Phone
15588680396
-
Address
No. 23, Siliu North Road, Licang District, Qingdao City
Qingdao Juchuang Environmental Protection Group Co., Ltd
15588680396
No. 23, Siliu North Road, Licang District, Qingdao City
1、 Product Overview
The instrument is particularly suitable for environmental monitoring, public security, and transportation departments to conduct road inspection sampling; Testing departments, industrial and mining enterprises, and remote areas without power sources can all use it. It has the advantages of being able to detect at any time, in real-time, without being affected by any location, and with or without power supply. The instrument is equipped with a refined aluminum alloy suitcase shell, which is easy to carry and operate.
IIexecution standard
GB18285-2018Limits and Measurement Methods for Exhaust Pollutants from Spark Ignition Engine Vehicles (Dual Idle Method and Simple Operating Condition Method)
JT/T386-2004Technical Specifications for Automotive Emission Gas Testers
3、 Main features
Using LCD display and Chinese (or English) menu, it can displayHCTheCOTheCO2TheO2TheNOx(NO+NO2),COcorAnd data such as speed, oil temperature, flow rate, pressure, etc
Single range, automatic zero calibration; Automatic temperature compensation, automatic oil-water separation
This machine adopts German technologyInfrared detectorO2Sensors andNOXSensor, not afraid of vibration, good stability, high accuracy
Optional fully automatic built-in printer,RS-232/RS485interface(Or analog interface)
There is a self diagnostic function inside the machine, and there will be prompts when there is a fault. The measurement can only continue after the fault is eliminated
The instrument has a time function that can display hours, minutes, and seconds, and print year, month, day, hour, and minute
haveHCResidual inspection, automatic cleaning of gas circuit, gas circuit leakage detection function
During measurement, display the real-time concentration value, end by displaying the average value, and check the displayed MAX and MIN values. Print out the MAX, MIN, and average density values
Can input the license plate number of the car and store it2000Measurement data of vehicles, available for retrieval and printing at any time
It has three measurement methods: single idle measurement, dual idle measurement, and universal measurement
Equipped with speed and oil temperature measurement channels
Built in rechargeable battery for continuous operation8hour
optional220VCharger, car cigarette lighter power plug and battery crocodile clip
4、 Technical parameters
measurement rangeHC:0~10000×10-6(ppm)vol(Gasoline as fuel, n-hexane equivalent)
orC3H8:0-20000×10-6(ppm)vol(Liquefied gas as fuel, propane equivalent)
CO:0~10×10-2(%)vol
CO2:0~20×10-2(%)vol
O2:0~25×10-2(%)vol
NOx:0~5000×10-6(ppm)vol
λ:0.50~3.00
COcor:0~10×10-2(%)vol
Speed:0-9999rpm
Oil temperature:0-150℃
indication errorHC±10×10-6(ppm)vol(error)Or ±5%(relative error)
CO±0.03×10-2(%)vol(error)Or ±5%(relative error)
CO2±0.5×10-2(%)vol(error)Or ±5%(relative error)
O2±0.1×10-2(%)vol(error)Or ±5%(relative error)
NOx±25×10-6(ppm)vol(error)Or ±4%(relative error)
Satisfying one of the requirements in the above errors is sufficient.
repetitiveness Repetitive error≤±2%
stability Automatic zero calibration, torque drift≤±3%
resolutionHC:1×10-6(ppm)vol
CO:0.01×10-2(%)vol
CO2:0.1×10-2(%)vol
O2:0.01×10-2(%)vol
NOx:1×10-6(ppm)vol
λ:0.01
Speed:10rpm
Oil temperature:0.1℃
service life The lifespan of oxygen sensors and nitrogen oxygen sensors in air is two years and14Months (accurate beyond the deadline)
The degree will decrease)
response time95%Response not greater than10second
warm-up time8min(Can be preheated)3minEmergency testing)
environmental conditions temperature-5~50℃, relative humidity ≤90%
power supply Built in battery for direct power supply
By carDC12VDirectly powered for use (without the need for any power inverters)
AC100-240V 50/60HZPower supply usage
power consumption<50VA
Overall dimensions520mm(long)×360mm(wide)×250mm(tall)
The product content meets the requirements of relevant national standards. Due to product upgrades or discrepancies between pictures and actual machines, please refer to the actual machine for accuracy,This content is for reference only.
Contact number: 175-5423-8238