E-mail
bjhkmarket@126.com
-
Phone
18701521322
-
Address
Building 3, No. 69 Jinding North Road, Shijingshan District, Beijing
Beijing Huanke Environmental Protection Technology Co., Ltd
bjhkmarket@126.com
18701521322
Building 3, No. 69 Jinding North Road, Shijingshan District, Beijing
HBCODMn-The Type 1 online permanganate index analyzer automatically completes water sample collection through the control of an embedded industrial computer system. The water sample enters the reaction chamber and is heated by the analyzer controlled heating device. A quantitative oxidant and catalyst are added in sequence to the reaction chamber for digestion at 100 ℃. The digestion time can be determined based on the quality of the raw water, and the time that can completely digest COD is selected. After the digested sample is cooled for an appropriate period of time, the analyzer pumps a quantitative reducing agent, and then the standard concentration oxidant is dripped back. The voltage related to the endpoint chromaticity is detected by the photoelectric colorimetric method to determine the titration endpoint. After data processing, embedded industrial computers display permanganate index values and store, process, and transmit data. After measurement, the system and reaction chamber will be automatically cleaned with pure water. This instrument can be widely used for measuring the permanganate index of drinking water, surface water, and surface water.
The instrument adopts a large screen graphic dot matrix LCD display, which can display the process flow of the entire analysis process, intuitively display the measurement results, and also display reports and curves.
The instrument automatically performs zero calibration for each analysis.
4mA~20mA correspond to linear output between zero and full range, respectively.
The instrument is equipped with a large capacity electronic hard drive that can store measurement data for ten years of continuous operation.
Set the remaining amount of reagents. When the remaining amount of reagents falls below the lower limit, the instrument will stop running and sound an alarm.
The processes of adding samples, adding drugs, heating, and discharging waste liquids can be manually completed through the keyboard.
According to changes in water quality concentration, the equipment automatically switches between standard range and high concentration range to ensure measurement accuracy.
In conjunction with an automatic water quality sampler, it can achieve the function of retaining samples that exceed the standard.
In conjunction with the flow meter, it is possible to not analyze the discharge outlet when there is no water or little drainage, and to analyze it again when there is water, in order to protect the water collection equipment and analytical instruments.
When the reaction solution in the reaction tube is significantly insufficient, the instrument will automatically stop and display "fault".
Through the RS232 interface of the instrument, data acquisition and control of the instrument can be achieved. The instrument is equipped with multiple communication protocols and can be customized according to user needs.