G055 series industrial conductivity meterMain functions and features
1)It can measure one to four channels with one meter, and the models areDDG2022/A2/A3/A4;2)4.3Inch color display screen;3)Capacitive touch button;4)Chinese English menu switching, software menu friendly prompt operation;5)Recorder function, long-term storage of measurement data;6)Two output currents4-20mA;7)Three sets of relay contact outputs;8)Communication interfaceRS485;9)Equipped with temperature automatic compensation and electrode calibration and correction functions;10)Selection of AC wide voltage and DC power supply for power supply;11)Good sealing performance, multiple installation methods, etc.
G055 series industrial conductivity meterTwo main technical parameters
1、 Electronic unit:
1.1Measurement range and error
Conductivity:0.055~2~20us/cmError ± 1% F·S;0.055~200us/cmError ± 1%F·S;
0.055~2ms/cmError ±3%F·S; 0.055~100ms/cmError ±3%F·S.
temperature0~100℃ error ±0.5℃。
(Automatic range switching, with automatic temperature compensation enabled. Theoretical value is)0.055us/cm).
1.2Resolution: Conductivity0.001,temperature0.1.
1.3Automatic temperature compensation range:0~100℃。
1.4Protection level:IP67.
1.5Two way isolated output current and load:4~20mA(Measure the main value and temperature); load<750Oh.
1.6communication interfaceRS485 Modbus RTU.
1.7Three sets of relay contacts:3A240VAC,6A28VDCor120VAC.
1.8Power supply:85~260VAC,50~60Hzor24VDC.
1.9Quality: Approximately800g.
1.10Overall dimensionsmm:145×145×138Deep, embedded (disk mounted) installation hole size:130×130contain138×138.
There are multiple installation options available: this table is compatible with wall mounted or can be customized as an all-in-one cabinet machine.
1.11Working conditions: Environmental temperature:0~45℃; Relative humidity: not greater than90%;There is no interference except for the Earth's magnetic field.
2、 Sensor electrode:
2.1Electrode withstand water sample pressure:0.5MPato1MPa.
2.2Configure conductivity electrodes with different constants and conductivity values of different solution concentrations; Electrode constantK=0.01,0.1,1.0,10.0,30.0.
1)D2022Ttype/D2022BThe constant of the conductive electrode is0.01and0.1Suitable for high-purity water and pure water measurement, such as power plants, semiconductors, food and beverage pharmaceuticals, etc.
2)D608PThe conductivity electrode constant of the series is1.0and10.0Suitable for measuring ordinary aqueous solutions such as tap water, surface water, industrial processes, electroplating, and various water treatments.
2.3There are various installation methods for electrodes, such as flow type, pipeline type, and insertion type, and special installation methods can be customized.