1、 Product Introduction
JC-SR-3100CGrounding resistance·The soil resistivity tester is specially designed and manufactured for on-site measurement of grounding resistance, soil resistivity, grounding voltage, and AC voltage. It uses digital and microprocessing technology to achieve precision4Line method3Line method and simplicity2Line method for measuring grounding resistance, importFFT(fast fourier transform)TechnologyAFC(Automatic frequency control)Technology that automatically identifies interference and selects measurement frequency. The instrument casing adopts a waterproof protective box, which is anti-collision, anti drop, and waterproof (protection level)IP65)Durable and sturdy, especially suitable for use on outdoor construction sites. It is widely used for measuring grounding resistance, soil resistivity, grounding voltage, and AC voltage in power, telecommunications, meteorology, oil fields, buildings, lightning protection, and industrial electrical equipment.
2、 Product parameters
|
Influence quantity |
Benchmark conditions |
Working conditions |
remarks |
|
|
ambient temperature |
23℃±1℃ |
-10℃~40℃ |
---- |
|
|
Environmental Dampness Crossing |
40%~60% |
<80% |
---- |
|
|
Instrument working voltage |
9V±0.1V |
9V±1.5V |
---- |
|
|
Auxiliary grounding resistance value |
<100Ω |
<30kΩ |
rC、rP |
|
|
Interference voltage |
nothing |
<20V |
---- |
|
|
Interference current |
nothing |
<2A |
---- |
|
|
measureRDistance between time electrodes |
a>5d |
a>5d |
---- |
|
|
measureρDistance between time electrodes |
a>20h |
a>20h |
---- |
|
|
Gong Gongcan |
Measurement of grounding resistance and soil resistivity using two, three, and four wires;Measurement of grounding voltage and AC voltage |
|||
|
electricsource |
DC 9V (Zinc manganese dry batteryR14S 1.5V 6Section, continuous standby300hour) |
|||
|
amountCheng |
Grounding resistance: 0.00Ω~30.00kΩ |
|||
|
Soil resistivity: 0.00Ωm~9000kΩm |
||||
|
Measurement method |
precise4Line3Line measurement, simple2Line measurement of grounding resistance |
|||
|
Short circuit test current |
AC 20mA max |
|||
|
Open circuit test voltage |
AC 40V max |
|||
|
Test voltage waveform |
sine wave |
|||
|
Range of electrode spacing |
Can be set1m~100m |
|||
|
changefiles |
Grounding resistance: 0.00Ω~30.00kΩFully automatic gear shifting |
|||
|
Soil resistivity: 0.00Ωm~9000kΩmFully automatic gear shifting |
||||
|
Backlight |
Controllable blue screen backlight, suitable for use in dark fields |
|||
|
display mode |
4Extra large sizeLCDDisplay, blue screen backlight |
|||
|
Measurement indication |
Measuring in progressLEDtwinkle,LCDCountdown,Progress bar chart indication |
|||
|
LCDsize |
128mm×75mm |
|||
|
LCDDisplay Domain |
124mm×67mm |
|||
|
Instrument size |
High, Wide, and Thick: 215mm×190mm×95mm |
|||
|
Standard testing line |
4strip:red20m, Black20m, Yellow10m, Green10mvarious1strip |
|||
|
Simple testing line |
2strip:red1.6m, Black1.6mvarious1strip |
|||
|
Auxiliary grounding rod |
4root: φ10mm×150mm |
|||
|
Measurement time |
Ground voltage:about3second/second |
|||
|
Grounding resistance and soil resistivity:about5second/second |
||||
|
Measurement frequency |
5000More than once(Short circuit test, testing1Next time, stop30Test again in seconds) |
|||
|
Line voltage |
AC 600VThe following measurements |
|||
|
RS232Interface |
haveRS232Interface, software monitoring, data storage can be uploaded to the computer, saved and printed |
|||
|
Communication line |
RS232Communication line1Article, long1.5m |
|||
|
data storage |
300Group,"MEM"Storage indication, display"FULL"The symbol indicates that the storage is full |
|||
|
Data retention |
When maintaining data"HOLD"Symbol indication |
|||
|
