1、 Product Overview
The JCY-7031 portable flue gas preprocessor adopts a high-power compressor cooler, which can quickly condense and remove the moisture in the flue gas, minimize the influence of moisture on the flue gas detection results, effectively improve the measurement accuracy of the flue gas analyzer, and extend the service life of the instrument. The whole machine adopts a high-precision controller, which has the characteristics of simple operation, fast dehydration speed, and small loss of flue gas components, and meets the requirements of national standards for flue gas sampling.
2、 Scope of application
This product is widely used for flue gas pretreatment before flue gas analysis and measurement, especially suitable for collection pretreatment in high humidity, low sulfur, ultra-low emission and other working conditions,Widely used in departments such as environmental protection, health, labor, safety supervision, scientific research, and education.
3、 Adopting standards
HJ/T 47-1999Technical Conditions for Smoke Samplers
4Technical Features
1)Using a high-power compressor for cooling, the cooling speed is fast, the cooling efficiency is high, and the cooling temperature can reach-10℃。
2) The sampling pipeline is fully heated to completely avoid condensation loss of flue gas in the sampling pipeline
3) The inner wall of the sampling pipeline is made of polytetrafluoroethylene material, effectively avoiding smoke loss caused by adsorption on the inner wall
4) Heating and cooling both use DC low voltage, which is safer and more stable to use.
5)Heating and cooling adoptPIDDual screen control, high temperature control accuracy, easy operation.
6) Built in metal sintering and PTFE two-stage filtration, with high filtration efficiency, protecting the backend analyzer from particle contamination.
7) The sampling gun and heat tracing belt adopt an integrated design, with slim and soft pipelines that are flexible to use.
8) Equipped with an automatic drainage peristaltic pump, the peristaltic pump is externally mounted for easy observation and replacement of pump tubing.
9) The gas and power interfaces are both quick plug type, making on-site use more convenient.
10)Small size, light weight, easy to carry, convenient for on-site use.
5、 Technical indicators
|
Main parameters |
Default temperature setting |
resolution |
accuracy |
|
Heating gun |
120℃(80-160℃ can be set) |
0.1℃ |
Better than ±2℃ |
|
refrigeration |
2℃(-10-10℃ can be set) |
0.1℃ |
Better than ±2℃ |
|
Inlet temperature of flue gas |
≤180℃ |
||
|
MAX flue gas cooling flow rate |
>2L/min |
||
|
Cooling method |
compression refrigeration |
||
|
MAX cooling capacity |
500W |
||
|
export dew point |
≤4℃ ① |
||
|
Operating temperature |
-20℃—50℃ |
||
|
heating time |
≤6minute ② |
||
|
Cooling time |
≤6minute ③ |
||
|
Sampling gun length |
1m(Other sizes can be customized) |
||
|
Length of tropical belt |
2m(Other sizes can be customized) |
||
|
heating voltage |
DC36V |
||
|
Instrument noise |
≤55dB |
||
|
Overall dimensions of the host |
Length x Width x Height(320×200×200)mm |
||
|
Host weight |
about6.0Kg |
||
|
Working power supply |
AC220V±10%/50Hz |
||
|
power consumption |
≤300W |
||