G055 series industrial dissolved oxygen analyzerMain functions and features
1)4.3Inch color display screen;2)Capacitive touch button;3)Chinese English menu switching, software menu friendly prompt operation;4)Recorder function, long-term storage of measurement data;5)Two output currents4-20mA;6)Three sets of relay contact outputs;7)Communication interfaceRS485;8)One point air calibration with temperature compensation and electrode correction slope function;9)Selection of AC wide voltage and DC power supply for power supply;10)Good sealing performance, multiple installation methods, etc.
G055 series industrial dissolved oxygen analyzerTwo main technical parameters
1、 Electronic unit:
1.1Measurement range and error
Oxygen content:0.0~200ug/LError ± 0.1ug/L; 0.0~20mg/LError ±0.1mg/L.
temperature0~130℃ error ±0.5℃。
1.2Resolution: Oxygen Content0.01; Temperature0.1℃。
1.3Protection level:IP67.
1.4Automatic temperature compensation range:0~100℃。
1.5Two way isolated output current and load:4~20mA(Measure the main value and temperature); load<750Oh.
1.6communication interfaceRS485 Modbus RTU.
1.7Relay contacts:3A240VAC,6A28VDCor120VAC(Three groups).
1.8Power supply:85~260VAC,50~60Hzor24VDC.
1.9Quality: Approximately800g.
1.10Overall dimensionsmm:145×145×138Deep, embedded (disk mounted) installation hole size:130×130contain138×138.
There are multiple installation options available: this table is compatible with wall mounted or can be customized as an all-in-one cabinet machine.
1.11Working conditions: Environmental temperature:0~45℃; Relative humidity: not greater than90%;There is no interference except for the Earth's magnetic field.
2、 Basic parameters of sensor electrodes:
Sensor electrodes are divided intoug/Landmg/L.
1)028B2Type, measurement range: oxygen content0.0~200ug/L,0~80℃,Consumables inside the electrode:BJ2Oxygen membrane+Filling fluid; Suitable for measuring power plant boiler deaerator ≤7ug/L,Condensed water ≤50ug/L.
2)028W2type/028W3Type, measurement range: oxygen content0.0~20mg/L,0~60℃,The consumables inside the electrode are:WJ2Oxygen membrane/WJ3Oxygen membrane+Universal filling solution, suitable for ordinary aqueous solutions such as environmentally friendly water treatment, sewage measurement, etc.
3)028W6Type, measurement range: oxygen content0.0~20mg/L,0~80℃,The consumables inside the electrode are:W6Oxygen membrane/WJ6Oxygen membrane+Filling liquid, suitable for ordinary aqueous solutions, aquatic animal husbandry, environmentally friendly water treatment, sewage measurement, etc.
4)Oxygen electrode can withstand water sample pressure:0.5MPa.
5)There are various installation methods for electrodes, such as flow-through (power plant) and plug-in, and special installation methods can be customized.