LJK φ 80~φ 200 Zero Sequence Current Transformer ZERO SEQUENCE CURRENT TRANSFORMER

NegotiableUpdate on 05/25
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

This series of current transformers is suitable for small grounding current systems indoors, with a rated frequency of 50Hz or 60Hz and a rated voltage of 35kV and below, for three-phase cable grounding protection. It can also be used in conjunction with relays

Product Details

This series of current transformers is suitable for indoor use in small grounding current systems with a rated frequency of 50Hz or 60Hz and a rated voltage of 35kV and below, for three-phase cable grounding protection. It can also be used in conjunction with relays.
During installation, the transformer can be divided into two halves and then merged into one. It can be clamped tightly with a clamp and installed without power interruption.

This series of current transformers is used in indoor small ground current systems with rated frequency 50Hz or 60Hz and rated voltage up to and including 35kV for three-phase cable grounding protection, it also can be used with relay.
The transformer can be divided into two parts during installation, and then they can be combined again and buckled tightly with clamp. It can be installed without power off.

1. Altitude: not exceeding 1000 meters;
2. Environmental temperature: -5 ℃ to+40 ℃;
3. Relative humidity of the air: ≤ 85%;
4. Installation location: Indoor.


1.Altitude should not exceed 1000m;
2.Ambient temperature: -5℃~+40℃;
3.Air relative humidity:≤85%;
4. Installation site: indoor。

1. Rated secondary current: 5A or 1A;
2. Power factor: cos φ=0.8 (lag);
3. Rated frequency: 50Hz or 60Hz;
4. The rated primary current, rated output, and accuracy level are shown in Table 1;

5. Insulation performance; The primary winding can withstand a power frequency withstand voltage of 3kV for 1 minute for the secondary winding and ground, as well as for the secondary winding to ground.

1. Rated secondary current: 5A or 1A;
2. Power factor: cos 中=0.8 (lag) ;
3. Rated frequency: 50Hz or 60Hz;
4.Rated primary current, rated output and accurate level see table 1.,
5.Insulating property: primary winding to secondary winding and ground, and secondary winding to ground can bear the power frequency withstand voltage 3kV for 1min.