E-mail
1198054271@qq.com
-
Phone
13914526960
-
Address
Mingjing Road, Madian, Binjiang Town, Taixing City (formerly a refrigeration plant)
Taixing Hengsheng Pump Equipment Manufacturing Factory
1198054271@qq.com
13914526960
Mingjing Road, Madian, Binjiang Town, Taixing City (formerly a refrigeration plant)
HC-40S slide type blower air flow range: 0.67-0.8m3/min, blower pressure range: 0.1-0.5kgf/cm2. The motor has a power of 1.5kw, a diameter of 32mm, a speed of 580rpm, and a net weight of 85kg.

HC-401S small fan_Small fan_Small aerator blower (slide type blower,Rotary fan,Sliding blade fan)Detailed description of
1. Fan, Small Blower, Small Aeration Blower (Sliding Blade Fan, Rotary Fan, Sliding Blade Fan) Main Applications:
● Water treatment blast aeration
● Sewage mixing and aeration in hospitals and laboratories
Vacuum paper feeding in the printing industry
Mixing and aeration of electroplating tanks and industrial wastewater
● Gas supply for plastic welding and blowing
● Burner spray, glass industry
2. HC-401S Fan _ Small Blower _ Small Aeration Blower
Airflow: 0.8-0.67m3/m3
3. HC-401S Small Fan _ Small Blower _ Small Aeration Blower
Pressure: 0.1kgf/cm2-0.5kgf/cm2
Pressure unit conversion: 9.8kPa=0.1kgf/cm2=1000mmH2O=73.5mmHg=98mbar r=0.0967atm
4. HC-401S small fan, small blower, small aeration blower noise ≤ 53db
Detection conditions and methods for noise of sliding blade fan
1、 Fan installation section
1. The fan needs to have a foundation or be equipped with vibration reducing components
2. The air outlet needs to be connected to the pipeline equipment
3. The fan pressure should be within the specified range (pressure gauge shows 0-0.05MPa)
4. The inner wall of the fan room needs to be equipped with sound-absorbing materials to reduce noise
2、 Testing method
1. Inspection outside the fan room: Testing at a distance of 2-6 meters from the fan room will reduce the fan noise test value to the standard value.
In addition, the size of the fan room and the surrounding environment also have an impact on the noise test values. (First, meet the installation requirements)
2. Open space detection: Within 20 meters of the tested fan, there are no obvious buildings or other obstacles that can produce echoes. The fan is equipped with vibration reduction components and tested under no-load operation (30ml of lubricating oil is poured into the air inlet before the detection, and the running time cannot exceed 5 minutes). The fan noise test value will be reduced to the standard value when tested 1-10 meters away from the fan. The environment also has an impact on the noise test value.
3 Sensory detection: The fan has no abnormal noise, no inorganic collision noise, no abnormal vibration without overpressure, no intake noise, motor operation noise, and ground micro vibration are all normal sounds.
