Welcome Customer !

Membership

Help

Beijing Wanju Hengxin Technology Co., Ltd
Custom manufacturer

Main Products:

cep-online>Products

Beijing Wanju Hengxin Technology Co., Ltd

  • E-mail

    157133327@qq.com

  • Phone

    15811219199

  • Address

    Building 2, 1st Floor, No. 4 Huoxing Second Street, Tongzhou District, Beijing, China 018

Contact Now

KANE KM 950 Smoke Analyzer, UK (Maintenance Department)

NegotiableUpdate on 05/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
KANE KM 950 flue gas analyzer (maintenance department) for boiler plants, as well as enterprises such as steel plants, power plants, thermal power plants, chemical plants, environmental monitoring stations, waste treatment plants, oil fields, etc. Mainly used for measuring atmospheric pollutants such as nitrogen oxides and sulfur dioxide, KM950 flue gas analyzer details: Suitable for boiler combustion testing and pollution emissions, handheld, fully displayed in Chinese, easy to operate, and convenient for on-site use. It can measure O2, SO2, NO, NO2, CO, flue gas temperature, ambient temperature, total efficiency of flue gas pressure, and automatically calculate flue gas flow rate
Product Details

KANE KM 950 Smoke Analyzer, UK (Maintenance Department)

Boiler factories, as well as enterprises such as steel plants, power plants, thermal power plants, chemical plants, environmental monitoring stations, waste treatment plants, oil fields, etc. Mainly measuring atmospheric pollutants nitrogen oxides and sulfur dioxide
3、 KM950 Smoke Analyzer Details:
Suitable for boiler combustion testing and pollution emissions, handheld, fully Chinese display, easy to operate, convenient for on-site use
Can measure O2, SO2, NO, NO2, CO, flue gas temperature, ambient temperature, total efficiency of flue gas pressure
Automatically calculate flue gas flow rate CO2、NOx、 Net efficiency, total loss, net loss, excess air coefficient
Built in dual head powerful vacuum pump ensures normal operation under high negative pressure and fast response time
The CO, SO2, NO, and NO2 sensors can be flexibly combined and easily upgraded. The results show that the percentage concentration, ppm, and mg/m3 can be freely converted, and the measurement alarm limits for different gas components can be set separately. The internal special gas path design minimizes the loss of SO2 and NOx during testing, and automatically corrects sensor cross interference according to the smoke state.
The large screen display and backlight function facilitate the normal use of the instrument in dim conditions. Through pressure measurement, the flow rate of smoke is directly displayed. After turning on, there is no need to press any keys to enter the testing interface directly. It is simple and convenient, and can be used for both AC and DC. It can work continuously for 6 hours on a full charge. Data storage function Infrared remote control printing method, built-in automatic calibration program for users to calibrate themselves, users can customize the printing content
Kane KM 950 Smoke Analyzer, UK

KANE KM 950 Smoke Analyzer, UK (Maintenance Department)

4: Technical parameters:

measure
quantity
project resolution precision scope
O2
CO
SO2
NO
NO2
Smoke temperature
ambient temperature
pressure
0.1%
1ppm
1ppm
1ppm
1ppm
0.1℃
0.1℃
0.01mbar
-0.1%-+0.2%
±20ppm<100ppm,±5%>100ppm
±5ppm<100ppm,>100ppm
±5ppm<100ppm,>100ppm
±5ppm<100ppm,>100ppm
1 ℃± 0.3% reading
1 ℃± 0.3% reading
±0.5%
0—25%
0—10000ppm
0—5000ppm
0—5000ppm
0—1000ppm
0—1200℃
>Using a high-temperature probe at 600 ℃
0—50℃
0-150mbar
self
move
plan
calculate
CO2
NOX
Net temperature
efficiency
Void coefficient
loss
CO/CO2
0.1%
1ppm
0.1℃
0.1%
0.1%
0.1%
0.0001
±0.3%
±5ppm<100ppm,±5%>100ppm
± 1 ℃ ± 3% reading
± 1.0% reading
±0.2%
±0.2%
±0.01
0- Fuel analysis value
0—6000ppm
0—1100℃
0—100
0—2885.0%
0—99.0%
0—0.9999
configuration Standard configuration: Host, 350mm long probe, dust and water filter, charger, portable bag, operation manual
Optional: Infrared printer, 1-meter probe (with built-in PTFE tube)
Note: Except for O2 (which is a mandatory test item), users can choose 1-3 sensors from SO2, NO, NO2, and CO according to their needs. The measurement range can also be selected, but it is not possible to select the same sensor for two concentrations at the same time.