HC-601S Rotary Blower

NegotiableUpdate on 03/25
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
HC-601S Rotary Blower The air flow range of HC-601S Rotary Blower is 2.41-2.18m3/min, and the blower pressure range is 0.1-0.5kgf/cm2. Motor power 4kw, diameter 50mm, speed 540rpm, net weight 200kg
Product Details

HC-601SRotary blowerAirflow range: 2.41-2.18m3/min, blower pressure range: 0.1-0.5kgf/cm2. Motor power 4kw, diameter 50mm, speed 540rpm, net weight 200kg.

回转式风机图片 (1).jpg


HC-601S Blower Rotary Fan_Rotary fanDetailed description of

1. Rotary fan (rotary fan,Sliding blade fan)Main purpose and characteristics: (illustrated)

Purpose of rotary blower:

● Water treatment blast aeration

● Sewage mixing and aeration in hospitals and laboratories

Vacuum paper feeding in the printing industry

Mixing and aeration of electroplating tanks and industrial wastewater

● Gas supply for plastic welding and blowing

● Burner spray, glass industry

Characteristics of rotary blower:

Small size, high air volume, low noise, and low energy consumption (Rotary blowers use the principle of operating compressed air. Although small in size, they have high air volume, energy efficiency, and silent operation that other forms of fans cannot compare to.)

Smooth operation and easy installation (For small models, as long as they are properly placed, the vibration is minimal and there is no need to install anti vibration devices, making installation convenient.)

● Resistance to load changes and stable air flow (for example, if the pressure of the aeration tank in sewage treatment changes, the load changes, but the air flow changes very little with pressure changes)

Equipped with an air chamber for smooth air dispersion (All models come with an air chamber to prevent air pulsation and ensure smooth air dispersion.)

The material is excellent, the structure is clever, and the performance is outstanding (the blower is made of high-quality materials, with exquisite structure, sturdy and durable, excellent performance, and few long-term failures)

Easy maintenance, few malfunctions, long lifespan (low speed, minimal wear, long lifespan)

2. HC-601S blower, rotary fan, rotary fan, air volume: 2.41-2.18m3/min

The fan air volume Qs refers to the inlet flow rate of a rotary blower in a standard suction state (pressure 101.325kPa, temperature 20 ℃, relative humidity 50%) with air as the medium, and is converted for flow segments in non-standard states.

3. HC-601S Blower, Rotary Fan, Rotary Fan

Pressure: 0.1-0.5kgf/cm2

Pressure unit change: 9.8kPa=0.1kgf/cm2=1000mmH2O=73.5mmHg=98mbar r=0.0967atm

4. HC-601S blower, rotary fan, rotary fan noise ≤ 60db

Detection conditions and methods for noise of rotary fans

1、 Fan installation section

1. The fan needs to have a foundation or be equipped with vibration reducing components

2. The air outlet needs to be connected to the pipeline equipment

3. The fan pressure should be within the specified range (pressure gauge shows 0-0.05MPa)

4. The inner wall of the fan room needs to be equipped with sound-absorbing materials to reduce noise

2、 Detection method for rotary fan

1. Inspection outside the fan room: Testing at a distance of 2-6 meters from the fan room will reduce the fan noise test value to the standard value.

In addition, the size of the fan room and the surrounding environment also have an impact on the noise test values. (First, meet the installation requirements)

2. Open space detection: Within 20 meters of the tested fan, there are no obvious buildings or other obstacles that can produce echoes. The fan is equipped with vibration reduction components and tested under no-load operation (30ml of lubricating oil is poured into the air inlet before the detection, and the running time cannot exceed 5 minutes). The fan noise test value will be reduced to the standard value when tested 1-10 meters away from the fan. The environment also has an impact on the noise test value.

3 Sensory detection: The fan has no abnormal noise, no inorganic collision noise, no abnormal vibration without overpressure, no intake noise, motor operation noise, and ground micro vibration are all normal sounds.

Technical parameters of rotary blower

model

exhaust
caliber
(mm)

motor
power
(kw)

frequency
(HC-S)

fan
speed
(rpm)

Airflow (m3/min)

V-belt pulley

V-shaped
belt
Fuel tank storage
fuel level
(Effective fuel quantity)

Weight (kg)

0.1kgf
/cm2

0.2kgf
/cm2

0.3kgf
/cm2

0.4kgf
/cm2

0.5kgf
/cm2

blower motor

net weight

Gross volume

HC-120S

3/4'(20)

0.25

50 450 0.12 0.115 0.110 0.105 0.100

6”

11/2'

A-40

2.0L(1.5L)

35

38

HC-150S

3/4'(20)

0.25

50

580

0.156

0.150

0.145

0.140

0.138

6”

2'

A-40

2.0L(1.5L)

35

38

HC-200S

3/4'(20)

0.37

50

680

0.210

0.205

0.200 0.195 0.190 6' 2'

A-40

2.0L(1.5L)

38

41

HC-251S

3/4'(20) 0.55 50

450

0.31 0.30

0.29

0.28

0.28

8'

21/2'

A-40

1.5L(1.1L)

44

51

HC-30S

1'(25)

0.55 50 430

0.35

0.34

0.33

0.32

0.31

10'

3'

A-44

1.5L(1.1L)

50

57

HC-301S

1'(25) 0.75 50 520

0.42

0.41

0.4

0.39

0.38

10'

31/2'

A-44

1.5L(1.1L)

50

57

HC-40S

11/4'(32)

0.75

50 500 0.66

0.65

0.63

0.61

0.59

12'

4'

A-52

2.5L(1.7L)

80

88
HC-401S 11/4'(32)

1.5

50 580

0.8

0.77

0.74

0.71

0.67

12'

41/2'

A-52

2.5L(1.7L)

85 93

HC-50S

11/2'(40)

1.5

50 430

1.14

1.12

1.09

1.06

1.02

14'

4'

A-64

3.5L(2.3L)

120

130

HC-501S

11/2'(40)

2.2

50 500

1.44

1.42

1.39

1.36

1.32

14'

41/2'

A-64

3.5L(2.3L)

125 135

HC-60S

2'(50) 2.2 50 450

1.9

1.87

1.82

1.77

1.71

16'

5'

B-74

5.5L(3.8L) 190

223

HC-601S

2'(50) 4 50 540 2.41 2.34 2.29 2.24 2.18 16' 6' B-74 5.5L(3.8L) 200 233

HC-80S

21/2'(65) 4 50 430 2.82 2.74 2.66 2.59 2.5 18' 51/2 B-84

8L(6L)

250 268

HC-801S

21/2'(65) 5.5 50 500 3.53 3.45 3.38 3.33 3.25 18' 6' B-84 8L(6L) 275 293

HC-100S

3'(80) 5.5 50 390 4.32 4.28 4.25 4.18 4.11 20' 51/2' B-93 20L(16L) 375 395

HC-1001S

3'(80) 7.5 50 420 5.41 5.32 5.25 5.18 5.11 20' 6' B-93 20L(16L) 390 410

HC-125A

4'(100)

7.5

50

390

6.87

6.82

6.78

6.63

6.58

20'

6'

B-93

30L(25L)

580

600

HC-125B

4'(100)

11

50

420

7.83

7.81

7.78

7.75

7.72

20'

6'

B-93

30L(25L)

600

620

HC-125C

4'(100)

11

50

500

9.20

9.10

9.0

8.80

8.70

20'

6'

B-93

30L(25L)

600

620

Installation dimensions of rotary fan