1、 Product Overview
Can be used for small traffic/Medium traffic/high trafficTSPSampler, dust samplerSVOCSFlow and pressure calibration of corresponding range instruments such as samplers, fluoride samplers, microbial samplers, and smoke samplers.
2、 Execution standards
HJ/T368-2007Technical requirements and testing methods for orifice flow meters used in calibrating total suspended particulate matter samplers
JJG633-2005Gas volumetric flowmeter
3、 Main features
Adopting industrial grade5A high-resolution color LCD touch screen with Chinese icon display, which can be used to view the schematic diagram and connection instructions of the gas path through the help files in the instrument, making it easy to operate; equipRS232andUSBInterface, data can be transferred via USB, can be connected to an external thermal printer
Large flow orifice flowmeterSVOCSOrifice flowmeter, medium flow orifice flowmeter, small flow orifice flowmeter, micro pressure gauge, gauge pressure gauge6Calibration function; Users can choose different configurations according to their needs; Calibration instrument usageARMTechnology, fast, accurate measurement, strong anti-interference ability
Automatically detect whether the differential pressure sensor, ambient temperature sensor, and atmospheric pressure sensor are normal when turned on
WiFiFunction, calibrator turned onWiFiServer function: When performing flow calibration, the calibrator automatically sends the measured environmental temperature, flow rate, micro pressure, gauge pressure and other data to the connected client, providing data for the automatic calibration function of the calibrated instrument
Environmental parameters can be manually inputted or automatically measured
Automatically display operating flow rate and standard flow rate(0℃,101.325kPa)Standard flow rate(20℃,101.325kPa)Reference flow rate, operating condition volume, standard condition volume(0℃,101.325kPa), standard condition volume(20℃,101.325kPa)Reference volume, atmospheric pressure, ambient temperature, orifice pressure difference, and other numerical values
Real time curve display for measuring flow rate, micro pressure, and gauge pressure, making pressure and flow stability and trends clear at a glance
Calibration parameters have automatic saving and factory reset functions
Built in large capacity lithium battery for continuous operation of the instrument12hour
Optional national metrology department calibration certificate can be provided to ensure the accuracy of instrument flow calibration
4、 Technical parameters
|
serial number |
parameter name |
measurement range |
resolution |
accuratedegree |
|
1 |
Large flow orifice flowmeter |
(0.700~1.400)m3/min |
0.001 m3/min |
Better than ±1% |
|
2 |
SVOCSLarge flow orifice flowmeter |
(150.0~800.0)L/min |
0.1 L/min |
Better than ±1% |
|
3 |
Medium flow orifice flowmeter |
(70.00~140.00)L/min |
0.01L/min |
Better than ±1% |
|
4 |
Small flow orifice flowmeter |
(10.00~70.00)L/min |
0.01 L/min |
Better than ±1% |
|
5 |
Micro pressure gauge |
(-3000~3000)Pa |
1Pa |
Better than ±1% |
|
6 |
Pressure gauge |
(-30~30)KPa |
0.01kPa |
Better than ±1% |
|
7 |
atmospheric pressure |
(50~115)KPa |
0.01kPa |
Better than ±1% |
|
8 |
battery voltage |
DC12V,1.5AHlithium battery |
||
|
9 |
power |
2.5W |
||
|
10 |
volume |
Length × Width × Height=(178mm×135mm×60mm) |
||
|
11 |
weight |
0.5kg |
||
The product content meets the requirements of relevant national standards. Due to product upgrades or discrepancies between pictures and actual machines, please refer to the actual machine for accuracy,This content is for reference only.