KANE KM 950 Smoke Analyzer, UK (Maintenance Department)
Boiler factories, as well as enterprises such as steel plants, power plants, thermal power plants, chemical plants, environmental monitoring stations, waste treatment plants, oil fields, etc. Mainly measuring atmospheric pollutants nitrogen oxides and sulfur dioxide
3、 KM950 Smoke Analyzer Details:
Suitable for boiler combustion testing and pollution emissions, handheld, fully Chinese display, easy to operate, convenient for on-site use
Can measure O2, SO2, NO, NO2, CO, flue gas temperature, ambient temperature, total efficiency of flue gas pressure
Automatically calculate flue gas flow rate CO2、NOx、 Net efficiency, total loss, net loss, excess air coefficient
Built in dual head powerful vacuum pump ensures normal operation under high negative pressure and fast response time
The CO, SO2, NO, and NO2 sensors can be flexibly combined and easily upgraded. The results show that the percentage concentration, ppm, and mg/m3 can be freely converted, and the measurement alarm limits for different gas components can be set separately. The internal special gas path design minimizes the loss of SO2 and NOx during testing, and automatically corrects sensor cross interference according to the smoke state.
The large screen display and backlight function facilitate the normal use of the instrument in dim conditions. Through pressure measurement, the flow rate of smoke is directly displayed. After turning on, there is no need to press any keys to enter the testing interface directly. It is simple and convenient, and can be used for both AC and DC. It can work continuously for 6 hours on a full charge. Data storage function Infrared remote control printing method, built-in automatic calibration program for users to calibrate themselves, users can customize the printing content
Kane KM 950 Smoke Analyzer, UK
KANE KM 950 Smoke Analyzer, UK (Maintenance Department)
4: Technical parameters:
| measure quantity |
project | resolution | precision | scope |
| O2 CO SO2 NO NO2 Smoke temperature ambient temperature pressure |
0.1% 1ppm 1ppm 1ppm 1ppm 0.1℃ 0.1℃ 0.01mbar |
-0.1%-+0.2% ±20ppm<100ppm,±5%>100ppm ±5ppm<100ppm,>100ppm ±5ppm<100ppm,>100ppm ±5ppm<100ppm,>100ppm 1 ℃± 0.3% reading 1 ℃± 0.3% reading ±0.5% |
0—25% 0—10000ppm 0—5000ppm 0—5000ppm 0—1000ppm 0—1200℃ >Using a high-temperature probe at 600 ℃ 0—50℃ 0-150mbar |
|
| self move plan calculate |
CO2 NOX Net temperature efficiency Void coefficient loss CO/CO2 |
0.1% 1ppm 0.1℃ 0.1% 0.1% 0.1% 0.0001 |
±0.3% ±5ppm<100ppm,±5%>100ppm ± 1 ℃ ± 3% reading ± 1.0% reading ±0.2% ±0.2% ±0.01 |
0- Fuel analysis value 0—6000ppm 0—1100℃ 0—100 0—2885.0% 0—99.0% 0—0.9999 |
| configuration | Standard configuration: Host, 350mm long probe, dust and water filter, charger, portable bag, operation manual Optional: Infrared printer, 1-meter probe (with built-in PTFE tube) Note: Except for O2 (which is a mandatory test item), users can choose 1-3 sensors from SO2, NO, NO2, and CO according to their needs. The measurement range can also be selected, but it is not possible to select the same sensor for two concentrations at the same time. |
|||