German FISCHER Coating Thickness Gauge (Fischer, Germany)
The MPO dual-purpose coating thickness gauge is produced in Germany and combines the functions of a magnetic thickness gauge and an eddy current thickness gauge. It can be used to measure the thickness of coatings on iron-based and non-ferrous substrates.
1. Thickness of electroplated coatings such as copper, chromium, nickel, zinc, or coatings such as paint, coatings, enamel on steel materials.2. Thickness of anodized film on aluminum and magnesium materials.
3. Coating thickness on non-ferrous metal materials such as copper, aluminum, magnesium, zinc, etc.
4. The thickness of foil, tape materials such as aluminum, copper, and gold, as well as paper and plastic film.
5. Thickness of thermal spray coatings on various steel and non-ferrous metal materials.
GermanyThe FISCHER coating thickness gauge complies with the standards GB/T4956 and GB/T4957 and can be used for production inspection, acceptance inspection, and quality supervision inspection.
Features and Characteristics
1.This instrument adopts a dual function built-in probe, which does not require replacement of the probe. It can automatically identify iron-based or non-ferrous matrix materials and select the corresponding measurement method for * * measurement.
2. A dual display screen structure designed ergonomically, which can read measurement data at any measurement position.
3. Use the mobile menu to quickly select functions.
4. The instrument can set upper and lower limits. When the measurement result exceeds or meets the upper and lower limit values, the instrument will emit corresponding sounds or flash lights to indicate.
5. The instrument has good stability and can usually be measured for a long time without calibration.
2、 Main technical parameters:
◆ Range:0~2000μm。
◆ Accuracy:±1μm(0~50μm); ±2%(50μm~1000μm); ±3%(1000μm~2000μm)。
◆ Repetition accuracy:±0.5μm(0~100μm); ±0.5%(>100μm)。
◆ Small measurement of curvature diameter: within the accuracy range, iron-basedφ35mm, Non iron-based material with a diameter of 50mm; When the allowable error is less than 10%, the iron-based material is 10mm in diameter and the non-ferrous material is 2mm in diameter.
◆ Small measurement area diameter:When the allowable error is less than 10%, it is 2mm.
◆ Small substrate thickness: iron-based0.2mm (when the error is less than 10%);
Non iron based materials0.09mm (when the error is less than 10%).
◆ Weight:60g (excluding battery).
◆ Dimensions:64mm×30m×85mm。
◆ Power supply: two sectionsBattery No.5.
◆ One standard configuration host;
◆ One piece of iron and one piece of aluminum substrate each;
◆ One standard piece;