Technical parameters of slide type blower
| model | exhaust |
motor power (kw) |
frequency |
fan |
Airflow (m3/min) | V-belt pulley |
V-shaped belt |
Fuel tank storage fuel level (Effective fuel quantity) |
Weight (kg) |
||||||
0.1kgf |
0.2kgf |
0.3kgf |
0.4kgf /cm2 |
0.5kgf |
blower | motor | net weight |
hair volume |
|||||||
HC-120S |
3/4'(20) | 0.25 |
50 | 450 | 0.12 | 0.115 | 0.110 | 0.105 | 0.100 | 6” |
11/2' | A-40 |
2.0L(1.5L) |
35 |
38 |
HC-150S |
3/4'(20) |
0.25 |
50 | 580 |
0.156 |
0.150 | 0.145 |
0.140 |
0.138 |
6” |
2' |
A-40 |
2.0L(1.5L) | 35 |
38 |
HC-200S |
3/4'(20) | 0.37 |
50 | 680 |
0.210 |
0.205 |
0.200 | 0.195 | 0.190 | 6' | 2' | A-40 |
2.0L(1.5L) | 38 |
41 |
HC-251S |
3/4'(20) | 0.55 | 50 | 450 |
0.31 | 0.30 | 0.29 |
0.28 | 0.28 |
8' |
21/2' |
A-40 |
1.5L(1.1L) |
44 |
51 |
HC-30S |
1'(25) |
0.55 | 50 | 430 | 0.35 |
0.34 |
0.33 |
0.32 |
0.31 |
10' |
3' |
A-44 |
1.5L(1.1L) |
50 |
57 |
HC-301S |
1'(25) | 0.75 | 50 | 520 | 0.42 |
0.41 | 0.4 |
0.39 |
0.38 |
10' |
31/2' |
A-44 |
1.5L(1.1L) |
50 |
57 |
HC-40S |
11/4'(32) | 0.75 |
50 | 500 | 0.66 | 0.65 |
0.63 |
0.61 |
0.59 | 12' |
4' |
A-52 |
2.5L(1.7L) |
80 |
88 |
| HC-401S | 11/4'(32) | 1.5 |
50 | 580 | 0.8 |
0.77 | 0.74 |
0.71 |
0.67 |
12' |
41/2' |
A-52 |
2.5L(1.7L) |
85 | 93 |
HC-50S |
11/2'(40) | 1.5 |
50 | 430 | 1.14 |
1.12 |
1.09 |
1.06 |
1.02 |
14' |
4' |
A-64 |
3.5L(2.3L) | 120 |
130 |
HC-501S |
11/2'(40) | 2.2 |
50 | 500 | 1.44 |
1.42 |
1.39 |
1.36 | 1.32 |
14' |
41/2' |
A-64 |
3.5L(2.3L) |
125 | 135 |
HC-60S |
2'(50) | 2.2 | 50 | 450 | 1.9 |
1.87 | 1.82 |
1.77 | 1.71 |
16' |
5' |
B-74 |
5.5L(3.8L) | 190 | 223 |
HC-601S |
2'(50) | 4 | 50 | 540 | 2.41 | 2.34 | 2.29 | 2.24 | 2.18 | 16' | 6' | B-74 | 5.5L(3.8L) | 200 | 233 |
HC-80S |
21/2'(65) | 4 | 50 | 430 | 2.82 | 2.74 | 2.66 | 2.59 | 2.5 | 18' | 51/2 | B-84 | 8L(6L) |
250 | 268 |
HC-801S |
21/2'(65) | 5.5 | 50 | 500 | 3.53 | 3.45 | 3.38 | 3.33 | 3.25 | 18' | 6' | B-84 | 8L(6L) | 275 | 293 |
HC-100S |
3'(80) | 5.5 | 50 | 390 | 4.32 | 4.28 | 4.25 | 4.18 | 4.11 | 20' | 51/2' | B-93 | 20L(16L) | 375 | 395 |
HC-1001S |
3'(80) | 7.5 | 50 | 420 | 5.41 | 5.32 | 5.25 | 5.18 | 5.11 | 20' | 6' | B-93 | 20L(16L) | 390 | 410 |
HC-125A |
4'(100) |
7.5 |
50 |
390 |
6.87 |
6.82 |
6.78 |
6.63 |
6.58 |
20' |
6' |
B-93 |
30L(25L) |
580 |
600 |
HC-125B |
4'(100) |
11 |
50 |
420 |
7.83 |
7.81 |
7.78 |
7.75 |
7.72 |
20' |
6' |
B-93 |
30L(25L) |
600 |
620 |
HC-125C |
4'(100) |
11 |
50 |
500 |
9.20 |
9.10 |
9.0 |
8.80 |
8.70 |
20' |
6' |
B-93 |
30L(25L) |
600 |
620 |
Installation dimensions of sliding blade fan