Data retrieval |
When consulting data"READ"Symbol indication |
|||
|
Overflow display |
When there is an overflow of over range"OL"Symbol indication |
|||
|
Interference testing |
Automatically identify interference signals, interference voltage higher than5VWhen"NOISE"Symbol indication |
|||
|
Gong GongConsumption |
Standby mode:about20mA(Backlight off) |
|||
|
Turn on the backlight when turned on:about45mA(Backlight off25mA) |
||||
|
measure:about100mA(Backlight off) |
||||
|
qualityamount |
Total Quality: 4.5kg (Including packaging) |
|||
|
Working temperature and humidity |
-10℃~40℃; 80%rhfollowing |
|||
|
Storage temperature and humidity |
-20℃~60℃; 70%rhfollowing |
|||
|
overload protection |
Measure the grounding resistance: C(H)-E、P(S)-ESBetween each portAC 280V/3second |
|||
|
insulation resistance |
20MΩabove(Between the circuit and the casing500V) |
|||
|
DurablePressure |
AC 3700V/rms(Between the circuit and the casing) |
|||
|
Electromagnetic characteristics |
IEC61326(EMC) |
|||
|
Suitable for safety regulations |
IEC61010-1(CATⅢ 300V、CAT IV 150VPollution level2); IEC61010-031; IEC61557-1(Grounding resistance); IEC61557-5(Soil resistivity); JJG 366-2004. |
|||
|
|
||||
|
Measurement function |
measuring range |
accuracy |
Resolution |
|
|
Grounding resistance(R) |
0.00Ω~30.00Ω |
±2%rdg±3dgt |
0.01Ω |
|
|
30.0Ω~300.0Ω |
±2%rdg±3dgt |
0.1Ω |
|
|
|
300Ω~3000Ω |
±2%rdg±3dgt |
1Ω |
|
|
|
3.00kΩ~30.00kΩ |
±4%rdg±3dgt |
10Ω |
|
|
|
Soil resistivity(ρ) |
0.00Ωm~99.99Ωm |
according toRIt depends on the measurement accuracy(ρ=2πaRa:1 m~100m; π=3.14) |
0.01Ωm |
|
|
100.0Ωm~999.9Ωm |
0.1Ωm |
|
||
|
1000Ωm~9999Ωm |
1Ωm |
|
||
|
10.00kΩm~99.99kΩm |
10Ωm |
|
||
|
100.0kΩm~999.9kΩm |
100Ωm |
|
||
|
1000kΩm~9000kΩm |
1kΩm |
|
||
|
Grounding voltage |
AC 0.0~600V |
±2%rdg±3dgt |
0.1V |
|
3、 Product Features
JC-SR-3100CGrounding resistance·The soil resistivity tester consists of a host, monitoring software, testing line, auxiliary grounding rod, communication line, etc. Simultaneously capable of storing300Group data, through monitoring software to achieve historical query and online real-time monitoring functions, dynamic display, alarm indication, with functions such as historical data reading, viewing, saving, reporting, printing, etc.
Juchuang Environmental Protection provides you with comprehensive technical support and perfect after-sales service! Details consultation:
|
Influence quantity |
Benchmark conditions |
Working conditions |
remarks |
|
|
ambient temperature |
23℃±1℃ |
-10℃~40℃ |
---- |
|
|
Environmental Dampness Crossing |
40%~60% |
<80% |
---- |
|
|
Instrument working voltage |
9V±0.1V |
9V±1.5V |
---- |
|
|
Auxiliary grounding resistance value |
<100Ω |
<30kΩ |
rC、 rP |
|
|
Interference voltage |
nothing |
<20V |
---- |
|
|
Interference current |
nothing |
<2A |
---- |
|
|
measureElectrode spacing at R |
a>5d |
a>5d |
---- |
|
|
measureElectrode spacing at ρ |
a>20h |
a>20h |
---- |
|
|
Gong GongCan |
Measurement of grounding resistance and soil resistivity using two, three, and four wiresMeasurement of grounding voltage and AC voltage |
|||
|
electricSource |
DC 9V (Zinc manganese dry battery R14S 1.5V 6 cells, continuous standby for 300 hours) |
|||
|
amountCheng |
Grounding resistance: 0.00Ω~30.00kΩ |
|||
|
Soil resistivity: 0.00Ωm~9000kΩm |
||||
|
Measurement method |
precise4-wire, 3-wire method measurement, simple 2-wire measurement of grounding resistance |
|||
|
Short circuit test current |
AC 20mA max |
|||
|
Open circuit test voltage |
AC 40V max |
|||
|
Test voltage waveform |
sine wave |
|||
|
Range of electrode spacing |
Can be set1m~100m |
|||
|
changeThe file |
Grounding resistance: 0.00 Ω~30.00k Ω fully automatic shifting |
