Phone
13911124730
-
Address
Building 11, No.1 Chaoqian Road, Changping District Science and Technology Park, Beijing
Beijing Jiaxin Hengsheng Environmental Protection Technology Co., Ltd
13911124730
Building 11, No.1 Chaoqian Road, Changping District Science and Technology Park, Beijing

HS-803 Sodium Ion Monitor
Application field
Widely used for online monitoring of sodium ions in power plant feedwater, boiler feedwater, steam and condensate water, and semiconductor process water.
Main features
1. Full Chinese LCD graphic display, menu style operation, convenient, fast, simple and easy to use.
2. Flow verification eliminates pollution and improves accuracy.
3. Measure pH value and automatically sound an alarm when the alkalization effect is not good. High precision electrode, high measurement accuracy, wide range.
4. Imported electrodes have a long service life and good stability.
5. High precision programmable current signal output, suitable for subsequent automatic dosing or data acquisition systems.
6. Power off storage function, data storage for more than 15 years.
7. Exquisite structure, disc installation, easy to use and maintain.
8. Waterproof and dustproof design, suitable for outdoor use.
9. Two point standard calibration can be automatically performed according to the user's set time cycle, reducing maintenance workload.
Main technical parameters
1、 量 程 pNa:1.00~8.00pNa Na+:23g/L~0.23μg/L mV:±1000mV pH:0~14pH Temp:0~85℃
2. Resolution pNa: 0.01pNa Na+: 0.01ug/L mV: 0.1mV pH: 0.01pH Temp: 0.1 ℃
3、 精 度 Na+/pNa:±1.5%F. S pH:±0.1pH mV:±1mV Temp:±0.3℃
4. Repeatability: ± 1.5% F.S
5. Stability: ± 1.5% F.S/24h
6. Temperature electrode: Pt1000
7. Temperature compensation: automatic temperature compensation 0-65 ℃
8. Calibration method: Two point calibration (sample calibration, standard solution calibration)
9. Response time:<2 minutes
10. Sampling period: 2 minutes
11. Water sample requirement flow rate: 10-40L/h Temperature: 0.1-60 ℃ Impurities: Solid matter less than 5 microns, and no gel like substance appears
12. Environmental temperature: 5-45 ℃ (accuracy decreases above 40 ℃)
13. Environmental humidity: not exceeding 90% RH (no condensation)
14. Reagent consumption: 1.5L/month for each type, one type (diisopropylamine)
15. Output signal: Two channels of 4-20mA (range optional) current signal corresponding to sodium ion concentration value can be set arbitrarily
16. Alarm signal: water temperature overheating and upper and lower limit alarm
17. Communication interface: RS485 or 232 (optional)
18. Protection level: IP65
19. Data retention: 15 years
20. Power supply: 220V ± 22V, 50Hz ± 1Hz
21. Power: 50W
22. Dimensions: 720 × 460 × 300 mm (H × W × D)
23. Hole size: 665 × 405mm (H × W)
24. Weight: 15kg
Selection Guide
1. Two ion monitoring devices, namely cation bed sodium and vapor sodium, can be optionally equipped.
2. Installation methods include disc installation and wall mounted installation.