance to weak signals and interference; Independent high-precision imported 16 bit AD chip and signal processing algorithm, with higher and more stable measurement data accuracy; 4~20mA, RS485, 200~1000HZ multiple output signals can be selected, making it easy to connect to various alarm controllers, PLCs, DCS and other control systems; Explosion proof structural design can be applied in various hazardous industrial sites; The product is widely used in various fields such as petrochemicals, gold mining, industrial manufacturing, municipal construction, power grid, underground pipeline maintenance, papermaking, fire protection, biopharmaceuticals, university experiments, scientific research units, etc.

ADT800W-RxFixed Freon Gas DetectorProduct Features:

High performance sensors with high measurement accuracy, good repeatability, and long service life;

Adopting an independent 16 bit AD chip and a 4-layer circuit board design, it has stronger resistance to weak signals and interference;

The dashboard display interface design features beautiful and elegant readings, reflecting humanized detail design;

◆ White, orange, and red backlight design, indicating normal and alarm status at a glance;

Multiple units including mg/m3, ppm, VOL, and LEL can be selected at the factory;

◆ Equipped with an embedded 32-bit ultra-low power processor and signal processing algorithms, it has fast response speed and stability;

◆ Automatic protection function against high concentration gas impact, with factory reset settings to prevent misoperation;

The instrument is equipped with an infrared remote control, which can be operated through the remote control without opening the cover, making it simple and convenient;

◆ Three wire system with 4-20mA, RS485, 200~1000HZ signal output options, relay output, data recovery, data storage and other functions;

Two cable entry ports for easy on-site installation;

◆ Independent chamber structure, easy sensor replacement, no need for on-site calibration;

Mechanical design, using high-quality high-strength aluminum profiles for the air chamber, wear-resistant, corrosion-resistant, and suitable for complex and harsh industrial environments. Reasonable and scientific air chamber design ensures the accuracy of real-time monitoring by sensors;

The explosion-proof level is Ex db IIC T6 Gb, certified by the National Explosion proof Electrical Inspection Center.

Technical parameters can be found on the following page:

Technical Specifications:

name

description

Gas detection:

Freon Rx

Detection Principle:

Thermal conductivity principle

Detection method:

Fixed online long-term continuous detection, diffusion based detection method;

Fixed online continuous detection, using an external air pump to achieve pump suction flow detection (optional air pump);

Installation method:

Wall mounted, pipe integrated (pipe type external thread specification: M45X1.5mm, optional pipe adapter screw joint, weldable)

Measurement range:

0-1000ppm,0-2000ppm,

resolving power:

1ppm(0-1000ppm)

Accuracy:

≤± 3% FS (actual concentration, higher accuracy requirements depending on sensor performance)

Operation method:

Infrared remote control for remote and close range operation, convenient setup

Repeatability:

≤±1%

Zero drift:

≤± 1% (F.S/year)

Response time:

≤ 30 seconds (T90)

Recovery time:

≤ 30 seconds

Explosion proof mark:

Exd II CT6

Protection level:

IP66

Output signal:

Users can choose according to their actual on-site environmental needs, with a maximum transmission distance of 2000 meters (single core 1mm2 shielded cable)

Three wire 4-20mA current signal output, can be connected to various control systems such as alarm controllers, PLCs, DCS, etc. (standard configuration)

Digital signal RS-485 output, ModBus RTU communication protocol (optional function)

Frequency signal 200~1000Hz output (optional function)

Two sets of relay outputs: passive electric shock capacity 220VAC 0.5A or 5VDC 0.5A

Remote transmission and status alarm of detection data can be achieved through wireless module function (optional function); Can achieve Ethernet access

Main material

Shell: ADC12 aluminum alloy, sturdy, wear-resistant and corrosion-resistant (batch can choose 316 stainless steel shell)

Gas chamber: Made of high-strength, wear-resistant, and corrosion-resistant aluminum profiles, sturdy and durable (316 stainless steel gas chambers can be optionally selected for batches)

Operating Temperature

-30 ℃~+60 ℃ (customized for special requirements)

Working humidity:

≤95%RH, No condensation (humidity>90% RH, condensation can be equipped with a filter)

relative humidity

10%~95%RH

Power supply:

24VDC (normal operating voltage range 12-30VDC)

Power consumption:

1.5W

working pressure:

≤200Kpa

Size:

180mm * 140mm * 92mm (height * width * thickness)

Weight:

About 1.6Kg

Execution standard:

GB15322.1-2003,GB3836.1-2010,GB3836.2-2010,GB3836.4-2010

Standard configuration:

Host, remote control, packaging box, manual, warranty card/certificate of conformity