|||
|
Soil resistivity: 0.00 Ω m~9000k Ω m fully automatic shifting |
||||
|
BackLight |
Controllable blue screen backlight, suitable for use in dark fields |
|||
|
display mode |
4Large LCD display with blue screen backlight |
|||
|
Measurement indication |
Measuring in progressLED flashing, LCD countdown, progress bar chart indication |
|||
|
LCDsize |
128mm×75mm |
|||
|
LCDDisplay Domain |
124mm×67mm |
|||
|
Instrument size |
High, Wide, and Thick: 215mm×190mm×95mm |
|||
|
Standard testing line |
4Strip: Red 20m, Black 20m, Yellow 10m, Green 10m each |
|||
|
Simple testing line |
2Strip: 1 red 1.6m, 1 black 1.6m each |
|||
|
Auxiliary grounding rod |
4Root: 10mm x 150mm |
|||
|
Measurement time |
Ground voltageApproximately 3 times per second |
|||
|
Grounding resistance and soil resistivity: About 5 seconds/time |
||||
|
Measurement frequency |
5000More than once (short circuit test, test once, stop for 30 seconds and then test again) |
|||
|
Line voltage |
AC 600VThe following measurements |
|||
|
RS232Interface |
haveRS232 interface, software monitoring, data storage can be uploaded to the computer, saved and printed |
|||
|
Communication line |
RS2321 communication line, 1.5m long |
|||
|
data storage |
300Group, "MEM" storage indicator, displaying the "FULL" symbol indicates that the storage is full |
|||
|
Data retention |
When maintaining dataThe 'HOLD' symbol indicates |
|||
|
Data retrieval |
When consulting dataThe 'READ' symbol indicates |
|||
|
Overflow display |
When there is an overflow of over rangeThe symbol 'OL' indicates |
|||
|
Interference testing |
Automatically identify interference signals, interference voltage higher thanAt 5V, the "Noise" symbol indicates |
|||
|
Gong GongConsumption |
Standby modeApproximately 20mA (backlight off) |
|||
|
Turn on the backlight when turned onApproximately 45mA (backlight off 25mA) |
||||
|
measureApproximately 100mA (backlight off) |
||||
|
qualityQuantity |
Total Quality: 4.5kg (including packaging) |
|||
|
Working temperature and humidity |
-10℃~40℃; Below 80% RH |
|||
|
Storage temperature and humidity |
-20℃~60℃; Below 70% RH |
|||
|
overload protection |
Measure the grounding resistance: AC 280V/3 seconds between ports C (H) - E and P (S) - ES |
|||
|
insulation resistance |
20MΩAbove (500V between circuit and casing) |
|||
|
DurablePressure |
AC 3700V/rms(Between the circuit and the casing |
|||
|
Electromagnetic characteristics |
IEC61326(EMC) |
|||
|
Suitable for safety regulations |
IEC61010-1(CATIII 300V CAT IV 150V、 Pollution level 2); IEC61010-031; IEC61557-1 (Grounding Resistance); IEC61557-5 (soil resistivity); JJG 366-2004。 |
|||
|
|
||||
|
Measurement function |
measuring range |
accuracy |
Resolution |
|
|
Grounding resistance(R) |
0.00Ω~30.00Ω |
±2%rdg±3dgt |
0.01Ω |
|
|
30.0Ω~300.0Ω |
±2%rdg±3dgt |
0.1Ω |
|
|
|
300Ω~3000Ω |
±2%rdg±3dgt |
1Ω |
|
|
|
3.00kΩ~30.00kΩ |
±4%rdg±3dgt |
10Ω |
|
|
|
Soil resistivity(ρ) |
0.00Ωm~99.99Ωm |
according toThe measurement accuracy of R depends on (ρ=2 π aRa: 1m~100m; π=3.14) |
0.01Ωm |
|
|
100.0Ωm~999.9Ωm |
0.1Ωm |
|
||
|
1000Ωm~9999Ωm |
1Ωm |
|
||
|
10.00kΩm~99.99kΩm |
10Ωm |
|
||
|
100.0kΩm~999.9kΩm |
100Ωm |
|
||
|
1000kΩm~9000kΩm |
1kΩm |
|
||
|
Grounding voltage |
AC 0.0~600V |
±2%rdg±3dgt |
0.1V |
|
JC-SR-3100CGrounding resistance·The soil resistivity tester consists of a host, monitoring software, testing line, auxiliary grounding rod, communication line, etc. Simultaneously capable of storing300Group data, through monitoring software to achieve historical query and online real-time monitoring functions, dynamic display, alarm indication, with functions such as historical data reading, viewing, saving, reporting, printing, etc.