High temperature and high pressure module of in-situ nuclear magnetic resonance experimental system

NegotiableUpdate on 02/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
MacroMR12-150H-I Large Bore Nuclear Magnetic Resonance Imaging Analyzer with In Situ Nuclear Magnetic Resonance Experimental System High Temperature and High Pressure Module Application: Reservoir Physical Property Analysis - Porosity/Pore Size Distribution, Oil/Water Saturation, Mobile/Bound Fluid Saturation, Permeability, Wettability Evaluation/Layered Water Content Non Conventional Energy - Isothermal Adsorption and Desorption of Shale Gas/Coalbed Methane, CO2 Competitive Adsorption Experiment, Natural Gas Hydrate Generation/Decomposition, Gas Water Two Phase Dynamic Displacement Analysis, Supercritical CO2 Fracturing/Gas Displacement Evaluation of Oil and Gas Reservoir Development - Quantitative Testing and Analysis of Fracture Development during Fracturing Process, Acidification
Product Details

In fields such as materials science, geological exploration, and energy development, the physical and chemical properties and microscopic behavior of many substances undergo significant changes under high temperature and pressure environments. For example, the migration law of oil and gas in underground reservoirs, the phase transition process of minerals in deep geological layers, and the application of new materialsExtreme endThe performance under working conditions is closely related to high temperature and high pressure conditions.High temperature and high pressure module of in-situ nuclear magnetic resonance experimental systemThe emergence of provides researchers with opportunities in simulationExtreme endA powerful tool for real-time and precise exploration of the essence of matter in the environment, whichDuTe-The value lies in the breakthrough of traditional research methods and the deep adaptation to complex scenarios.

Traditional research methods are inadequate in addressing these challenges. Offline testing methods may cause irreversible changes in the microstructure of samples after they are released from high temperature and high pressure environments, such as fluid escape from pores and decomposition of phase change products, resulting in severe data distortion; The indirect inference method infers micro mechanisms by measuring macroscopic performance, making it difficult to establish a clear "structure performance" correlation and unable to touch on essential laws. Although the static simulation method can provide high-temperature and high-pressure environments, it cannot monitor internal changes in real time and miss key information in the dynamic evolution process. These limitations make it difficult for traditional methods to meet the urgent need for "real-time, in-situ, and accurate" research on material properties in high-temperature and high-pressure environments.

The MacroMR12-150H-I large aperture nuclear magnetic resonance imaging analyzer launched by Suzhou Neway Analytical Instrument Co., Ltd. is equipped withHigh temperature and high pressure module of in-situ nuclear magnetic resonance experimental systemBy virtue ofZhuo YueThe technical performance and wide application value have broken through the limitations of traditional research methodsExtreme endLimitations in environmental research. It realizes in-situ, real-time, and quantitative analysis of material microstructure, fluid behavior, and chemical reactions, revealing the essential laws of matter under high temperature and high pressure for basic research, and providing accurate data support for optimizing energy extraction in industrial practice.

原位核磁共振实验系统高温高压模块


equipped withHigh temperature and high pressure module of in-situ nuclear magnetic resonance experimental systemMacroMR12-150H-I Large Aperture Magnetic Resonance Imaging Analyzer Basic Parameters:

Magnetic field strength: 0.3T ± 0.03T

Injection direction: Horizontal

Magnet shape: C-shaped open type

Temperature parameters: Room temperature -80 ℃

Pressure parameters: 0-20/40/70Mpa (different probe configurations)

Sample requirements: diameter ≤ 150mm, length ≤ 100mm (normal temperature and pressure)

1 inch diameter core, length ≤ 80mm (high-temperature and high-pressure displacement)

equipped withHigh temperature and high pressure module of in-situ nuclear magnetic resonance experimental systemApplication of MacroMR12-150H-I Large Aperture Magnetic Resonance Imaging Analyzer:

Reservoir physical property analysis - porosity/pore size distribution, oil/water saturation, movable/bound fluid saturation, permeability, wettability evaluation/layered water content

Unconventional Energy - Isothermal Adsorption and Desorption of Shale Gas/Coalbed Methane, CO2 Competitive Adsorption Experiment, Natural Gas Hydrate Formation/Decomposition, Gas Water Two Phase Dynamic Displacement Analysis, Supercritical CO2 Fracturing/Gas Displacement

Evaluation of oil and gas reservoir development - quantitative testing and analysis of fracture development during fracturing process, online analysis of pore development during acidification process

Analysis and evaluation of oil-water two-phase high-temperature and high-pressure visualization displacement experiment, online testing and analysis of polymer displacement and chemical displacement, analysis of micro pore permeability parameters under load (confining pressure/water pressure) conditions, analysis of triaxial compression damage, analysis of infiltration and absorption process and characteristics

Application case of MacroMR12-150H-I large aperture magnetic resonance imaging analyzer:

原位核磁共振实验系统高温高压模块


Suzhou Neway's after-sales service:

Pre sales service: in-depth experience, precise selection

Neway has a professional customer experience center and welcomes customers to visit the site in person,Zero distanceContact and operate equipment to intuitively feel its performance and usability. Through on-site experience and professional explanations from consultants, help customers accurately evaluate whether the equipment meets their application needs.

After sales support: fast response, professional guarantee

Quick response mechanism: We promise to respond within 4 hours and provide a solution within 8 hours. If remote solutions are not possible, engineers will arrive within 24 hours in provincial capitals and 72 hours in remote areas, including holidays. Ensure that users receive timely and effective handling when encountering problems, minimizing the impact of equipment downtime.

Professional team configuration: We have a highly educated service team of nearly 20 people, with master's degrees accounting for over 60%. We have a strong technical foundation and customized service capabilities to ensure that complex problems are solved professionally and efficiently.

Multiple communication channels: support telephone QQ、 WeChat and other various methods provide convenient and flexible communication, and can respond to customer needs at any time.

User training empowerment: Neway has established a normalized training system. In addition to holding regular application training courses, it also provides flexible online and offline daily training. Users can obtain software and hardware training videos anytime and anywhere through "Newmark Analysis", "Newmark Service" WeChat official account and "Nuclear Magnetic Research Energy Station" applet, and continuously improve their operation skills and application level,MaximizationEquipment value.

Proactive service culture: Adhering to the concept of "achieving customer success and taking responsibility", engineers actively follow up, proactively solve problems, help customers reduce unnecessary repair processes, save time and energy. Based on customer feedback, they continuously optimize service processes and grow together with customers.

Device QR code identification: Each device is equipped with a QR code identification, and customers can quickly obtain online support entry by scanning the code, greatly improving service response efficiency and convenience.

Full dimensional service centers cover the whole country: Neway has 7 full dimensional service centers located in Shanghai, Suzhou, Chengdu, Guangzhou, Zhengzhou, Beijing, and Taiyuan, covering all regions of China, ensuring that service resources can quickly reach customers across the country.