1、 Product Introduction
Ionic chromatography column is the separation system of ion chromatography system, which is one of the core components of ion chromatography and also one of the most commonly used consumables. The currently most widely used ion exchange ion chromatography column is mainly used for analyzing charged anions and cations, small molecule organic acids, etc. in samples, such as Cl - SO42-、K+、Na+、 Citric acid, etc. According to the analysis of ion types, they can be roughly divided into two categories: anion chromatography columns and cation chromatography columns
Anion chromatography column is mainly used to analyze anions in samples. The eluent (mobile phase) mainly includes carbonate system and hydroxide system, which can be selected according to the detection requirements. The hydroxide system chromatographic column has an advantage over the carbonate system in trace detection due to its lower conductivity background.
Cation chromatography column is mainly used to analyze cations in samples, and the eluent (mobile phase) is mainly methane sulfonic acid.
Note: It is necessary to distinguish between liquid and gas chromatography columns. The substances separated by ion chromatography columns are charged inorganic salt ions. Liquid chromatography columns mainly analyze organic compounds, while gas chromatography columns mainly analyze volatile organic substances.
2、 Product parameters
Example of SH series commonly used chromatographic columns
|
Serial number |
number |
type |
Specifications |
structural style |
function |
remarks |
Analysis system |
|
1 |
SH-AC-1 |
Anion chromatography column |
4.6*250mm |
Latex agglomeration |
Can simultaneously analyze 6 common anions: Cl-、 NO2-、 Br-、 NO3-、 H2PO4-、 SO42-。 |
Suitable for detecting common anions such as environmental protection and cement. |
The carbonate system |
|
2 |
SH-AC-4 |
Anion chromatography column |
4.6*250mm |
Surface grafting |
Analyze 7 common anions: F -, Cl -, NO2-, Br -, NO3-, H2PO4-, SO42-, and BrO3- in flour; Some organic acids such as oxalic acid and tartaric acid. |
Suitable for various industries such as food, environment, metallurgy, geology, etc. |
The carbonate system |
|
3 |
SH-AC-11 |
Anion chromatography column |
4.6*250mm |
Surface grafting |
Bromate analysis; Analysis of 7 common anions including F -, Cl -, NO2-, Br -, NO3-, H2PO4-, SO42-, etc; Disinfection by-products in drinking water: ClO2-、 BrO3-、 ClO3-、 Analysis of monochloroacetic acid, dichloroacetic acid, and trichloroacetic acid. |
Suitable for various industries such as drinking natural mineral water, packaged drinking water, and domestic drinking water. |
Hydroxide system |
|
4 |
SH-CC-3 |
Cation chromatography column |
4.6*100mm |
graft |
Polymer matrix weak acid cation chromatography column, analyzing six common cations: Li+、Na+、NH4+、K+、Mg2+、 Ca2+。 |
Suitable for common cation analysis in various industries such as environment, water quality, medical, food, etc., with organic solvent tolerance<30% acetone. |
Methanesulfonic acid |