The latest research and developmentZOOMAC-H series high-end ultrapure water system, a unique and high-performance high-end ultrapure water system; Important parameters are clear at a glance, water quality data can be queried and traced, and everything is under control of the ultra pure water system.
Product performance characteristics:
*The product is made of engineering plastic ABS material, which is corrosion-resistant and resistant to acid and alkali, avoiding corrosion to the machine under strong acid or alkali conditions
*Adopting a newly developed 7-inch touch screen with independent intellectual property rights, the technology is people-oriented, the large interface has great achievements, the microcomputer fully automatic control system, multi-level menu operation, high precision, strong anti-interference ability, and digital operation throughout the entire process
*Ergonomic design, water and electricity separation structure, built-in hidden DC24V power supply, working voltage lower than the safe voltage for human body, convenient maintenance and replacement, ensuring safety
*Real time online monitoring of pure water and ultra pure water quality, dual display of digital and curve, equipped with USB interface for downloading water quality data
*Special factory and customer secondary passwords are set up, and the system settings are protected by passwords to prevent unauthorized changes
*Water production meets or exceeds the requirements of ASTM, NCCLS, ISO, or USP
*Specially designed quantitative water intake function (quantitative: 0.05-99L)
*Online display of date and running time
*Chip based consumables life alarm and reminder function, eliminating customers' worries
*Pure water and ultrapure water quality parameters can be freely set to provide different water quality requirements for different customers.
*Intelligent design: If the water quality of pure water production does not meet the set parameter values, it will automatically reflux, which meets the requirements of water resource conservation and ensures that the pure water in the storage tank is qualified.
*Intelligent design: If the water quality of ultra pure aquatic products cannot reach the set parameter values, automatic reflux ensures that customers obtain high-quality ultra pure water
*The water level of the storage tank can be digitally set, and the storage capacity can be set according to the customer's daily water consumption. Avoid storing pure water for too long without using it up in a timely manner, which can lead to a decrease in water quality
*Ultra pure water automatic circulation function ensures the sterility of the entire system. It has functions such as power on self-test, water shortage protection alarm, power outage automatic reset, automatic shutdown after the pure water tank is full of water, ultra-low pressure protection, UV lamp failure alarm, etc
*The accessories are connected using imported quick connectors, which are convenient, fast, and easy to maintain
*Adopting a dual type high water volume ultra purification column and imported Rohm and Haas resin process, it is easy to replace and has a long service life
*The device is capable of upgrading water quality and quantity in the later stage (function upgrade)
*Preprocessing RO、 The ultra purification component adopts a modular independent structure, which makes maintenance and filter replacement more convenient and complies with GLP standards
*Pure water pipelines and fittings have obtained NSF certification
*Fully automatic RO membrane anti scaling flushing (2-hour interval flushing), membrane pressure exceeding the set value and overpressure alarm
*Adopting a high-end water tank with a conical round bottom for easy cleaning (can be emptied), equipped with an air respirator to prevent bacteria from entering the water tank
Technical Specifications:
|
Product Model
system parameters |
ZWH-PA1-5/10/20/40 ZWH-PA2-5/10 Analytical(Low physical and chemical analysisTOC)) |
ZWH-LS1-5/10/20/40 ZWH-LS2-5/10 Life scienceLife Sciences Low Bacteria) |
ZWH-UT1-5/10/20/40 ZWH-UT2-5/10 Ultimate(High end comprehensive type) |
|
Water inlet requirements |
Urban tap water:TDS<200PPM,temperature5-45℃,Water pressure:0.2-0.4Mpa, When water entersTDS>200ppmIt is recommended to choose an external softener |
||
|
ROpure water |
onelevelROPure water(TDS)Conductivity ≈ source water conductivity*3%,Level 2ROpure water(TDS): 1-5us/cm(Conductivity ≤ source water conductivity*2%);Compliant with Chinese laboratory water standardsGB/T6682-2008Third level water standard |
||
|
UPultrapure water |
Electrical resistivity:18.25MΩ.CM@25℃ |
||
|
heavy metal ion |
<0.1ppb |
<0.1ppb |
<0.1ppb |
|
particle |
(0.22um)<1/ml |
(0.22um)<1/ml |
(0.22um)<1/ml |
|
bacteria |
<1cfu/ml |
<0.1cfu/ml |
<0.1cfu/ml |
|
heat source |
<0.25EU/ml |
<0.001EU/ml |
<0.001EU/ml |
|
TOC(PPb) |
1-3 |
<3 |
1-3 |
|
Deoxyribonucleic acid |
<4pg/ul |
<4pg/ul |
<4pg/ul |
|
Ribonucleic acid |
<0.01ng/ml |
<0.01ng/ml |
<0.01ng/ml |
|
出水口 |
2One:ROpure water,UP:ultrapure water |
2One:ROpure water,UP:ultrapure water |
2One:ROpure water,UP:ultrapure water |
|
Device dimensions |
600*410*580 |
600*410*580 |
600*410*580 |
|
Scope of Application |
Specialized for microanalysis: Water for routine laboratories at all levels, such as district and county disease control centers, quality inspection institutes, drug testing institutes, environmental monitoring stations, enterprise laboratories, and various high-end instruments |
Bioengineering, animal and plant cell culture, medium preparation, high-performance liquid chromatography, atomic absorption spectroscopy/Emission spectroscopy, mass spectrometry analysisTOCDetection, environmental testing, electrochemical interface research, development of biochips, and standard laboratories at all levels |
Molecular biology, life sciences, genetic research, tissue culture, in vitro fertilization, biotechnology, animal and plant cell culture, culture medium preparationDNASequencing, amino acid analysis, protein purification, toxicology research, biology/Water for pharmaceutical standard laboratories and various high-end precision instruments |